SPECTRA OWNER GUIDE

Newport 700 Mk II parts & owner guide

Trace the booster, filter stages, magnetic-drive feed pump and MPC-5000 controls. Use the labeled drawings to identify the component before choosing a replacement or upgrade.

Mk II MPC generation · 24V DC / 110V AC / 220V AC layouts

Have a Newport 1000 Mk II? Open its guide →

Original MPC or a later Mk II-Z / Connect? Choose your generation first.

Your installed system

Separate the main motor supply from the controls and fitted service hardware.

Motor voltage does not identify the board or valve supply.

Identify the pump label before selecting a ratio-specific block or kit.

Standard and commercial cartridge families differ.

Confirm actual dimensions, count and end caps.

Choose only confirmed labels; unknowns do not select an upgrade.

MATCH THE MODULES AND THE INSTALLED GENERATION

Make sure this is your Mk II

Mk II, 2009–2012 manual family

The manufacturer index separates Mk II from original MPC, Mk II-Z and Connect. The February 2012 manual identifies MPC-5000, a separate intake booster, a 240MAG5 main feed head and clear three-piece prefilter bowls. Compare the actual module labels after any retrofit.

Manufacturer generation index ↗

Motor supply and controls are different

The documented DC main motor is 24V. AC machines have a separate DC controls inlet and VFD motor output. The DC parts drawing also names a 12V DC/DC converter. Read what actually reaches the board and valves; a motor label alone must not select a controls kit or solenoid.

DC layout ↗ · AC / separate DC layout ↗ · Converter callout ↗

Trace the functions, not just appearance

The boost pump primes the feed path. Fine filters protect the main magnetic-drive pump. The Clark Pump recovers pressure energy, and the membrane separates product water from brine. The salinity probe and diversion valve decide which product water reaches the tank.

Mk II system plumbing ↗

DIMENSIONS AND HOUSING FAMILIES

Filters: follow the Mk II flow path

Main Mk II diagram: sea strainer → boost pump → 20-micron filter → 5-micron filter → magnetic-drive main feed pump → Clark Pump / membranes. The carbon cartridge belongs to freshwater flushing.

StagePart and nominal sizePurpose / installed location
First fine sedimentFT-FTC-20
10 in long × 2.5 in diameter
After the booster; before the 5-micron cartridge and main feed pump.
Second fine sedimentFT-FTC-5
10 in long × 2.5 in diameter
After the 20-micron cartridge; before the 240MAG5 feed head.
Freshwater-flush carbonFT-FTC-CC
10 in long × 2.5 in diameter
Separate domestic flush path; protects the membrane from chlorine.

These are nominal cartridge dimensions, not a measured end-to-end tolerance. Match end style and actual housing after modifications. Clear bowl shape alone does not establish every cartridge or seal.

A commercial upgrade changes the cartridge family

Commercial dual-filter upgrade kit is an optional retrofit. Confirm module, space, mounting, hoses and current contents with Spectra. Its 20-micron / 5-micron Big Blue candidates are a different diameter family from the standard cartridges; confirm actual measured diameter and ends before ordering.

A housing’s 10¾-inch label in the matrix is not its cartridge length. Do not select a 20-inch Big Blue element just because a seal or wrench code contains 20BB.

Manufacturer upgrade listing ↗

An older 50-micron bulletin is not a new-stage instruction

The appended PF-4 bulletin dated June 2004 mentions a 50-micron element before the booster. The main Mk II diagram and labeled parts page do not identify that additional housing. Confirm the actual fitted intake and current arrangement with Spectra before adding or omitting a stage.

Exact 50-micron or oil/water element dimensions are not independently specified here; provide measured length, diameter and end style for confirmation.

Dated PF-4 bulletin ↗

Oil/water equipment is optional

Oil/water element appears in the spares list, which does not specify its retrofit plumbing. Confirm the fitted separator housing and approved placement with Spectra. Do not remove the 20-then-5 pair from an assumed older-system substitution instruction.

Mk II spares references ↗
Spectra Manufacturer filter, housing, seal and wrench matrix, PDF page 1

Manufacturer filter, housing, seal and wrench matrix

Use the exact column for the installed housing family. Cartridge nominal sizes and physical housing length are different measurements.

Open full-size source ↗

MATCH THE INSTALLED ELEMENT AND VESSEL

Membrane element versus vessel hardware

One replacement kit means one element

KIT-MB-40F supplies one confirmed 2.5 × 40-inch element and replacement seals. The shared Mk II illustrations show both two- and three-vessel arrangements without an explicit model-specific element-size/count table. Confirm actual dimensions, count and membrane labels with Spectra; a full-system quantity is not chosen automatically.

Later Newport 700 layouts use 2 long elements, which is a comparison reference, not proof of an older modified module.

Manufacturer single-element kit ↗

Ring, end plug and brackets are different repairs

Vessel retaining ring is separate from the membrane. The manual labels an older FT-PV-EP end plug; the later end-plug kit requires actual cap/ring/electrode confirmation with Spectra. Bracket ends support the module and are not pressure-vessel plugs.

Optional Z-Brane electrodes need their original fitting and electrical procedure. Do not infer a modern cap conversion from a similar-looking vessel.

Vessel and bracket callouts ↗ · Second vessel illustration ↗

BOOSTER, MAIN HEAD AND DRIVE ARE SEPARATE

Feed pump and power components

Laing boost pump and service connection

Laing intake booster feeds the prefilters; its impeller services that booster, not the vane head. The centrifugal pump must prime below the waterline. The Mk II wiring documents a two-pump/four-wire layout on 12V controls; do not derive order quantity from a current production photo.

Confirm actual pump count, cable pairs, ports and mounting with Spectra.

Placement ↗ · Two-pump wiring ↗ · Booster callouts ↗

240MAG5 magnetic-drive main head

Factory Mk II feed head is named in DC and AC diagrams. Match head stamp, coupling and fittings. It is distinct from the original MPC mechanical-drive 240250 head and the Newport 400 140MAG head.

Remanufactured MAG package candidate requires current package and core-term confirmation with Spectra; it does not automatically include motor, drive or booster.

DC head ↗ · AC head ↗

AC motor nameplate takes precedence

Page 62 names a three-quarter-HP three-phase motor and separate 110/220-input VFDs; page 63 instead labels a 1.5HP motor in a shared photo. Confirm installed motor, VFD, frame and coupling with Spectra before using the 3/4HP link.

The VFD produces three-phase motor power. Boat AC input voltage is not a direct replacement-motor connection instruction.

AC electrical labels ↗ · Alternate motor photo ↗

CONTROLLER GENERATION AND ACTUAL SUPPLY

Salinity probe and MPC upgrade paths

This Mk II manual documents MPC-5000 and a legacy SP3 probe, which is now obsolete. Read the installed board chip before selecting SP4. The MPC-3000 conversion is only for an actually identified earlier or changed control box; a factory Mk II does not need that conversion merely because its probe is obsolete. SP1 is obsolete; SP4 alone does not work on MPC-3000.

Identify the installed controller.

Confirmed MPC-3000 conversion

Identify the DC control supply, including the separate supply on AC versions. The AC motor label does not select the conversion kit.

12V DC controls: Review the 12V MPC conversion

Confirm the installed Newport motor/controller, wiring re-termination and system programming with Spectra. The kit includes A40 board, SP4, Rotoflo and fittings; the 24V kit also includes a 12V flush solenoid.

24V DC controls: Review the 24V MPC conversion

Confirm the installed Newport motor/controller, wiring re-termination and system programming with Spectra. The kit includes A40 board, SP4, Rotoflo and fittings; the 24V kit also includes a 12V flush solenoid.

No conversion kit is selected until the DC control supply is identified.

The existing MPC display is retained. A40’s lowered flush output may change the required solenoid. This is a controls conversion, not a feed-pump or motor upgrade.

MPC-5000 B-series / A31

Spectra lists A40 board plus SP4 probe. Confirm wiring and system programming. The standalone board is not the whole MPC-3000 conversion.

MPC-5000 A34 / A35

SP4 needs the EL-MPC-SPCBA daughter board, or the A40 board plus SP4 route. The daughter board has no exact listing in this catalog. Confirm its availability and the actual interface with Spectra; the probe alone is insufficient.

MPC-5000 A36 / A37 / A39 / A40

SP4 is listed as compatible. Match actual connector and 15-foot cable reach. A36 is listed with or without the daughter board. The shorter SP4N suffix remains a separate confirmation.

Installed controlsCurrent routeBefore ordering
MPC-3000Eligible MPC-5000 conversion firstConfirm DC controls supply, wiring, motor interface and kit contents with Spectra.
MPC-5000 B## / A31A40 board plus SP4Confirm system programming and wiring.
MPC-5000 A34 / A35SP4 with daughter board, or A40 plus SP4Daughter board is required for the retained-board path.
MPC-5000 A36 / A37 / A39 / A40SP4 compatibleCheck exact connector, cable reach and actual chip.
Unknown / unlisted chipNo automatic recommendationIdentify the installed board with Spectra.

After the complete installation, use the calibration procedure for the installed controller and compare with a calibrated independent salinity meter. The Mk II manual calibrates salinity through the MPC software/display against an independent meter. A controller conversion may change the calibration and programming procedure.

Mk II salinity calibration ↗ · Current chip / probe table ↗ · Current conversion contents ↗ · Wiring conversion instructions ↗

MATCH THE BODY AND THE ELECTRICAL OUTPUT

Intake, flush and product-diversion valves

The factory Mk II drawing names INT. Select later bodies by the actual hole pattern and solenoid opening; the year or a Z suffix alone does not identify preservation equipment.

Actual intake bodyManufacturer chart referenceRequired check
5 fitting holes; about 1-inch openingSUB-NP-MK2-INTMatch actual valve, adapter, mounting and fittings with Spectra.
6 fitting holes; about 1-inch openingSUB-NP-MK2-INEZMatch actual valve, adapter, mounting and fittings with Spectra.
6 fitting holes; about 3/4-inch Spartan openingSUB-NP-MK2-INTZMatch actual valve, adapter, mounting and fittings with Spectra.
Spectra Newport intake manifold selector, PDF page 1

Newport intake manifold selector

Count external fitting holes and identify the solenoid opening and required adapter before selecting a body.

Open full-size source ↗
Current flush / diversion replacement chart ↗

THE INSTALLED RATIO SETS THE SERVICE FAMILY

Clark Pump outside and internal parts

Confirm the installed ratio before ordering. The shared manual’s shipping list and membrane module photos name 20%, but its exterior drawing labels CB15 for Newport 700 and CB20 for Newport 1000. These labels conflict for the 700.

If your pump is actually labeled 15%, the historical CB15 block candidate requires Spectra confirmation of serial number, block, inserts and approved service route. The 20% internals and kits below are not presented as substitutes for it.

Shipping list ↗ · Historical block labels ↗

20% top end: one-inch bores

A / B blocks use the current one-inch HP-TB-VSP1 spool piston / seal pair. Old 10VS20 / VSP20 labels require revision confirmation. The larger 7%/10% A1/B1 family is excluded.

Current piston / seal reference ↗

Compare rebuild, seal and offshore kit contents

20% distributor rebuild kit excludes spacer rings and top-end spool pistons. 20% seal/O-ring kit has a different scope. 20% offshore kit includes tools and cleaners but excludes rods and cylinder pistons.

Confirm actual ratio and current contents with Spectra before ordering overlapping loose pieces. The older generic offshore code is not the current 7%/10% kit.

LOCATE THE COMPONENT BEFORE CHOOSING A PART

Labeled Mk II assembly drawings

Choose a section; open a drawing for full-size manufacturer callouts. These are the actual published illustrations. Historical conflicts and current 20% revision checks remain next to the drawing.

