Overview
Overview
PL-SLN-1/4D12M — 1/4" DIVERSION VALVE 12 V (MNF).
This component directs or switches water flow in the controlled valve assembly identified in the listing. Match the valve function, port arrangement and actuator voltage where applicable.
Specifications & Contents
Specifications & Contents
| Part number | PL-SLN-1/4D12M |
|---|---|
| Brand | Spectra Watermakers |
| Listed component | 1/4" DIVERSION VALVE 12 V (MNF) |
Fits My System
Fits My System
Match the exact configuration and installed hardware. A shared family name alone does not establish fit.
Select your configuration to see its requirements, or open the complete reference below.
All documented configurations and requirements
Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.
Documented configurations
- Bimini 300C · Connect · Match installed voltage and hardware
documented Connect sensor/diversion assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match the sensor range, connector and manifold position. Component voltage can differ from system input; use the documented control supply.
Documented configurations
- Catalina 340C · Connect · 12 VDC · Compact / short membranes · CT-340C-12S
- Catalina 340C · Connect · 12 VDC · Standard / long membranes · CT-340C-12
- Catalina 340C · Connect · 24 VDC · Compact / short membranes · CT-340C-24S
- Catalina 340C · Connect · 24 VDC · Standard / long membranes · CT-340C-24
- Catalina 340C · Connect · 48 VDC · Compact / short membranes · CT-340C-48S
- Catalina 340C · Connect · 48 VDC · Standard / long membranes · CT-340C-48
documented Connect sensor/diversion assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match the sensor range, connector and manifold position. Component voltage can differ from system input; use the documented control supply.
Documented configurations
- Newport 1000 Mk II · MPC 5000 · Match installed voltage and hardware
- Newport 700 Mk II · MPC 5000 · Match installed voltage and hardware
12V Burkert diversion valve in the specified Newport manifold; match its manual-override valve and connector. Component voltage is the control-circuit voltage, not system input voltage.
Parts diagram / guide, page 61 · Parts diagram / guide, page 1
Documented configurations
- Newport 1000 Mk II-Z · MPC 5000 · Match installed voltage and hardware
- Newport 700 Mk II-Z · MPC 5000 · Match installed voltage and hardware
12V Burkert diversion valve in the specified Newport manifold; match its manual-override valve and connector. Component voltage is the control-circuit voltage, not system input voltage.
Parts diagram / guide, page 85 · Parts diagram / guide, page 1
Documented configurations
- Newport 1000C · Connect · 110 VAC · Standard / long membranes · NP-1000C-110
- Newport 1000C · Connect · 220 VAC · Standard / long membranes · NP-1000C-220
- Newport 1000C · Connect · 24 VDC · Standard / long membranes · NP-1000C-24
- Newport 1000C · Connect · 48 VDC · Standard / long membranes · NP-1000C-48
- Newport 700C · Connect · 110 VAC · Standard / long membranes · NP-700C-110
- Newport 700C · Connect · 220 VAC · Standard / long membranes · NP-700C-220
- Newport 700C · Connect · 24 VDC · Standard / long membranes · NP-700C-24
- Newport 700C · Connect · 48 VDC · Standard / long membranes · NP-700C-48
documented Connect sensor/diversion assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match the sensor range, connector and manifold position. Component voltage can differ from system input; use the documented control supply.
Documented configurations
- Newport 400 Mk II · MPC 5000 · Match installed voltage and hardware
12V Burkert diversion valve in the specified Newport manifold; match its manual-override valve and connector. Component voltage is the control-circuit voltage, not system input voltage.
Parts diagram / guide, page 59 · Parts diagram / guide, page 1
Documented configurations
- Newport 400 Mk II-Z · MPC 5000 · Match installed voltage and hardware
12V Burkert diversion valve in the specified Newport manifold; match its manual-override valve and connector. Component voltage is the control-circuit voltage, not system input voltage.
Parts diagram / guide, page 80 · Parts diagram / guide, page 1
Documented configurations
- Newport 400C · Connect · 12 VDC · Compact / short membranes · NP-400C-12S
- Newport 400C · Connect · 12 VDC · Standard / long membranes · NP-400C-12
- Newport 400C · Connect · 24 VDC · Compact / short membranes · NP-400C-24S
- Newport 400C · Connect · 24 VDC · Standard / long membranes · NP-400C-24
- Newport 400C · Connect · 48 VDC · Compact / short membranes · NP-400C-48S
- Newport 400C · Connect · 48 VDC · Standard / long membranes · NP-400C-48
documented Connect sensor/diversion assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match the sensor range, connector and manifold position. Component voltage can differ from system input; use the documented control supply.
Documented configurations
- Ventura 150C · Connect · 12 VDC · Standard · VT-150C-12V
- Ventura 150C · Connect · 24 VDC · Standard · VT-150C-24V
- Ventura 200C · Connect · 12 VDC · Standard · VT-200C-12V
- Ventura 200C · Connect · 24 VDC · Standard · VT-200C-24V
The visible May 2025 manufacturer diagram explicitly labels D12M on the Burkert manifold PL-MNF-DVMBK1P. Ignore the stale D12SP text retained in the PDF extraction layer. Match the illustrated manifold, manual override and 12V control circuit; no Spartan-body substitution.
Parts diagram / guide, page 76 · Parts diagram / guide, page 1
Manuals & Resources
Manuals & Resources
The Fits My System tab contains the source manuals and page references for each documented configuration. Open the complete reference there to review the original diagrams and requirements.