Spectra Watermakers

Spectra Watermakers 30A Double-Pole AC/DC Breaker EL-BRK-30ADP

$0.00
Current stock: 0
Item #: EL-BRK-30ADP
Availability: Usually Ships in 1-2 Business Days - Email us for Availability
Manuals & support

Start with your model’s parts diagram and the number on the installed part. Match any model, controls, voltage, or serial-range notes shown in this listing.

Spectra / Katadyn manufacturer support ↗
Overview

Overview

EL-BRK-30ADP is the 30A double-pole AC/DC toggle breaker shown with the Newport 700/1000 24V DC feed-pump arrangement.

The older MkII drawing also labels this part for 110V AC and 24V DC versions. Its location and rating must be checked against the specific system revision.

This is a circuit-protection part. Match the existing approved breaker and diagram; a 30A label does not make it a replacement for the 10A or 15A listings.

Specifications & Contents

Specifications & Contents

Part numberEL-BRK-30ADP
Manufacturer designation30A; double-pole; AC/DC toggle breaker
Documented exampleNewport 700/1000 24V DC module
Fits My System

Fits My System

This is a circuit-protection part. Match the existing approved breaker and diagram; a 30A label does not make it a replacement for the 10A or 15A listings.

Select your configuration to see its requirements, or open the complete reference below.

All documented configurations and requirements

Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.

Documented configurations

  • Newport 1000 Mk II · MPC 5000 · Match installed voltage and hardware
  • Newport 700 Mk II · MPC 5000 · Match installed voltage and hardware

30A double-pole breaker specified for the legacy 110VAC circuit. This legacy assignment must not be copied into newer Connect wiring. System input: 110 V; retain the specified component supply and wiring.

Parts diagram / guide, page 62

Documented configurations

  • Newport 1000 Mk II · MPC 5000 · Match installed voltage and hardware
  • Newport 700 Mk II · MPC 5000 · Match installed voltage and hardware

The legacy diagram explicitly also assigns the 30A breaker to 24V DC. Match the original Mk II electrical assembly. System input: 24 V; retain the specified component supply and wiring.

Parts diagram / guide, page 62

Documented configurations

  • Newport 1000 Mk II-Z · MPC 5000 · Match installed voltage and hardware
  • Newport 700 Mk II-Z · MPC 5000 · Match installed voltage and hardware

30A double-pole breaker specified for the legacy 110VAC circuit. This legacy assignment must not be copied into newer Connect wiring. System input: 110 V; retain the specified component supply and wiring.

Parts diagram / guide, page 88

Documented configurations

  • Newport 1000 Mk II-Z · MPC 5000 · Match installed voltage and hardware
  • Newport 700 Mk II-Z · MPC 5000 · Match installed voltage and hardware

30A double-pole breaker in the documented Mk II-Z 24V DC assembly. System input: 24 V; retain the specified component supply and wiring.

Parts diagram / guide, page 87

Documented configurations

  • Newport 1000C · Connect · 24 VDC · Standard / long membranes · NP-1000C-24
  • Newport 700C · Connect · 24 VDC · Standard / long membranes · NP-700C-24

Newport 700/1000 24V electrical module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. System input: 24V; retain the documented component supply and wiring. 24V module; control board needs correct model firmware. Historical PWMA24-to-PWMA order-code equivalence remains a separate issue.

Parts diagram / guide, page 97