Showing all Mk II assembly drawings.

Spectra Mk II seawater and flush plumbing, PDF page 10

Mk II seawater and flush plumbing

The booster feeds the 20-then-5 micron prefilter pair before the magnetic-drive main pump. The carbon flush path is separate.

Open full-size source ↗
Spectra Two-vessel example and standard prefilter module, PDF page 59

Two-vessel example and standard prefilter module

Clear three-piece filter bowls hold the 20- and 5-micron cartridges. The shared vessel photo is an identification example, not a model-specific order quantity.

Open full-size source ↗
Spectra Carbon freshwater-flush housing and regulator, PDF page 60

Carbon freshwater-flush housing and regulator

Identify the carbon element, three-piece bowl and flush-water regulator independently of seawater filtration.

Open full-size source ↗
Spectra Three-vessel example and Laing boost-pump module, PDF page 58

Three-vessel example and Laing boost-pump module

The lower drawing identifies the boost pump and service valve. Verify actual booster count and wiring; the upper shared picture does not set membrane quantities.

Open full-size source ↗
Spectra 24V DC main-feed wiring layout, PDF page 15

24V DC main-feed wiring layout

One-HP motor and its high-current speed control are separate from MPC controls. Identify any DC/DC converter and actual control supply.

Open full-size source ↗
Spectra AC input, separate DC controls and boost-pump cable, PDF page 16

AC input, separate DC controls and boost-pump cable

AC input feeds a VFD with three-phase motor output. The drawing specifically notes a four-wire/two-booster arrangement on 12V control versions.

Open full-size source ↗
Spectra DC motor, MAG5 head, manifold and sensors, PDF page 61

DC motor, MAG5 head, manifold and sensors

EL-SSR-ABS, EL-SSR-250, Rotoflo and legacy SP3 measure different functions. DC motor is one HP; PWMA24 suffix needs current-controller confirmation.

Open full-size source ↗
Spectra AC VFD and motor labels, PDF page 62

AC VFD and motor labels

The AC drawing names a three-quarter-HP three-phase motor; another shared photo names 1.5HP. Confirm the installed motor plate and VFD.

Open full-size source ↗
Spectra Product sensing, diversion and an alternate motor photo, PDF page 63

Product sensing, diversion and an alternate motor photo

This page labels a 1.5HP three-phase motor. Its photo does not override the actual installed motor or establish a universal replacement.

Open full-size source ↗
Spectra Clark Pump outside: historical CB15 / CB20 labels, PDF page 64

Clark Pump outside: historical CB15 / CB20 labels

This page labels CB15 for NP700 and CB20 for NP1000, while the shipping list and module photos name 20%. Confirm the actual ratio before choosing a block or kit.

Open full-size source ↗
Spectra Historical reversing-valve callouts, PDF page 65

Historical reversing-valve callouts

Old KIT-HP-10VS20 and VSP20 / PS20 suffixes are not automatically current aliases. For confirmed 20%, use the current one-inch bore/piston/seal reference.

Open full-size source ↗
Spectra Current 20% one-inch spool piston and seal, PDF page 20

Current 20% one-inch spool piston and seal

For confirmed current 20% hardware, HP-TB-VSP1 and SO-HPP-SP1 differ from the larger 7%/10% pair. Match actual bore and revision.

Open full-size source ↗
Spectra Center-block pilot and check-valve locations, PDF page 66

Center-block pilot and check-valve locations

The older generic single-rod drawing does not establish current 20% rod quantity or the internal arrangement of a 15% pump.

Open full-size source ↗
Spectra Current 20% twin-rod arrangement, PDF page 16

Current 20% twin-rod arrangement

The current manufacturer rebuild manual identifies two 7/8-inch rods for 20%. Do not apply this callout to an unconfirmed historical 15% pump.

Open full-size source ↗
Spectra Cylinder, piston and end-cap assembly, PDF page 67

Cylinder, piston and end-cap assembly

PT20 is distinct from the one-piece smaller-ratio piston. Verify the actual piston, seal/bushing pieces and present package contents.

Open full-size source ↗

KEEP ROUTINE SERVICE AND CORRECTIVE REPAIRS SEPARATE

Maintenance and onboard spares

Filters and carbon have different service triggers

Service the fitted sediment stages according to condition and current cartridge instructions. Old wash/reuse advice does not establish that every current element can be washed. Carbon cannot be restored by cleaning; the Mk II manual specifies replacement at least every six months.

Maintenance ↗ · Carbon service bulletin ↗

Storage quantities include retained system water

SC-1 storage compound is for preservation, not membrane cleaning or freeze protection. The Mk II storage procedure uses two containers and accounts for water already in the system. Follow the complete instructions for the installed plumbing; do not mix a bucket dose without the retained-volume calculation.

Storage quantities ↗ · Full pickling procedure ↗

The cruise kit name has a historical mismatch

The Mk II spares page calls the package Basic Cruise Kit B but prints KIT-BCK-C. Confirm current B / C contents with Spectra against your fitted elements and storage supplies. Kit letters alone do not settle this mismatch. Confirm pump ratio before adding an offshore kit.

Spares list ↗

Optional Z-Brane differs from Z-Ion

This Mk II manual describes optional pressure-vessel Z-Brane equipment. A later Z-Ion generator bowl and control retrofit is different hardware. The Z suffix on a modern intake body does not supply the generator or prove a complete conversion. Confirm all preservation equipment with Spectra before using a changed-plumbing service procedure.

Z-Brane section ↗

ANSWERS THAT CHANGE YOUR PART CHOICE

Filter, controller and rebuild questions

What size filters does the standard Mk II use?

The 20- and 5-micron sediment elements and the carbon flush element have manufacturer nominal dimensions of 10 inches long × 2.5 inches diameter. A commercial Big Blue upgrade uses a different diameter family. Match actual ends and bowls; physical housing length is not the cartridge length.

Do I need to add a 50-micron stage?

The main Mk II plumbing shows the booster ahead of the 20/5 pair, but an older dated PF-4 appendix mentions an added 50-micron stage. Confirm the actual fitted inlet equipment and current guidance with Spectra before adding or removing a stage.

Is the Newport 700 always a 20% Clark Pump?

The shared Mk II manual conflicts: shipping/module pages say 20%, while the exterior page labels CB15 for NP700. Use the installed ratio label and Spectra serial-number confirmation. The guide does not treat 15% and 20% blocks or kits as interchangeable.

Does 24V main motor power mean 24V controls or solenoids?

No. The DC diagram includes a 12V converter, and AC versions have a separate DC inlet. Read the actual board supply and valve output before selecting electrical parts. A40 controller conversions may also change flush output.

Does an obsolete SP3 mean I need the MPC-3000 upgrade kit?

The factory Mk II manual specifies MPC-5000. Select the probe/interface path by its actual chip. The MPC-3000 conversion is only for an identified earlier or changed controller, not every old probe.

How many membrane kits should I order?

One KIT-MB-40F replaces one positively identified 2.5 × 40-inch element. Later Newport 700 layouts use 2 elements, but the shared Mk II pictures alone do not establish this installation’s size and count. Confirm the actual module, elements and end caps with Spectra.

Can the Newport 400 motor conversion be used here?

That half-HP conversion is not established for the larger Mk II 700/1000 module. Its DC diagram names a one-HP motor and PWMA24 drive. Confirm exact motor, current rating, coupling and programming with Spectra.

MODEL-SCOPED REFERENCES WITH THEIR REQUIREMENTS

Search parts and researched replacement paths

Named model and current manufacturer references appear first. Changed-hardware candidates remain separate and conditional. A selection does not verify a retrofit, live stock or price.

139 references.

SC-1

Storage Compound

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies SC-1 (Storage Compound) in the Mk II service reference, page 6. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Storage / preservation chemical for Spectra systems. Use the model manual for the required dose, circulation and recommissioning procedure. This is a maintenance consumable, not an installed component or an automatic recommendation to clean. Manufacturer current kit name: KIT-CHEM-SC1; this catalog listing uses SC-1.

Manual, page 6 ↗

View part & current price
SC-2

Alkaline Cleaning Compound

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies SC-2 (Alkaline Cleaning Compound) in the Mk II service reference, page 6. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Alkaline membrane cleaner for biological fouling, compatible with Spectra systems. Use only when cleaning is indicated and follow your model manual for dose, temperature, circulation and flushing. This is a service consumable; do not mix cleaners. Manufacturer current kit name: KIT-CHEM-SC2; this catalog listing uses SC-2.

Manual, page 6 ↗

View part & current price
SC-3

Acid Cleaning Chemical

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies SC-3 (Acid Cleaning Chemical) in the Mk II service reference, page 6. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Acid membrane cleaner for mineral scale, compatible with Spectra systems. Use only when cleaning is indicated and follow your model manual for dose, temperature, circulation and flushing. This is a service consumable; do not mix cleaners. Manufacturer current kit name: KIT-CHEM-SC3; this catalog listing uses SC-3.

Manual, page 6 ↗

View part & current price
EL-MPC-CBL50

50' MPC Remote Controller Cable

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies EL-MPC-CBL50 (50' MPC Remote Controller Cable) in the carbon flush module, page 60. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • 50-foot MPC display cable for the documented legacy controller/display pair. It is not a Spectra Connect Ethernet cable.

Manual, page 60 ↗

View part & current price
EL-SSR-250

Pressure Transducer (250 Psi)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. 250-PSI transducer on the main pump outlet/feed-pressure path, not the absolute-pressure inlet sensor or a 150-PSI Newport 400 sensor. Match range, socket, cable and installed MPC calibration with Spectra before replacing it. The labeled drawing location matters even when two sensors look alike.

Identification requirements & source

250-PSI transducer on the main pump outlet/feed-pressure path, not the absolute-pressure inlet sensor or a 150-PSI Newport 400 sensor. Match range, socket, cable and installed MPC calibration with Spectra before replacing it. The labeled drawing location matters even when two sensors look alike.

Existing fitment requirements

  • legacy pressure-sensor assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match sensor range and installed legacy connector; no automatic modern control conversion.

Manual, page 61 ↗

View part & current price
EL-SSR-ABS

Absolute Pressure Sensor

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Absolute-pressure sensor on the intake manifold; the controller uses inlet information to detect restrictions. It is a different measurement from the 250-PSI main-feed sensor. Match cable, connector and controller calibration with Spectra; do not substitute the pressure range by appearance.

Identification requirements & source

Absolute-pressure sensor on the intake manifold; the controller uses inlet information to detect restrictions. It is a different measurement from the 250-PSI main-feed sensor. Match cable, connector and controller calibration with Spectra; do not substitute the pressure range by appearance.

Existing fitment requirements

  • legacy pressure-sensor assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match sensor range and installed legacy connector; no automatic modern control conversion.

Manual, page 61 ↗

View part & current price
EL-SSR-IFM

Legacy inline flow sensor — confirm range

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Rotoflo product-water flow sensor, separate from pressure and salinity sensing. The Mk II drawing names IFM, not every low-range IFMLR revision. Confirm actual flow range/units, pulse signal, plumbing and installed-board settings with Spectra before ordering. This flow display does not independently establish water quality.

Identification requirements & source

Rotoflo product-water flow sensor, separate from pressure and salinity sensing. The Mk II drawing names IFM, not every low-range IFMLR revision. Confirm actual flow range/units, pulse signal, plumbing and installed-board settings with Spectra before ordering. This flow display does not independently establish water quality.

Existing fitment requirements

  • Standard-range inline sensor in the documented Catalina/Newport product-water module. Match 0.5–5 L/min range and 3/8-inch NPT ports. Replacement EL-SSR-IFM is supplied with bare wires per the 2023 bulletin; Molex-terminated assembly is SUB-MPC-IFA. Match the installed connection before ordering. Standard sensor: 0.5–5 L/min, 3/8-inch NPT; Molex assembly SUB-MPC-IFA. The 2023 marine Connect production change uses a three-pin Deutsch connector; replacement bare-sensor SKU is supplied with bare wires. Do not assume an order arrives with a Deutsch plug.

