Spectra Watermakers

Spectra Watermakers OFFSHORE KIT FOR 20% KIT-OFFSH1

$1,102.00
Current stock: 0
Item #: KIT-OFFSH1
Availability:
Manuals & support

Start with your model’s parts diagram and the number on the installed part. Match any model, controls, voltage, or serial-range notes shown in this listing.

Spectra / Katadyn manufacturer support ↗
Overview

Overview

KIT-OFFSH1 provides a selection of repair parts and tools for the 20% Clark Pump used in documented Newport 700 and Newport 1000 systems. It combines seal replacement and reversing-mechanism work with tubing-repair supplies and membrane cleaners.

If the planned repair requires cylinder pistons or piston rods, those parts are outside this kit’s stated contents. Compare the 20% distributor rebuild kit before choosing a repair scope.

Specifications & Contents

Specifications & Contents

Part numberKIT-OFFSH1
Pump ratio20%
Pump partsSeal and O-ring kit, annular rings and reversing-valve spool
Plumbing suppliesNylon high-pressure tubing section and high-pressure fittings
Membrane cleanersAcid and alkaline
Tools / instructionsHex wrenches, O-ring pick, annular-ring tool and Clark Pump rebuild manual
ExcludedPiston rods and cylinder pistons
Fits My System

Fits My System

The current manufacturer page confirms 20% Newport 700/1000 applications. The older product URL includes “15-and-20,” but that wording alone does not verify a 15% installation; use the pump’s actual identification and parts drawing.

Select your configuration to see its requirements, or open the complete reference below.

All documented configurations and requirements

Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.

Documented configurations

  • Newport 1000 Mk II · MPC 5000 · Match installed voltage and hardware
  • Newport 1000 Mk II-Z · MPC 5000 · Match installed voltage and hardware
  • Newport 1000 · MPC 3000 · Match installed voltage and hardware
  • Newport 1000C · Connect · 110 VAC · Standard / long membranes · NP-1000C-110
  • Newport 1000C · Connect · 220 VAC · Standard / long membranes · NP-1000C-220
  • Newport 1000C · Connect · 24 VDC · Standard / long membranes · NP-1000C-24
  • Newport 1000C · Connect · 48 VDC · Standard / long membranes · NP-1000C-48
  • Newport 700 Mk II · MPC 5000 · Match installed voltage and hardware
  • Newport 700 Mk II-Z · MPC 5000 · Match installed voltage and hardware
  • Newport 700 · MPC 3000 · Match installed voltage and hardware
  • Newport 700C · Connect · 110 VAC · Standard / long membranes · NP-700C-110
  • Newport 700C · Connect · 220 VAC · Standard / long membranes · NP-700C-220
  • Newport 700C · Connect · 24 VDC · Standard / long membranes · NP-700C-24
  • Newport 700C · Connect · 48 VDC · Standard / long membranes · NP-700C-48

Installed 20% Clark Pump; select full rebuild or offshore kit according to the service required.

Parts diagram / guide, page 5 · Parts diagram / guide, page 6

Documented configurations

  • Newport 1000 Mk II · MPC 5000 · Match installed voltage and hardware
  • Newport 700 Mk II · MPC 5000 · Match installed voltage and hardware

Corrected against the newer Clark guide: installed 20% Newport 700/1000 pump requires KIT-OFFSH1.

Parts diagram / guide, page 6 · Parts diagram / guide, page 5 · Parts diagram / guide, page 6

Documented configurations

  • Newport 1000 Mk II-Z · MPC 5000 · Match installed voltage and hardware
  • Newport 700 Mk II-Z · MPC 5000 · Match installed voltage and hardware

For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Parts diagram / guide, page 49

Documented configurations

  • Newport 1000 · MPC 3000 · Match installed voltage and hardware
  • Newport 700 · MPC 3000 · Match installed voltage and hardware

Corrected against the newer Clark guide: installed 20% Newport 700/1000 pump requires KIT-OFFSH1.

Parts diagram / guide, page 46 · Parts diagram / guide, page 5 · Parts diagram / guide, page 6

Documented configurations

  • Newport 1000C · Connect · 110 VAC · Standard / long membranes · NP-1000C-110
  • Newport 1000C · Connect · 220 VAC · Standard / long membranes · NP-1000C-220
  • Newport 1000C · Connect · 24 VDC · Standard / long membranes · NP-1000C-24
  • Newport 1000C · Connect · 48 VDC · Standard / long membranes · NP-1000C-48
  • Newport 700C · Connect · 110 VAC · Standard / long membranes · NP-700C-110
  • Newport 700C · Connect · 220 VAC · Standard / long membranes · NP-700C-220
  • Newport 700C · Connect · 24 VDC · Standard / long membranes · NP-700C-24
  • Newport 700C · Connect · 48 VDC · Standard / long membranes · NP-700C-48

For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Parts diagram / guide, page 58

Manuals & Resources
Reviews

Customer reviews

Be the first to review this product.