Manual, page 61 ↗

View part & current price
EL-SWT-TG-DPDT

Toggle Switch DP/DT

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies EL-SWT-TG-DPDT (Toggle Switch DP/DT) in the AC drive/electrical enclosure, page 62. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • item in the identified generation and enclosure. Match switch poles/terminals, boot or enclosure dimensions, and instrument range/connection as applicable. A similar label on another control generation is not a substitution.

Manual, page 62 ↗

View part & current price
EL-TM-1/4PPCP

1/4" Cable Cap Stud Insulator (Black)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies EL-TM-1/4PPCP (1/4" Cable Cap Stud Insulator (Black)) in the 24V DC feed module, page 61. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Original 24V DC feed motor/cable-stud arrangement in this legacy generation; match the actual motor and insulated stud position. System input: 24 V; retain the specified component supply and wiring.

Manual, page 61 ↗

View part & current price
FT-FTC-20

20 Micron Filter

24V DC / 110V AC / 220V AC layout references · standard prefilter arrangement · Named in model manual

Identification requirements & source

First fine-sediment element, after the boost pump and before the 5-micron stage and main magnetic-drive feed pump. Current manufacturer nominal cartridge dimensions: 10 inches long × 2.5 inches diameter. Match actual housing and end style; nominal size is not an exact measured end-to-end tolerance.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 59 ↗

View part & current price
FT-FTC-5

5 Micron Filter

24V DC / 110V AC / 220V AC layout references · standard prefilter arrangement · Named in model manual

Identification requirements & source

Second fine-sediment element, after the 20-micron stage and before the main magnetic-drive feed pump. Current manufacturer nominal cartridge dimensions: 10 inches long × 2.5 inches diameter. Match actual housing and end style; nominal size is not an exact measured end-to-end tolerance.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 59 ↗

View part & current price
FT-FTC-CC

Carbon Filter

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

Carbon element on the independent domestic freshwater-flush path; it removes chlorine before flush water reaches the membrane. Replace at least every six months. Current manufacturer nominal cartridge dimensions: 10 inches long × 2.5 inches diameter. Match actual housing and end style; nominal size is not an exact measured end-to-end tolerance.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 60 ↗

View part & current price
FT-FTC-OW

Oil Water Separator Filter

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Optional oil/water element is named in the Mk II spares list. That list does not establish an installation sequence or exact cartridge dimensions for an added assembly. Confirm the installed separator housing, measured length/diameter, service fittings and approved upstream placement with Spectra. Do not remove the documented 20-then-5 stages from an assumed older procedure.

Identification requirements & source

Optional oil/water element is named in the Mk II spares list. That list does not establish an installation sequence or exact cartridge dimensions for an added assembly. Confirm the installed separator housing, measured length/diameter, service fittings and approved upstream placement with Spectra. Do not remove the documented 20-then-5 stages from an assumed older procedure.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 6 ↗

View part & current price
FT-FTH-10L3PCS

10" Low Press. Filter Housing 3 Pcs

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The Mk II main prefilters and separate carbon flush unit use clear three-piece FT-FTH-10L3PCS housings. The manufacturer matrix pairs this family with SO-FHS-3PCS10 seals and FT-FHW-3PCS wrench. Identify the actual ring/bowl; a black 10H or Big Blue housing uses different service hardware.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Manual, page 59 ↗

View part & current price
FT-PV-ER

Membrane Ring

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Membrane vessel retaining hardware is separate from the replacement element. Mk II diagrams label the older FT-PV-EP end plug and FT-PV-ER ring; optional Z-Brane electrodes use dedicated end-plug fittings. Confirm actual plug, retaining ring and electrode revision with Spectra before using the later KIT-PV-25EP1 route. A mounting-bracket end is another part.

Identification requirements & source

Membrane vessel retaining hardware is separate from the replacement element. Mk II diagrams label the older FT-PV-EP end plug and FT-PV-ER ring; optional Z-Brane electrodes use dedicated end-plug fittings. Confirm actual plug, retaining ring and electrode revision with Spectra before using the later KIT-PV-25EP1 route. A mounting-bracket end is another part.

Manual, page 58 ↗

View part & current price
EL-BRK-15ADP

15A Double-Pole AC/DC Breaker

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies EL-BRK-15ADP (15A Double-Pole AC/DC Breaker) in the AC drive/electrical enclosure, page 62. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • 15A double-pole breaker specified for the legacy 220VAC Mk II/Mk II-Z circuit. Newer Connect breaker assignments differ; match the exact electrical generation. System input: 220 V; retain the specified component supply and wiring.

Manual, page 62 ↗

View part & current price
EL-BRK-30ADP

30A Double-Pole AC/DC Breaker

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies EL-BRK-30ADP (30A Double-Pole AC/DC Breaker) in the AC drive/electrical enclosure, page 62. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • 30A double-pole breaker specified for the legacy 110VAC circuit. This legacy assignment must not be copied into newer Connect wiring. System input: 110 V; retain the specified component supply and wiring.
  • The legacy diagram explicitly also assigns the 30A breaker to 24V DC. Match the original Mk II electrical assembly. System input: 24 V; retain the specified component supply and wiring.

Manual, page 62 ↗

View part & current price
EL-TM-30A2

Terminal Block 30A 2 POS.

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies EL-TM-30A2 (Terminal Block 30A 2 POS.) in the AC drive/electrical enclosure, page 62. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Two-position terminal block in the older Mk II AC layout. This is a different diagram generation from Mk II-Z and Connect. System input: 110/220 V; retain the specified component supply and wiring.

Manual, page 62 ↗

View part & current price
FT-PV-UTC

Pressure Vessel U-Tube Connector

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies FT-PV-UTC (Pressure Vessel U-Tube Connector) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • tube/connector/plug in the illustrated Newport long-vessel assembly. Match the indicated location and installed vessel arrangement. Requires the illustrated standard long-vessel arrangement; compact and altered tube layouts are outside this mapping.

Manual, page 58 ↗

View part & current price
HP-CB-PPS

Pilot Valve Pin

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies HP-CB-PPS (Pilot Valve Pin) in the pilot/check-valve center block, page 66. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies HP-CB-PPS (Pilot Valve Pin) in the pilot/check-valve center block, page 66. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 66 ↗

View part & current price
HP-CB-PVCR

Pilot Valve Clip Ring

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies HP-CB-PVCR (Pilot Valve Clip Ring) in the pilot/check-valve center block, page 66. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies HP-CB-PVCR (Pilot Valve Clip Ring) in the pilot/check-valve center block, page 66. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 66 ↗

View part & current price
HP-CB-PVS

Pilot Valve Spool

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies HP-CB-PVS (Pilot Valve Spool) in the pilot/check-valve center block, page 66. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies HP-CB-PVS (Pilot Valve Spool) in the pilot/check-valve center block, page 66. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 66 ↗

View part & current price
HP‐CYL‐CCA

Cylinder Assembly (G‐10 BASE)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies HP-CYL-CCA (Cylinder Assembly (G‐10 BASE)) in the Clark Pump exterior, page 64. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies HP-CYL-CCA (Cylinder Assembly (G‐10 BASE)) in the Clark Pump exterior, page 64. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 64 ↗

View part & current price
HP‐CYL‐EC

Cylinder End Cap

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies HP-CYL-EC (Cylinder End Cap) in the Clark Pump exterior, page 64. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies HP-CYL-EC (Cylinder End Cap) in the Clark Pump exterior, page 64. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 64 ↗

View part & current price
HP‐CYL‐R

Cylinder End Ring

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies HP-CYL-R (Cylinder End Ring) in the cylinder assembly, page 67. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies HP-CYL-R (Cylinder End Ring) in the cylinder assembly, page 67. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 67 ↗

View part & current price
HP-CYL-SST

Stainless Tube

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies HP-CYL-SST (Stainless Tube) in the Clark Pump exterior, page 64. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies HP-CYL-SST (Stainless Tube) in the Clark Pump exterior, page 64. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 64 ↗

View part & current price
HP‐TB‐BV

Bleed Valve

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies HP-TB-BV (Bleed Valve) in the Clark Pump exterior, page 64. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies HP-TB-BV (Bleed Valve) in the Clark Pump exterior, page 64. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 64 ↗

View part & current price
HP‐TB‐VB

Valve Body

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies HP-TB-VB (Valve Body) in the Clark Pump exterior, page 64. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies HP-TB-VB (Valve Body) in the Clark Pump exterior, page 64. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 64 ↗

View part & current price
PL-BSH-1/2X3/8N

Fitting 1/2" x 3/8" Hex Bushing Reducer Nylon PL-BHF-3/8TPIEJ

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-BSH-1/2X3/8N (Fitting 1/2" x 3/8" Hex Bushing Reducer Nylon PL-BHF-3/8TPIEJ) in the membrane and prefilter module, page 59. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Manual, page 59 ↗

View part & current price
PL-BSH-3/4X1/4N

3/4" X 1/4" Hex Bushing Reducer Nyl

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-BSH-3/4X1/4N (3/4" X 1/4" Hex Bushing Reducer Nyl) in the carbon flush module, page 60. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 60 ↗

View part & current price
PL-FHB-1/2X3/4E

Nylon Hose Barb Elbow, 1/2 in FPT x 3/4 in Barb

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-FHB-1/2X3/4E (Nylon Hose Barb Elbow, 1/2 in FPT x 3/4 in Barb) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Manual, page 58 ↗

View part & current price
PL-FTE-1/8X1/4P

1/8" Female NPT x 1/4" Tube Elbow Fitting

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-FTE-1/8X1/4P (1/8" Female NPT x 1/4" Tube Elbow Fitting) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • tube/connector/plug in the illustrated Newport long-vessel assembly. Match the indicated location and installed vessel arrangement. Requires the illustrated standard long-vessel arrangement; compact and altered tube layouts are outside this mapping.

Manual, page 58 ↗

View part & current price
PL-HBE-3/4X1/2

3/4" Npt X 1/2"Hose Barb Ell. Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-HBE-3/4X1/2 (3/4" Npt X 1/2"Hose Barb Ell. Nylon) in the carbon flush module, page 60. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 60 ↗

View part & current price
PL-HBE-3/4X3/4

3/4" Npt X 3/4" Hose Barb Ell Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-HBE-3/4X3/4 (3/4" Npt X 3/4" Hose Barb Ell Nylon) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Manual, page 58 ↗

View part & current price
PL-HBE-7/8SX3/4

7/8"-14S X 3/4" Hose Barb El Ss.

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-HBE-7/8SX3/4 (7/8"-14S X 3/4" Hose Barb El Ss.) in the 24V DC feed module, page 61. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 61 ↗

View part & current price
PL-HBS-1/2X3/4

1/2" Npt X 3/4" Hose Barb St Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-HBS-1/2X3/4 (1/2" Npt X 3/4" Hose Barb St Nylon) in the product-sensing and feed module, page 63. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 63 ↗

View part & current price
PL-HBS-1/4X1/2

1/4" Npt X 1/2" Hose Barb St. Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-HBS-1/4X1/2 (1/4" Npt X 1/2" Hose Barb St. Nylon) in the carbon flush module, page 60. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 60 ↗

View part & current price
PL-HP-1/8

1/8" Hex Plug Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-HP-1/8 (1/8" Hex Plug Nylon) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • tube/connector/plug in the illustrated Newport long-vessel assembly. Match the indicated location and installed vessel arrangement. Requires the illustrated standard long-vessel arrangement; compact and altered tube layouts are outside this mapping.

Manual, page 58 ↗

View part & current price
PL-HS-3/4VN

3/4" Vinyl Hose

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-HS-3/4VN (3/4" Vinyl Hose) in the 24V DC feed module, page 61. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Length is not established; measure the run and retain the specified hose/tube duty.

Manual, page 61 ↗

View part & current price
PL-MTE-1/2X5/8P

Pl-Mte-1/2X5/8P

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-MTE-1/2X5/8P (Pl-Mte-1/2X5/8P) in the membrane and prefilter module, page 59. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 59 ↗

View part & current price
PL-MTE-3/4S1/2B

Pl-Mte-3/4S1/2B

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-MTE-3/4S1/2B (Pl-Mte-3/4S1/2B) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Original bronze elbow with 3/4-16 straight-thread end and half-inch tube connection, as pictured in this legacy assembly. Do not alias to KIT-MTE-3/4SX1/2SL or infer a current stainless replacement from dimensions alone.

Manual, page 58 ↗

View part & current price
PL-MTE-3/4X5/8P

Pl-Mte-3/4X5/8P

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-MTE-3/4X5/8P (Pl-Mte-3/4X5/8P) in the membrane and prefilter module, page 59. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 59 ↗

View part & current price
PL-MTE-3/8X3/8J

John Guest Elbow, 3/8 in NPT x 3/8 in Tube

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-MTE-3/8X3/8J (John Guest Elbow, 3/8 in NPT x 3/8 in Tube) in the membrane and prefilter module, page 59. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 59 ↗

View part & current price
PL-MTS-1/4X1/4P

1/4" Male NPT x 1/4" Tube Straight

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-MTS-1/4X1/4P (1/4" Male NPT x 1/4" Tube Straight) in the carbon flush module, page 60. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 60 ↗

View part & current price
PL-MTS-3/8X1/2S

Pl-Mts-3/8X1/2S

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-MTS-3/8X1/2S (Pl-Mts-3/8X1/2S) in the cylinder assembly, page 67. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Manual, page 67 ↗

View part & current price
PL-NP-1/2X3/8N

1/2"Npt X 3/8"Npt Close Nipple Nyl

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-NP-1/2X3/8N (1/2"Npt X 3/8"Npt Close Nipple Nyl) in the membrane and prefilter module, page 59. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 59 ↗

View part & current price
PL-NP-1/4N

Pl-Np-1/4N

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-NP-1/4N (Pl-Np-1/4N) in the carbon flush module, page 60. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 60 ↗

View part & current price
PL-NP-1/8N

1/8"Npt Close Nipple Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-NP-1/8N (1/8"Npt Close Nipple Nylon) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • tube/connector/plug in the illustrated Newport long-vessel assembly. Match the indicated location and installed vessel arrangement. Requires the illustrated standard long-vessel arrangement; compact and altered tube layouts are outside this mapping.

Manual, page 58 ↗

View part & current price
PL-NP-3/4N

3/4" Npt Close Nipple Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-NP-3/4N (3/4" Npt Close Nipple Nylon) in the membrane and prefilter module, page 59. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Manual, page 59 ↗

View part & current price
PL-PRG-1/4P

1/4" Water Pressure Regulator

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-PRG-1/4P (1/4" Water Pressure Regulator) in the carbon flush module, page 60. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 60 ↗

View part & current price
PL-QDC-BD3/8

3/8"Npt Quick Discnt. Coup. Body

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-QDC-BD3/8 (3/8"Npt Quick Discnt. Coup. Body) in the membrane and prefilter module, page 59. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Manual, page 59 ↗

View part & current price
PL-SLN-1/4D12M

1/4" Diversion Valve 12 V (Mnf)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Product-water diversion valve/manifold reference, separate from intake and freshwater flush. The Mk II drawing names a 12V D12M valve; later Spartan and Burkert conversion routes differ in body, output and fittings. Confirm actual valve, MPC output and conversion contents with Spectra; 24V main-feed power does not establish a 24V diversion coil.

Identification requirements & source

Product-water diversion valve/manifold reference, separate from intake and freshwater flush. The Mk II drawing names a 12V D12M valve; later Spartan and Burkert conversion routes differ in body, output and fittings. Confirm actual valve, MPC output and conversion contents with Spectra; 24V main-feed power does not establish a 24V diversion coil.

Existing fitment requirements

  • Requires the matching Burkert manifold and 12V solenoid specification. Confirm the installed assembly and voltage.

Manual, page 61 ↗

View part & current price
PL-UNN-1/2N

1/2"Fpt Coupler Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-UNN-1/2N (1/2"Fpt Coupler Nylon) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Manual, page 58 ↗

View part & current price
EL-FP-BPLDC824

300-1K Boost Pump 12/24Vdc 1/2"Npt

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Laing intake boost pump ahead of the 20/5 prefilters, separate from the 240MAG5 main feed pump. The drawing names an 8–24VDC pump; the wiring section also shows a two-pump/four-wire arrangement for 12VDC controls. Current production uses two pumps, which is not proof of every Mk II package quantity. Confirm actual pump count, supply, cable pairs, mounting and ports with Spectra; the centrifugal booster must prime below the waterline.

Identification requirements & source

Laing intake boost pump ahead of the 20/5 prefilters, separate from the 240MAG5 main feed pump. The drawing names an 8–24VDC pump; the wiring section also shows a two-pump/four-wire arrangement for 12VDC controls. Current production uses two pumps, which is not proof of every Mk II package quantity. Confirm actual pump count, supply, cable pairs, mounting and ports with Spectra; the centrifugal booster must prime below the waterline.

Existing fitment requirements

  • Original single Laing 8–24V boost-pump module. Match installed pump supply and half-inch NPT ports. Later dual-boost assemblies are a different module.

Manual, page 58 ↗

View part & current price
EL-MTR-1D24

One-HP 24V DC main-feed motor

24V DC feed-power candidate · Named in model manual

Confirm with Spectra before ordering. Named Mk II DC main-feed motor: one HP, 24V DC, 1800 RPM, TEFC 56C. Match actual manufacturer plate, shaft/frame and magnetic-drive coupling with Spectra. The drawing separately names EL-MTR-PWMA24; the motor listing does not include that controller. The Newport 400 half-HP motor conversion is not a replacement route for this larger module.

Identification requirements & source

Named Mk II DC main-feed motor: one HP, 24V DC, 1800 RPM, TEFC 56C. Match actual manufacturer plate, shaft/frame and magnetic-drive coupling with Spectra. The drawing separately names EL-MTR-PWMA24; the motor listing does not include that controller. The Newport 400 half-HP motor conversion is not a replacement route for this larger module.

Existing fitment requirements

  • Original 24V DC feed motor/cable-stud arrangement in this legacy generation; match the actual motor and insulated stud position. System input: 24 V; retain the specified component supply and wiring.

Manual, page 61 ↗

View part & current price
EL-MTR-3/4AC220

3/4 Hp, 240 Vac, 3 Phase, 56C Motor

110V / 220V AC feed-power layouts · Named in model manual

Confirm with Spectra before ordering. AC electrical drawing names a three-quarter-HP 240VAC three-phase 56C motor with EL-MTR-SPCAC110/220 VFDs. Another shared photo on page 63 labels a 1.5HP three-phase motor. Confirm installed motor plate, VFD, frame and coupling with Spectra before selecting this 3/4HP link. The 110/220V boat input is not the motor output; never connect this three-phase motor directly to single-phase mains.

Identification requirements & source

AC electrical drawing names a three-quarter-HP 240VAC three-phase 56C motor with EL-MTR-SPCAC110/220 VFDs. Another shared photo on page 63 labels a 1.5HP three-phase motor. Confirm installed motor plate, VFD, frame and coupling with Spectra before selecting this 3/4HP link. The 110/220V boat input is not the motor output; never connect this three-phase motor directly to single-phase mains.

Existing fitment requirements

  • 240V three-phase motor driven by the documented AC speed controller. 110/220V system input does not mean the motor connects directly to that input; retain the matching drive. System input: 110/220 V; retain the specified component supply and wiring.

Manual, page 62 ↗

View part & current price
PL-PMP-240MAG5

240MAG5 magnetic-drive feed-pump head

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

Factory Mk II 240MAG5 magnetic-drive feed-pump head, named in both DC and AC module drawings. This head is separate from the booster, motor and PWM/VFD drive. Match the installed C250 head stamp, magnetic coupling and inlet/outlet fittings; do not substitute the mechanically coupled original-MPC 240250 head or a Newport 400 140MAG head.

Existing fitment requirements

  • Installed MAG5 magnetic-drive Newport 700/1000 configuration; excludes older direct drive.
  • MAG5 magnetic-drive feed pump configuration only. Excludes older direct-drive pumps.

Manual, page 61 ↗

View part & current price
PL-TB-HPTPVLL

Hp Pump To Pv Ss. Tube Long (Lower)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-TB-HPTPVLL (Hp Pump To Pv Ss. Tube Long (Lower)) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Existing fitment requirements

  • tube/connector/plug in the illustrated Newport long-vessel assembly. Match the indicated location and installed vessel arrangement. Requires the illustrated standard long-vessel arrangement; compact and altered tube layouts are outside this mapping.

Manual, page 58 ↗

View part & current price
PL-TB-HPTPVUL

Hp Pump To Pv Ss. Tube Long (Upper)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-TB-HPTPVUL (Hp Pump To Pv Ss. Tube Long (Upper)) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Manual, page 58 ↗

View part & current price
HP-CB-PVPS

Pilot Valve Pin Seal

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies HP-CB-PVPS (Pilot Valve Pin Seal) in the pilot/check-valve center block, page 66. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies HP-CB-PVPS (Pilot Valve Pin Seal) in the pilot/check-valve center block, page 66. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 66 ↗

View part & current price
PL-MTS-3/8X1/2B

High Pressure 3/8" NPT x 1/2" Tube Bronze w/ O-ring Straight

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The February 2012 Mk II manual identifies PL-MTS-3/8X1/2B (High Pressure 3/8" NPT x 1/2" Tube Bronze w/ O-ring Straight) in the membrane/boost-pump module, page 58. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity.

Manual, page 58 ↗

View part & current price
SO-HPP-ECCB

End Cap Center Block Seal

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Named in model manual

Confirm with Spectra before ordering. The February 2012 Mk II manual identifies SO-HPP-ECCB (End Cap Center Block Seal) in the cylinder assembly, page 67. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

The February 2012 Mk II manual identifies SO-HPP-ECCB (End Cap Center Block Seal) in the cylinder assembly, page 67. Match its labeled assembly position, connection and installed revision. The product page determines present package contents; repeated drawing locations do not set order quantity. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 67 ↗

View part & current price
HP-CB-CB20

Center Block 20% (W/O Inserts)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Confirmed current 20% arrangement: CB20 center block, two 7/8-inch rods and four PR10 rod-seal locations. Installed quantities are not supplied pack quantities. The Mk II 700 exterior also labels CB15; confirm pump ratio and actual revision with Spectra before applying this twin-rod reference. CB10, CB15 and CB20 are not interchangeable by model name.

Identification requirements & source

Confirmed current 20% arrangement: CB20 center block, two 7/8-inch rods and four PR10 rod-seal locations. Installed quantities are not supplied pack quantities. The Mk II 700 exterior also labels CB15; confirm pump ratio and actual revision with Spectra before applying this twin-rod reference. CB10, CB15 and CB20 are not interchangeable by model name.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 37 ↗

View part & current price
HP-CB-CV

Check Valve

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for HP-CB-CV in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for HP-CB-CV in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
HP-CB-CVR

Check Valve Retainer

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for HP-CB-CVR in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for HP-CB-CVR in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 45 ↗

View part & current price
HP-CB-CVS

Check Valve Seat

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for HP-CB-CVS in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for HP-CB-CVS in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
HP-CB-CVSW

Check Valve Spring Washer

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for HP-CB-CVSW in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for HP-CB-CVSW in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
HP-CB-INS

Center Block Insert

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for HP-CB-INS in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for HP-CB-INS in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
HP-CB-SPR

Check Valve Spring

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for HP-CB-SPR in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for HP-CB-SPR in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
HP‐CYL‐7/8R

Piston Rod (10%)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Confirmed current 20% arrangement: CB20 center block, two 7/8-inch rods and four PR10 rod-seal locations. Installed quantities are not supplied pack quantities. The Mk II 700 exterior also labels CB15; confirm pump ratio and actual revision with Spectra before applying this twin-rod reference. CB10, CB15 and CB20 are not interchangeable by model name.

Identification requirements & source

Confirmed current 20% arrangement: CB20 center block, two 7/8-inch rods and four PR10 rod-seal locations. Installed quantities are not supplied pack quantities. The Mk II 700 exterior also labels CB15; confirm pump ratio and actual revision with Spectra before applying this twin-rod reference. CB10, CB15 and CB20 are not interchangeable by model name.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 16 ↗

View part & current price
HP‐CYL‐PT20

Piston 20%

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. 20% piston/spool service reference for the confirmed current pump family. Delrin cylinder pistons have separate seal/bushing pieces; the 20PTA package and loose PT20 piston differ in scope. Old KIT-HP-10VS20 and VSP20 labels are not established aliases for the current 20VSA or one-inch top-end piston. Confirm actual revision and current contents with Spectra before duplicating hard parts or seals.

Identification requirements & source

20% piston/spool service reference for the confirmed current pump family. Delrin cylinder pistons have separate seal/bushing pieces; the 20PTA package and loose PT20 piston differ in scope. Old KIT-HP-10VS20 and VSP20 labels are not established aliases for the current 20VSA or one-inch top-end piston. Confirm actual revision and current contents with Spectra before duplicating hard parts or seals.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 72 ↗

View part & current price
HP‐CYL‐PTB20

Piston Bushing (20%)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for HP-CYL-PTB20 in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for HP-CYL-PTB20 in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 17 ↗

View part & current price
HP‐TB‐ARP

Annular Ring (Peek)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for HP-TB-ARP in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for HP-TB-ARP in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 19 ↗

View part & current price
HP‐TB‐VEB‐A

Valve End Block A 1" BORE, 20% CP

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current 20% top-end family uses A/B end blocks with one-inch bores, HP-TB-VSP1 spool pistons and SO-HPP-SP1 seals. The old Mk II reversing-valve page contains mixed VSP20 / PS20 labels. Confirm actual installed bore and revision with Spectra rather than assuming the old suffix establishes the current part. The larger 7%/10% A1/B1 family is excluded.

Identification requirements & source

Current 20% top-end family uses A/B end blocks with one-inch bores, HP-TB-VSP1 spool pistons and SO-HPP-SP1 seals. The old Mk II reversing-valve page contains mixed VSP20 / PS20 labels. Confirm actual installed bore and revision with Spectra rather than assuming the old suffix establishes the current part. The larger 7%/10% A1/B1 family is excluded.

Manual, page 61 ↗

View part & current price
HP‐TB‐VEB‐B

Valve End Block B 1" BORE, 20% CP

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current 20% top-end family uses A/B end blocks with one-inch bores, HP-TB-VSP1 spool pistons and SO-HPP-SP1 seals. The old Mk II reversing-valve page contains mixed VSP20 / PS20 labels. Confirm actual installed bore and revision with Spectra rather than assuming the old suffix establishes the current part. The larger 7%/10% A1/B1 family is excluded.

Identification requirements & source

Current 20% top-end family uses A/B end blocks with one-inch bores, HP-TB-VSP1 spool pistons and SO-HPP-SP1 seals. The old Mk II reversing-valve page contains mixed VSP20 / PS20 labels. Confirm actual installed bore and revision with Spectra rather than assuming the old suffix establishes the current part. The larger 7%/10% A1/B1 family is excluded.

Manual, page 61 ↗

View part & current price
KIT-HP-20PTA

20% Piston Assembly

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. 20% piston/spool service reference for the confirmed current pump family. Delrin cylinder pistons have separate seal/bushing pieces; the 20PTA package and loose PT20 piston differ in scope. Old KIT-HP-10VS20 and VSP20 labels are not established aliases for the current 20VSA or one-inch top-end piston. Confirm actual revision and current contents with Spectra before duplicating hard parts or seals.

Identification requirements & source

20% piston/spool service reference for the confirmed current pump family. Delrin cylinder pistons have separate seal/bushing pieces; the 20PTA package and loose PT20 piston differ in scope. Old KIT-HP-10VS20 and VSP20 labels are not established aliases for the current 20VSA or one-inch top-end piston. Confirm actual revision and current contents with Spectra before duplicating hard parts or seals.

Manual, page 72 ↗

View part & current price
KIT-HP-20VSA

Rev. Valve Spool Assembly (20%)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. 20% piston/spool service reference for the confirmed current pump family. Delrin cylinder pistons have separate seal/bushing pieces; the 20PTA package and loose PT20 piston differ in scope. Old KIT-HP-10VS20 and VSP20 labels are not established aliases for the current 20VSA or one-inch top-end piston. Confirm actual revision and current contents with Spectra before duplicating hard parts or seals.

Identification requirements & source

20% piston/spool service reference for the confirmed current pump family. Delrin cylinder pistons have separate seal/bushing pieces; the 20PTA package and loose PT20 piston differ in scope. Old KIT-HP-10VS20 and VSP20 labels are not established aliases for the current 20VSA or one-inch top-end piston. Confirm actual revision and current contents with Spectra before duplicating hard parts or seals.

Manual, page 20 ↗

View part & current price
SO-HPP-CVP1

Check Valve Port (Viton)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for SO-HPP-CVP1 in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for SO-HPP-CVP1 in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 16 ↗

View part & current price
HP‐CYL‐PTS20

Piston Seal (20%)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for HP-CYL-PTS20 in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for HP-CYL-PTS20 in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 17 ↗

View part & current price
SO-HPP-AR1

Annular Ring O-Ring (Viton)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for SO-HPP-AR1 in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for SO-HPP-AR1 in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 19 ↗

View part & current price
SO-HPP-CVS

Check Valve Seat Seal

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for SO-HPP-CVS in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for SO-HPP-CVS in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
SO-HPP-PLP

Pilot Ports Seal

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for SO-HPP-PLP in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for SO-HPP-PLP in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 16 ↗

View part & current price
SO-HPP-PR10

Piston Rod Seal

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Confirmed current 20% arrangement: CB20 center block, two 7/8-inch rods and four PR10 rod-seal locations. Installed quantities are not supplied pack quantities. The Mk II 700 exterior also labels CB15; confirm pump ratio and actual revision with Spectra before applying this twin-rod reference. CB10, CB15 and CB20 are not interchangeable by model name.

Identification requirements & source

Confirmed current 20% arrangement: CB20 center block, two 7/8-inch rods and four PR10 rod-seal locations. Installed quantities are not supplied pack quantities. The Mk II 700 exterior also labels CB15; confirm pump ratio and actual revision with Spectra before applying this twin-rod reference. CB10, CB15 and CB20 are not interchangeable by model name.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 40 ↗

View part & current price
SO-HPP-PS

Pin Seals

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for SO-HPP-PS in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for SO-HPP-PS in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
SO-HPP-PT20

20% Piston O-Ring

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. 20% piston/spool service reference for the confirmed current pump family. Delrin cylinder pistons have separate seal/bushing pieces; the 20PTA package and loose PT20 piston differ in scope. Old KIT-HP-10VS20 and VSP20 labels are not established aliases for the current 20VSA or one-inch top-end piston. Confirm actual revision and current contents with Spectra before duplicating hard parts or seals.

Identification requirements & source

20% piston/spool service reference for the confirmed current pump family. Delrin cylinder pistons have separate seal/bushing pieces; the 20PTA package and loose PT20 piston differ in scope. Old KIT-HP-10VS20 and VSP20 labels are not established aliases for the current 20VSA or one-inch top-end piston. Confirm actual revision and current contents with Spectra before duplicating hard parts or seals.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 72 ↗

View part & current price
SO-HPP-PV

Pilot Valve Seal

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for SO-HPP-PV in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for SO-HPP-PV in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
SO-HPP-RV

Relief Valve Seal

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for SO-HPP-RV in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for SO-HPP-RV in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 19 ↗

View part & current price
SO-HPP-SP1

Spool Piston O-Ring 1"

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current 20% top-end family uses A/B end blocks with one-inch bores, HP-TB-VSP1 spool pistons and SO-HPP-SP1 seals. The old Mk II reversing-valve page contains mixed VSP20 / PS20 labels. Confirm actual installed bore and revision with Spectra rather than assuming the old suffix establishes the current part. The larger 7%/10% A1/B1 family is excluded.

Identification requirements & source

Current 20% top-end family uses A/B end blocks with one-inch bores, HP-TB-VSP1 spool pistons and SO-HPP-SP1 seals. The old Mk II reversing-valve page contains mixed VSP20 / PS20 labels. Confirm actual installed bore and revision with Spectra rather than assuming the old suffix establishes the current part. The larger 7%/10% A1/B1 family is excluded.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 20 ↗

View part & current price
SO-HPP-VB

Valve Bore Seal

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for SO-HPP-VB in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for SO-HPP-VB in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 19 ↗

View part & current price
SO-HPP-VP

Valve Port Seal

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Clark Pump rebuild reference

Confirm with Spectra before ordering. Current Clark Pump rebuild identification for SO-HPP-VP in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Identification requirements & source

Current Clark Pump rebuild identification for SO-HPP-VP in a confirmed 20% pump. Match the exact seal location or hardware callout, installed ratio and revision. The older Mk II drawing has mixed ratio labels; confirm any 15% arrangement with Spectra before selecting these 20% internal references. This reference is limited to a confirmed 20% installed arrangement; confirm any historical 15% pump with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 16 ↗

View part & current price
EL-MPC-PCBDPA40

MPC-5000 circuit board, A40

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Current A40 MPC-5000 board route for an identified older MPC-5000 installation. B-series/A31 require board plus SP4; A34/A35 can instead retain their board with the required daughter interface. Confirm wiring/output and system programming with Spectra. This standalone board is not a complete MPC-3000 conversion or a Connect touchscreen.

Identification requirements & source

Current A40 MPC-5000 board route for an identified older MPC-5000 installation. B-series/A31 require board plus SP4; A34/A35 can instead retain their board with the required daughter interface. Confirm wiring/output and system programming with Spectra. This standalone board is not a complete MPC-3000 conversion or a Connect touchscreen.

Existing fitment requirements

  • Conditional board replacement only. Identify the installed controller and follow the Controller & Probe Replacement section on this page; review wiring and programming requirements before selecting hardware.

Manufacturer / research reference ↗

View part & current price
EL-MPC-RMCD

MPC LCD control display

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. MPC LCD remote display reference named in the Mk II manual. Match the installed MPC generation, Spectra cable and connector. The manual installation text specifies 75 feet but its parts list labels CBL50; confirm actual cable length with Spectra. Connect touchscreen displays and ordinary LAN cables are not replacements.

Identification requirements & source

MPC LCD remote display reference named in the Mk II manual. Match the installed MPC generation, Spectra cable and connector. The manual installation text specifies 75 feet but its parts list labels CBL50; confirm actual cable length with Spectra. Connect touchscreen displays and ordinary LAN cables are not replacements.

Existing fitment requirements

  • legacy MPC LCD display identified in this model manual. Retain MPC controls and matching display cable; not a Connect touchscreen, VFD display alias or three-button Remote panel. Historical fitment is supported; current factory supply is not established by this diagram.

Manufacturer / research reference ↗

View part & current price
EL-MPC-SP4

SP4 salinity probe, 15-foot cable

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Current SP4 15-foot probe reference for confirmed eligible MPC-5000 chips. A34/A35 need a daughter board or A40 upgrade; A36/A37/A39/A40 support SP4. The Mk II SP3 is obsolete. Confirm connector, cable reach and calibration with Spectra; an unknown chip does not establish direct fit.

Identification requirements & source

Current SP4 15-foot probe reference for confirmed eligible MPC-5000 chips. A34/A35 need a daughter board or A40 upgrade; A36/A37/A39/A40 support SP4. The Mk II SP3 is obsolete. Confirm connector, cable reach and calibration with Spectra; an unknown chip does not establish direct fit.

Existing fitment requirements

  • Identify the installed controller and follow the Controller & Probe Replacement section on this page. Match cable reach and connections; this configuration listing alone is not an unconditional replacement recommendation.

Manufacturer / research reference ↗

View part & current price
PL-SLN-1/4O12SP

1/4 2-Way Solenoid 12V Spar W/O Vbd

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Freshwater-flush valve reference, separate from product diversion. Mk II drawings label O12VB for the retained legacy body; ECI/Alcon coil conversion, Spartan Newport coil without body and with-body assembly have different scopes. Confirm actual body, adapter, connector and measured controller output with Spectra; a 24V main motor does not establish a 24V flush coil.

Identification requirements & source

Freshwater-flush valve reference, separate from product diversion. Mk II drawings label O12VB for the retained legacy body; ECI/Alcon coil conversion, Spartan Newport coil without body and with-body assembly have different scopes. Confirm actual body, adapter, connector and measured controller output with Spectra; a 24V main motor does not establish a 24V flush coil.

Manual, page 1 ↗

View part & current price
PL-SLN-1/4O12SV

12V freshwater-flush solenoid with valve body

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Freshwater-flush valve reference, separate from product diversion. Mk II drawings label O12VB for the retained legacy body; ECI/Alcon coil conversion, Spartan Newport coil without body and with-body assembly have different scopes. Confirm actual body, adapter, connector and measured controller output with Spectra; a 24V main motor does not establish a 24V flush coil.

Identification requirements & source

Freshwater-flush valve reference, separate from product diversion. Mk II drawings label O12VB for the retained legacy body; ECI/Alcon coil conversion, Spartan Newport coil without body and with-body assembly have different scopes. Confirm actual body, adapter, connector and measured controller output with Spectra; a 24V main motor does not establish a 24V flush coil.

Manual, page 1 ↗

View part & current price
FT-FHW-3PCS

3-Pcs Std 10" Filter Housing Wrench

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. The Mk II main prefilters and separate carbon flush unit use clear three-piece FT-FTH-10L3PCS housings. The manufacturer matrix pairs this family with SO-FHS-3PCS10 seals and FT-FHW-3PCS wrench. Identify the actual ring/bowl; a black 10H or Big Blue housing uses different service hardware.

Identification requirements & source

The Mk II main prefilters and separate carbon flush unit use clear three-piece FT-FTH-10L3PCS housings. The manufacturer matrix pairs this family with SO-FHS-3PCS10 seals and FT-FHW-3PCS wrench. Identify the actual ring/bowl; a black 10H or Big Blue housing uses different service hardware.

Manual, page 1 ↗

View part & current price
SO-FHS-3PCS10

3-Piece Filter Housing 0-Ring

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. The Mk II main prefilters and separate carbon flush unit use clear three-piece FT-FTH-10L3PCS housings. The manufacturer matrix pairs this family with SO-FHS-3PCS10 seals and FT-FHW-3PCS wrench. Identify the actual ring/bowl; a black 10H or Big Blue housing uses different service hardware.

Identification requirements & source

The Mk II main prefilters and separate carbon flush unit use clear three-piece FT-FTH-10L3PCS housings. The manufacturer matrix pairs this family with SO-FHS-3PCS10 seals and FT-FHW-3PCS wrench. Identify the actual ring/bowl; a black 10H or Big Blue housing uses different service hardware.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 1 ↗

View part & current price
KIT-NP-MK2-HCFM

Np Mk-Ii High Cap 10" Bb Flt Kit

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Manufacturer commercial dual-intake filter upgrade reference, separate from replacing the original small cartridges. Confirm the actual Mk II module, installation space, mounting, plumbing, fittings and current kit contents with Spectra; the code alone does not establish everything needed for this retrofit.

Identification requirements & source

Manufacturer commercial dual-intake filter upgrade reference, separate from replacing the original small cartridges. Confirm the actual Mk II module, installation space, mounting, plumbing, fittings and current kit contents with Spectra; the code alone does not establish everything needed for this retrofit.

Manufacturer / research reference ↗

View part & current price
KIT-OFFSH1

Offshore Kit For 20%

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Current manufacturer reference

Confirm with Spectra before ordering. 20% offshore kit includes service tools, seals and cleaning supplies; manufacturer says it does not include piston rods or cylinder pistons. The manual generic KIT-OFFSH label is not the present 7%/10% listing. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Identification requirements & source

20% offshore kit includes service tools, seals and cleaning supplies; manufacturer says it does not include piston rods or cylinder pistons. The manual generic KIT-OFFSH label is not the present 7%/10% listing. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Existing fitment requirements

  • Installed 20% Clark Pump; select full rebuild or offshore kit according to the service required.
  • Corrected against the newer Clark guide: installed 20% Newport 700/1000 pump requires KIT-OFFSH1.

Manufacturer / research reference ↗

View part & current price
PL-SLN-1/4D12SP

1/4 Diversion Valve 12V Spartan

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Product-water diversion valve/manifold reference, separate from intake and freshwater flush. The Mk II drawing names a 12V D12M valve; later Spartan and Burkert conversion routes differ in body, output and fittings. Confirm actual valve, MPC output and conversion contents with Spectra; 24V main-feed power does not establish a 24V diversion coil.

Identification requirements & source

Product-water diversion valve/manifold reference, separate from intake and freshwater flush. The Mk II drawing names a 12V D12M valve; later Spartan and Burkert conversion routes differ in body, output and fittings. Confirm actual valve, MPC output and conversion contents with Spectra; 24V main-feed power does not establish a 24V diversion coil.

Manual, page 1 ↗

View part & current price
SUB-NP-DVMSP

Diversion Valve Manifold Sparton

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Product-water diversion valve/manifold reference, separate from intake and freshwater flush. The Mk II drawing names a 12V D12M valve; later Spartan and Burkert conversion routes differ in body, output and fittings. Confirm actual valve, MPC output and conversion contents with Spectra; 24V main-feed power does not establish a 24V diversion coil.

Identification requirements & source

Product-water diversion valve/manifold reference, separate from intake and freshwater flush. The Mk II drawing names a 12V D12M valve; later Spartan and Burkert conversion routes differ in body, output and fittings. Confirm actual valve, MPC output and conversion contents with Spectra; 24V main-feed power does not establish a 24V diversion coil.

Manual, page 1 ↗

View part & current price
SUB-NP-MK2-INEZ

Newport Intake Manifold Eci Z-Ion

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Current body selector: six fitting holes and approximately 1-inch solenoid opening. The Mk II drawing names INT. Count actual holes and identify valve/adapter before using a later body. Confirm mounting and fittings with Spectra after changes; this intake manifold is separate from product-water diversion. A Z-suffix body is not proof that a Z-Ion generator is installed.

Identification requirements & source

Current body selector: six fitting holes and approximately 1-inch solenoid opening. The Mk II drawing names INT. Count actual holes and identify valve/adapter before using a later body. Confirm mounting and fittings with Spectra after changes; this intake manifold is separate from product-water diversion. A Z-suffix body is not proof that a Z-Ion generator is installed.

Existing fitment requirements

  • Six-hole manifold with legacy 1-inch ECI/Alcon solenoid opening; different from INTZ. Spartan conversion requires an adapter. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid.

Manual, page 1 ↗

View part & current price
SUB-NP-MK2-INT

Newport Manifold Eci Pre Z-Ion

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Current body selector: five fitting holes and approximately 1-inch solenoid opening. The Mk II drawing names INT. Count actual holes and identify valve/adapter before using a later body. Confirm mounting and fittings with Spectra after changes; this intake manifold is separate from product-water diversion. A Z-suffix body is not proof that a Z-Ion generator is installed.

Identification requirements & source

Current body selector: five fitting holes and approximately 1-inch solenoid opening. The Mk II drawing names INT. Count actual holes and identify valve/adapter before using a later body. Confirm mounting and fittings with Spectra after changes; this intake manifold is separate from product-water diversion. A Z-suffix body is not proof that a Z-Ion generator is installed.

Existing fitment requirements

  • Five-hole manifold and legacy 1-inch ECI/Alcon solenoid opening. Current Spartan solenoid requires the appropriate adapter. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid.

Manual, page 1 ↗

View part & current price
SUB-NP-MK2-INTZ

Newport Mk-Ii Intake Manifold Z-Ion

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Current body selector: six fitting holes and approximately 3/4-inch Spartan opening. The Mk II drawing names INT. Count actual holes and identify valve/adapter before using a later body. Confirm mounting and fittings with Spectra after changes; this intake manifold is separate from product-water diversion. A Z-suffix body is not proof that a Z-Ion generator is installed.

Identification requirements & source

Current body selector: six fitting holes and approximately 3/4-inch Spartan opening. The Mk II drawing names INT. Count actual holes and identify valve/adapter before using a later body. Confirm mounting and fittings with Spectra after changes; this intake manifold is separate from product-water diversion. A Z-suffix body is not proof that a Z-Ion generator is installed.

Existing fitment requirements

  • Six external fitting holes and approximately 3/4-inch top threaded solenoid port. Identify installed manifold, not model year alone. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid.

Manual, page 1 ↗

View part & current price
EL-FP-BPLDC824IM

Laing Booster Pump Impeller

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Manufacturer identifies this impeller for the EL-FP-BPLDC824 Laing boost pump. Identify the actual booster body and service revision with Spectra before selecting it; this is not an impeller for the magnetic-drive vane head and does not replace an entire boost module or electrical fault.

Identification requirements & source

Manufacturer identifies this impeller for the EL-FP-BPLDC824 Laing boost pump. Identify the actual booster body and service revision with Spectra before selecting it; this is not an impeller for the magnetic-drive vane head and does not replace an entire boost module or electrical fault.

Manufacturer / research reference ↗

View part & current price
KIT-HP-S&OH

Seals & O-Rings Kit 20%

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Current manufacturer reference

Confirm with Spectra before ordering. 20% seal/O-ring kit; it is distinct from the 7%/10% kit and the distributor hard-parts rebuild kit. The manufacturer page currently names KIT-S&OH, while this catalog uses KIT-HP-S&OH. Confirm the code and present contents before assuming suffix equivalence. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Identification requirements & source

20% seal/O-ring kit; it is distinct from the 7%/10% kit and the distributor hard-parts rebuild kit. The manufacturer page currently names KIT-S&OH, while this catalog uses KIT-HP-S&OH. Confirm the code and present contents before assuming suffix equivalence. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Existing fitment requirements

  • Select the installed 20% Clark Pump. The factory bulletin documents 20%; it does not establish 15% compatibility.

Manufacturer / research reference ↗

View part & current price
KIT-HP-20UD

20% Clark Pump Upgrade Kit Dist.

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Current manufacturer reference

Confirm with Spectra before ordering. 20% distributor rebuild kit. Manufacturer contents exclude spacer rings and top-end spool pistons; tools and instructions are not supplied. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Identification requirements & source

20% distributor rebuild kit. Manufacturer contents exclude spacer rings and top-end spool pistons; tools and instructions are not supplied. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Existing fitment requirements

  • Installed 20% Clark Pump; select full rebuild or offshore kit according to the service required. Requires the installed 20% Clark Pump and matching revision. Verify the pump identification after any retrofit; system name alone is insufficient. Requires the installed 20% Clark Pump and matching revision. Verify the pump identification after any retrofit; system name alone is insufficient.

Manufacturer / research reference ↗

View part & current price
KIT-MNF-BURDV12

Burkert diversion-valve conversion kit

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Product-water diversion valve/manifold reference, separate from intake and freshwater flush. The Mk II drawing names a 12V D12M valve; later Spartan and Burkert conversion routes differ in body, output and fittings. Confirm actual valve, MPC output and conversion contents with Spectra; 24V main-feed power does not establish a 24V diversion coil.

Identification requirements & source

Product-water diversion valve/manifold reference, separate from intake and freshwater flush. The Mk II drawing names a 12V D12M valve; later Spartan and Burkert conversion routes differ in body, output and fittings. Confirm actual valve, MPC output and conversion contents with Spectra; 24V main-feed power does not establish a 24V diversion coil.

Manual, page 1 ↗

View part & current price
KIT-MPC-5KUPG12

Mpc-5000 Upgrade Kit 12V

24V DC / 110V AC / 220V AC layout references · 12V DC controls — identify separately · Current manufacturer reference

Confirm with Spectra before ordering. Conditional MPC-3000 to MPC-5000 conversion only for an actually identified earlier or changed control box; the factory Mk II manual already specifies MPC-5000. Select by confirmed controls supply at the board, including any DC/DC converter, not the main DC24 motor or AC input. Kit includes A40, SP4, Rotoflo and fittings; 24V kit also includes a 12V flush solenoid. Confirm Newport wiring re-termination, output circuits, speed-control interface and programming with Spectra. Retained display and motor conversions are separate scopes.

Identification requirements & source

Conditional MPC-3000 to MPC-5000 conversion only for an actually identified earlier or changed control box; the factory Mk II manual already specifies MPC-5000. Select by confirmed controls supply at the board, including any DC/DC converter, not the main DC24 motor or AC input. Kit includes A40, SP4, Rotoflo and fittings; 24V kit also includes a 12V flush solenoid. Confirm Newport wiring re-termination, output circuits, speed-control interface and programming with Spectra. Retained display and motor conversions are separate scopes.

Manufacturer / research reference ↗

View part & current price
KIT-MPC-5KUPG24

Mpc-5000 Upgrade Kit 24V

24V DC / 110V AC / 220V AC layout references · 24V DC controls — identify separately · Current manufacturer reference

Confirm with Spectra before ordering. Conditional MPC-3000 to MPC-5000 conversion only for an actually identified earlier or changed control box; the factory Mk II manual already specifies MPC-5000. Select by confirmed controls supply at the board, including any DC/DC converter, not the main DC24 motor or AC input. Kit includes A40, SP4, Rotoflo and fittings; 24V kit also includes a 12V flush solenoid. Confirm Newport wiring re-termination, output circuits, speed-control interface and programming with Spectra. Retained display and motor conversions are separate scopes.

Identification requirements & source

Conditional MPC-3000 to MPC-5000 conversion only for an actually identified earlier or changed control box; the factory Mk II manual already specifies MPC-5000. Select by confirmed controls supply at the board, including any DC/DC converter, not the main DC24 motor or AC input. Kit includes A40, SP4, Rotoflo and fittings; 24V kit also includes a 12V flush solenoid. Confirm Newport wiring re-termination, output circuits, speed-control interface and programming with Spectra. Retained display and motor conversions are separate scopes.

Manufacturer / research reference ↗

View part & current price
KIT-SLN-ECISPO1

Eci To Sparton 1-W Valve Kit 12V

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Freshwater-flush valve reference, separate from product diversion. Mk II drawings label O12VB for the retained legacy body; ECI/Alcon coil conversion, Spartan Newport coil without body and with-body assembly have different scopes. Confirm actual body, adapter, connector and measured controller output with Spectra; a 24V main motor does not establish a 24V flush coil.

Identification requirements & source

Freshwater-flush valve reference, separate from product diversion. Mk II drawings label O12VB for the retained legacy body; ECI/Alcon coil conversion, Spartan Newport coil without body and with-body assembly have different scopes. Confirm actual body, adapter, connector and measured controller output with Spectra; a 24V main motor does not establish a 24V flush coil.

Manual, page 1 ↗

View part & current price
Additional candidates requiring confirmation

Confirm these specific links with Spectra before ordering. The source does not prove direct interchangeability, exact current revision or complete conversion contents.

EL-MPC-SP4N

SP4N probe, 3-foot cable — confirm connection

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Short-cable SP4N catalog candidate. Current chip guidance explicitly names SP4, not every N-suffix connector/length revision. Confirm the actual probe socket, three-foot reach and required interface with Spectra. This is not an automatic interchangeable alias for the 15-foot SP4.

Identification requirements & source

Short-cable SP4N catalog candidate. Current chip guidance explicitly names SP4, not every N-suffix connector/length revision. Confirm the actual probe socket, three-foot reach and required interface with Spectra. This is not an automatic interchangeable alias for the 15-foot SP4.

Manufacturer / research reference ↗

View part & current price
EL-MTR-PWMWOHS

12/24V PWM Controller without Heat Sink

24V DC feed-power candidate · Installed-hardware review

Confirm with Spectra before ordering. The Mk II 700/1000 DC drawing specifies EL-MTR-PWMA24 for its one-HP motor; this catalog listing has a different suffix/scope. Confirm high-current compatibility, heat sink, terminals and Spectra programming with the actual motor/controller before ordering. A generic 12/24V PWM name does not prove it is the required larger-motor controller.

Identification requirements & source

The Mk II 700/1000 DC drawing specifies EL-MTR-PWMA24 for its one-HP motor; this catalog listing has a different suffix/scope. Confirm high-current compatibility, heat sink, terminals and Spectra programming with the actual motor/controller before ordering. A generic 12/24V PWM name does not prove it is the required larger-motor controller.

Manual, page 61 ↗

View part & current price
FT-FHW-10H

H. P. Filter Housing Wrench

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Black high-pressure 10H housing family: FT-FTH-10H, SO-FHS-10H seal and FT-FHW-10H or 10HSS wrench. These are changed-housing references; the factory Mk II diagrams show clear three-piece bowls. Confirm actual bowl, ring and pressure rating with Spectra; the black-housing seal is not the three-piece seal.

Identification requirements & source

Black high-pressure 10H housing family: FT-FTH-10H, SO-FHS-10H seal and FT-FHW-10H or 10HSS wrench. These are changed-housing references; the factory Mk II diagrams show clear three-piece bowls. Confirm actual bowl, ring and pressure rating with Spectra; the black-housing seal is not the three-piece seal.

Manual, page 1 ↗

View part & current price
FT-FHW-10HSS

High Pressure Filter Housomg Wrench Ss.

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Black high-pressure 10H housing family: FT-FTH-10H, SO-FHS-10H seal and FT-FHW-10H or 10HSS wrench. These are changed-housing references; the factory Mk II diagrams show clear three-piece bowls. Confirm actual bowl, ring and pressure rating with Spectra; the black-housing seal is not the three-piece seal.

Identification requirements & source

Black high-pressure 10H housing family: FT-FTH-10H, SO-FHS-10H seal and FT-FHW-10H or 10HSS wrench. These are changed-housing references; the factory Mk II diagrams show clear three-piece bowls. Confirm actual bowl, ring and pressure rating with Spectra; the black-housing seal is not the three-piece seal.

Manual, page 1 ↗

View part & current price
FT-FTC-20BB

20 Micron Big Blue Filter Cartridge (10")

24V DC / 110V AC / 220V AC layout references · commercial prefilter arrangement · Installed-hardware review

Confirm with Spectra before ordering. 10-inch nominal Big Blue cartridge candidate for an actually installed commercial dual-filter upgrade. It is a different diameter family from the standard 10 × 2.5-inch elements. Confirm measured diameter, end style and actual housing/kit with Spectra. The matrix housing length is not the cartridge length; do not substitute a 20-inch BB element.

Identification requirements & source

10-inch nominal Big Blue cartridge candidate for an actually installed commercial dual-filter upgrade. It is a different diameter family from the standard 10 × 2.5-inch elements. Confirm measured diameter, end style and actual housing/kit with Spectra. The matrix housing length is not the cartridge length; do not substitute a 20-inch BB element.

Manufacturer / research reference ↗

View part & current price
FT-FTC-50

50 Micron Filter Element

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. A dated June 2004 PF-4 bulletin appended to the 2012 manual describes an additional 50-micron stage before the booster. The main Mk II plumbing and labeled intake drawing do not identify that extra housing. Confirm whether it is actually fitted and required on this installation with Spectra. Exact cartridge length, diameter and end style are not independently established here; do not add the older stage by model name alone.

Identification requirements & source

A dated June 2004 PF-4 bulletin appended to the 2012 manual describes an additional 50-micron stage before the booster. The main Mk II plumbing and labeled intake drawing do not identify that extra housing. Confirm whether it is actually fitted and required on this installation with Spectra. Exact cartridge length, diameter and end style are not independently established here; do not add the older stage by model name alone.

Manual, page 50 ↗

View part & current price
FT-FTC-5BB

5 Micron Big Blue Filter Cartridge (10")

24V DC / 110V AC / 220V AC layout references · commercial prefilter arrangement · Installed-hardware review

Confirm with Spectra before ordering. 10-inch nominal Big Blue cartridge candidate for an actually installed commercial dual-filter upgrade. It is a different diameter family from the standard 10 × 2.5-inch elements. Confirm measured diameter, end style and actual housing/kit with Spectra. The matrix housing length is not the cartridge length; do not substitute a 20-inch BB element.

Identification requirements & source

10-inch nominal Big Blue cartridge candidate for an actually installed commercial dual-filter upgrade. It is a different diameter family from the standard 10 × 2.5-inch elements. Confirm measured diameter, end style and actual housing/kit with Spectra. The matrix housing length is not the cartridge length; do not substitute a 20-inch BB element.

Manufacturer / research reference ↗

View part & current price
FT-FTH-10H

High Pressure Filter Housing (Blk)

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Black high-pressure 10H housing family: FT-FTH-10H, SO-FHS-10H seal and FT-FHW-10H or 10HSS wrench. These are changed-housing references; the factory Mk II diagrams show clear three-piece bowls. Confirm actual bowl, ring and pressure rating with Spectra; the black-housing seal is not the three-piece seal.

Identification requirements & source

Black high-pressure 10H housing family: FT-FTH-10H, SO-FHS-10H seal and FT-FHW-10H or 10HSS wrench. These are changed-housing references; the factory Mk II diagrams show clear three-piece bowls. Confirm actual bowl, ring and pressure rating with Spectra; the black-housing seal is not the three-piece seal.

Manual, page 1 ↗

View part & current price
FT-STN-6S

6" Strainer Screen (Large)

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 6" Strainer Screen (Large) is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Identification requirements & source

6" Strainer Screen (Large) is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 6 ↗

View part & current price
KIT-MB-40F

Long membrane kit, 2.5 × 40 inches

24V DC / 110V AC / 220V AC layout references · confirmed 2.5 × 40-inch element; system count requires confirmation · Installed-hardware review

Confirm with Spectra before ordering. One kit supplies one 2.5 × 40-inch seawater element and replacement seals. The shared Mk II diagrams show both two- and three-vessel assemblies without an explicit model-specific element-dimension/count table. Later Newport 700 layouts use 2 long elements; confirm actual Mk II element size, count and end caps with Spectra before treating that as this installation. No full-system quantity is selected automatically.

Identification requirements & source

One kit supplies one 2.5 × 40-inch seawater element and replacement seals. The shared Mk II diagrams show both two- and three-vessel assemblies without an explicit model-specific element-dimension/count table. Later Newport 700 layouts use 2 long elements; confirm actual Mk II element size, count and end caps with Spectra before treating that as this installation. No full-system quantity is selected automatically.

Manufacturer / research reference ↗

View part & current price
EL-MTR-PWMA

Spectra Pwm Assembly 12/24V

24V DC feed-power candidate · Installed-hardware review

Confirm with Spectra before ordering. The Mk II 700/1000 DC drawing specifies EL-MTR-PWMA24 for its one-HP motor; this catalog listing has a different suffix/scope. Confirm high-current compatibility, heat sink, terminals and Spectra programming with the actual motor/controller before ordering. A generic 12/24V PWM name does not prove it is the required larger-motor controller.

Identification requirements & source

The Mk II 700/1000 DC drawing specifies EL-MTR-PWMA24 for its one-HP motor; this catalog listing has a different suffix/scope. Confirm high-current compatibility, heat sink, terminals and Spectra programming with the actual motor/controller before ordering. A generic 12/24V PWM name does not prove it is the required larger-motor controller.

Manual, page 61 ↗

View part & current price
HP-CB-CB15

Center Block 15% (W/O Inserts)

24V DC / 110V AC / 220V AC layout references · confirmed 15% Clark Pump · Installed-hardware review

Confirm with Spectra before ordering. Historical Newport 700 exterior drawing names CB15, while the same manual shipping list and module pictures name a 20% pump. Current 700/1000 service kits are described for 20%. This conditional 15% block link is only for an actually identified 15% pump; give Spectra the label and serial number to confirm original block, inserts and approved replacement. Do not assume CB15 and CB20 or their rebuild kits interchange.

Identification requirements & source

Historical Newport 700 exterior drawing names CB15, while the same manual shipping list and module pictures name a 20% pump. Current 700/1000 service kits are described for 20%. This conditional 15% block link is only for an actually identified 15% pump; give Spectra the label and serial number to confirm original block, inserts and approved replacement. Do not assume CB15 and CB20 or their rebuild kits interchange.

Manual, page 64 ↗

View part & current price
KIT-MTR-LSBK

Leeson Brush Kit

24V DC feed-power candidate · Installed-hardware review

Confirm with Spectra before ordering. Leeson DC motor service candidate for a positively identified motor, not a universal Newport motor part. Confirm the installed motor manufacturer/model and the exact brush/spring set with Spectra. A current 56C frame or 24V rating alone does not establish the same brush geometry; Bodine and AC motor parts are different.

Identification requirements & source

Leeson DC motor service candidate for a positively identified motor, not a universal Newport motor part. Confirm the installed motor manufacturer/model and the exact brush/spring set with Spectra. A current 56C frame or 24V rating alone does not establish the same brush geometry; Bodine and AC motor parts are different.

Manual, page 61 ↗

View part & current price
KIT-PV-25EP1

2.5" Pressure Vessel End Plug Replacement Kit

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Membrane vessel retaining hardware is separate from the replacement element. Mk II diagrams label the older FT-PV-EP end plug and FT-PV-ER ring; optional Z-Brane electrodes use dedicated end-plug fittings. Confirm actual plug, retaining ring and electrode revision with Spectra before using the later KIT-PV-25EP1 route. A mounting-bracket end is another part.

Identification requirements & source

Membrane vessel retaining hardware is separate from the replacement element. Mk II diagrams label the older FT-PV-EP end plug and FT-PV-ER ring; optional Z-Brane electrodes use dedicated end-plug fittings. Confirm actual plug, retaining ring and electrode revision with Spectra before using the later KIT-PV-25EP1 route. A mounting-bracket end is another part.

Manual, page 30 ↗

View part & current price
PL-MFF-1/4X1/4

1/4"Npt X 1/4" Fpt Elbow Fitting Nyl

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 1/4"Npt X 1/4" Fpt Elbow Fitting Nyl is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Identification requirements & source

1/4"Npt X 1/4" Fpt Elbow Fitting Nyl is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 6 ↗

View part & current price
PL-NLT-5/8

5/8" Nylon Tube Low Pressure (Per Foot)

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 5/8" Nylon Tube Low Pressure (Per Foot) is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Identification requirements & source

5/8" Nylon Tube Low Pressure (Per Foot) is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Length is not established; measure the run and retain the specified hose/tube duty.

Manual, page 6 ↗

View part & current price
PL-VLV-3/4PVC

3/4"Npt X 3/4"Fpt 1-Way Pvc Valve

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 3/4"Npt X 3/4"Fpt 1-Way Pvc Valve is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Identification requirements & source

3/4"Npt X 3/4"Fpt 1-Way Pvc Valve is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Existing fitment requirements

  • Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 6 ↗

View part & current price
SUB-NP-MK2-ILHA

Np Mk-Ii 700/1K Inlet Hose Assembly

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Np Mk-Ii 700/1K Inlet Hose Assembly is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Identification requirements & source

Np Mk-Ii 700/1K Inlet Hose Assembly is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Existing fitment requirements

  • Manufacturer-approved retrofit for Newport 700/1000 Mk II with the original rigid feed-to-Clark tubing. Especially identifies systems shipped before October 2009. Excludes Mk I; record an installed retrofit before selecting later service parts.

Manual, page 6 ↗

View part & current price
KIT-BCK-B

Cruise Kit B

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. The Mk II spares list calls its two-sediment-filter package Basic Cruise Kit B but prints KIT-BCK-C; current store kit names differ. Confirm present kit contents and quantities with Spectra against the actual 20- and 5-micron cartridges and SC-1 supplies. Kit name/letter alone does not resolve this historical mismatch; carry-on quantities are not installed filter quantities.

Identification requirements & source

The Mk II spares list calls its two-sediment-filter package Basic Cruise Kit B but prints KIT-BCK-C; current store kit names differ. Confirm present kit contents and quantities with Spectra against the actual 20- and 5-micron cartridges and SC-1 supplies. Kit name/letter alone does not resolve this historical mismatch; carry-on quantities are not installed filter quantities.

Manual, page 6 ↗

View part & current price
KIT-BCK-C

Cruise Kit C

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. The Mk II spares list calls its two-sediment-filter package Basic Cruise Kit B but prints KIT-BCK-C; current store kit names differ. Confirm present kit contents and quantities with Spectra against the actual 20- and 5-micron cartridges and SC-1 supplies. Kit name/letter alone does not resolve this historical mismatch; carry-on quantities are not installed filter quantities.

Identification requirements & source

The Mk II spares list calls its two-sediment-filter package Basic Cruise Kit B but prints KIT-BCK-C; current store kit names differ. Confirm present kit contents and quantities with Spectra against the actual 20- and 5-micron cartridges and SC-1 supplies. Kit name/letter alone does not resolve this historical mismatch; carry-on quantities are not installed filter quantities.

Manual, page 6 ↗

View part & current price
KIT-HP-20R

20% Clark Pump Reman. (Core $2,200)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Installed-hardware review

Confirm with Spectra before ordering. Remanufactured 20% pump route; confirm actual exchange/core terms, pump revision and supplied fittings. It is separate from loose rebuild parts. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Identification requirements & source

Remanufactured 20% pump route; confirm actual exchange/core terms, pump revision and supplied fittings. It is separate from loose rebuild parts. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Existing fitment requirements

  • Factory service for an installed 20% Clark Pump; confirm current RMA, freight and exchange deposit/return terms.

Manual, page 58 ↗

View part & current price
KIT-HP-20U

20% Clark Pump Upgrade (Org. Cust. Pmp)

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Installed-hardware review

Confirm with Spectra before ordering. Factory service/upgrade of a customer-owned 20% pump; confirm eligibility, handling and actual work scope. It is separate from an exchange assembly. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Identification requirements & source

Factory service/upgrade of a customer-owned 20% pump; confirm eligibility, handling and actual work scope. It is separate from an exchange assembly. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Existing fitment requirements

  • Factory service for an installed 20% Clark Pump; confirm current RMA, freight and repair arrangements.

Manual, page 58 ↗

View part & current price
KIT-HP20

High Press. Pump 20% For N.P. Assem

24V DC / 110V AC / 220V AC layout references · confirmed 20% Clark Pump · Installed-hardware review

Confirm with Spectra before ordering. Complete 20% Clark Pump assembly named in the Mk II module drawings. Confirm mounting, fittings and supplied contents; it is not just a center block or rebuild kit. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Identification requirements & source

Complete 20% Clark Pump assembly named in the Mk II module drawings. Confirm mounting, fittings and supplied contents; it is not just a center block or rebuild kit. Confirm installed ratio and revision with Spectra, particularly on a Newport 700 with the conflicting historical CB15 callout. Compare current contents before ordering overlapping loose items.

Manual, page 58 ↗

View part & current price
KIT-PMP-240MRF

240 Mag Pump- Remanufactured (C250)

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Current remanufactured 240 MAG package candidate, separate from the named bare PL-PMP-240MAG5 head. Confirm head revision, package components, coupling and current core/exchange terms with Spectra. This listing does not automatically include the Mk II motor, speed controller or booster.

Identification requirements & source

Current remanufactured 240 MAG package candidate, separate from the named bare PL-PMP-240MAG5 head. Confirm head revision, package components, coupling and current core/exchange terms with Spectra. This listing does not automatically include the Mk II motor, speed controller or booster.

Manual, page 6 ↗

View part & current price
EL-SWT-TSBHC

Toggle Switch Boot Seal

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Toggle Switch Boot Seal is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Identification requirements & source

Toggle Switch Boot Seal is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Existing fitment requirements

  • item in the identified generation and enclosure. Match switch poles/terminals, boot or enclosure dimensions, and instrument range/connection as applicable. A similar label on another control generation is not a substitution.

Manual, page 6 ↗

View part & current price
SO-FHS-10H

High Pressure Filter Housing O-ring

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Black high-pressure 10H housing family: FT-FTH-10H, SO-FHS-10H seal and FT-FHW-10H or 10HSS wrench. These are changed-housing references; the factory Mk II diagrams show clear three-piece bowls. Confirm actual bowl, ring and pressure rating with Spectra; the black-housing seal is not the three-piece seal.

Identification requirements & source

Black high-pressure 10H housing family: FT-FTH-10H, SO-FHS-10H seal and FT-FHW-10H or 10HSS wrench. These are changed-housing references; the factory Mk II diagrams show clear three-piece bowls. Confirm actual bowl, ring and pressure rating with Spectra; the black-housing seal is not the three-piece seal.

Manual, page 1 ↗

View part & current price
SO-STN-6SS

6" Strainer Seal (Big)

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 6" Strainer Seal (Big) is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Identification requirements & source

6" Strainer Seal (Big) is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 6 ↗

View part & current price
ZION-AUTO

Z-Ion For Auto System

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Z-Ion For Auto System is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Identification requirements & source

Z-Ion For Auto System is an installed-hardware candidate retained for the Mk II reference list. The model manual does not establish this exact present code as a complete direct replacement. Confirm the original assembly label, part location, connectors and required companion pieces with Spectra before ordering.

Existing fitment requirements

  • Optional Z-Ion control type for MPC, Connect and Remote Manual. Confirm installed generation, suitable accessory power and plumbing before installation.

Manual, page 6 ↗

View part & current price

KEEP THE ORIGINAL AND CURRENT REFERENCES TOGETHER

Manuals and manufacturer resources