SPECTRA OWNER GUIDE

Newport 1000 MPC parts & owner guide

Identify the original filter stages, three-quarter-HP feed module and 20% Clark Pump. Find labeled drawings and current upgrade paths for the controller, probe, valve and pump hardware actually installed.

Original MPC generation · 24V DC / 110V AC / 220V AC layouts

Have a Newport 700 MPC? Open its guide →

Your installed system

Record main feed power separately from the DC supply to the controls.

Identify both power inlets on AC systems.

Confirm actual dimensions, count and end caps.

Identify main feed power and controls.

CHECK GENERATION AND CHANGED EQUIPMENT

Make sure this is the original MPC Newport

Original guide, not Mk II-Z or Connect

The manufacturer index groups original Newport 700/1000 MPC manuals under 2006–2009; its supplied original file is dated September 22, 2005 and documents MPC-3000. The original layout includes a 50-micron intake filter and no separate intake booster. Later Mk II / Mk II-Z and Connect modules differ.

Choose the correct manual generation ↗

Read the actual controls

Systems shipped after February 23, 2006 could use MPC-5000, and many older units have already been converted. The panel name or the system year alone does not establish the board now installed. Record chip, control supply and prior modifications.

AC feed power is not control voltage

The AC model has an AC motor-power inlet and a separate DC controls inlet. Its VFD produces three-phase motor power. The documented DC main-feed version is 24V. A 12V control supply on an AC machine does not make the main motor a 12V motor.

DC version ↗ · AC version ↗

FILTER DIMENSIONS AND THE ORIGINAL FLOW PATH

Four different filter functions

Original seawater path: sea strainer → 50-micron intake filter → main feed pump → 20-micron filter → 5-micron filter → Clark Pump / membranes. The carbon element is on the separate freshwater-flush path. Trace the actual plumbing after any retrofit; later boosted layouts place the fine filters differently.

StagePart and sizeFunction / location
Coarse seawater intakeFT-FTC-50
10-inch housing format; exact cartridge length / diameter require confirmation
Before the main feed pump in the original low-pressure intake module.
First fine-sediment stageFT-FTC-20
Nominal 10 in long × 2.5 in diameter
First of the pump-module fine filters, before the 5-micron stage.
Second fine-sediment stageFT-FTC-5
Nominal 10 in long × 2.5 in diameter
Downstream of the 20-micron filter in the original pressurized filter pair.
Freshwater-flush chlorine protectionFT-FTC-CC
Nominal 10 in long × 2.5 in diameter
Domestic freshwater flush path; a separate carbon function.

Sizes are nominal, not guaranteed end-to-end measurements. Confirm actual cartridge ends and housing identity before substituting another make. The reviewed sources do not specify the exact FT-FTC-50 or optional oil/water element dimensions; confirm those measured sizes with Spectra.

Match the housing, seal and wrench

The original spares list names 10H housing seal for black pressurized filter bowls. The manufacturer matrix pairs FT-FTH-10H with that seal and 10H wrench; stainless 10H wrench is its separate option.

The original flush/intake drawing names clear FT-FTH-10L. The matrix does not separately establish its seal pairing. Do not infer LP10 from the adjacent discontinued housing column.

Changed clear three-piece housings

For an actually identified three-piece 10L3PCS housing, the matrix pairs 3PCS10 seal and 3PCS wrench. That does not prove a direct replacement for every original 10L or pressure-stage bowl. Confirm pressure rating and actual lid/bowl style with Spectra.

Oil/water stage depends on generation

The original manual substitutes the oil/water element for its 20-micron element. Later boosted manuals add a separate upstream housing. Confirm the installed generation and current filtration procedure with Spectra before changing the stages. Keep the documented 5-micron stage.

Original optional arrangement ↗
Spectra Filters, housing seals and wrenches matrix, PDF page 1

Filters, housing seals and wrenches matrix

Identify the pictured housing family. The discontinued FT-FTH-10 / FT-FHW-10 pair is separate from current high-pressure and three-piece families.

Open full-size source ↗
Original plumbing schematic ↗ · 5-micron dimensions ↗ · 20-micron dimensions ↗ · Carbon dimensions ↗

CONFIRM SIZE AND ORDER QUANTITY

Membrane element or vessel hardware?

A 40-inch kit replaces one element

KIT-MB-40F supplies one 2.5 × 40-inch element and replacement seals. It is a conditional reference for this older generation: the shared original manual pictures three vessels without an explicit model-specific size/count table.

Later Newport 1000 layouts use 3 long elements; that does not independently establish the count on your original machine. Confirm the actual dimensions, count and end caps with Spectra before ordering. The selector does not calculate a whole-system order.

Current single-element kit ↗ · Later model-specific layouts ↗

Identify a changed arrangement

Short elements, larger-diameter commercial membranes and different pressure-vessel stacks require their own identification. A model name does not establish that a retrofit uses the standard layout. Leave the membrane selector unknown until its actual dimensions are confirmed.

MAIN HEAD, MOTOR AND SPEED CONTROLLER

Know which part of the feed module you need

Original DC motor and controller gaps

The manual names EL-MTR-3/4D24 and EL-MTR-SPCDC / Winland speed control. Neither has an exact listing in this supplied catalog. The later one-HP 24V motor candidate needs a verified motor/coupling/controller conversion from Spectra.

The Newport 400 half-HP to 12V-motor bulletin is not used as a replacement route for this three-quarter-HP 700/1000 assembly.

Original run / flush speed control ↗

Sensors measure different locations

The original pressure sensors monitor the fine-filter pair; Rotoflo measures product-water flow before diversion. Verify range, units, connector and installed board with Spectra before replacing a sensor. A shared code is not proof of every electrical revision.

Original sensing functions ↗

CONTROLLER GENERATION AND ACTUAL SUPPLY

Salinity probe and MPC upgrade paths

The 2005 manual documents MPC-3000. Spectra’s upgrade manual states that MPC shipments before February 23, 2006 used that generation; later or already converted systems can have MPC-5000. Read the actual board and chip. SP1 is obsolete; SP4 alone does not work on MPC-3000.

Identify the installed controller.

Confirmed MPC-3000 conversion

Identify the DC control supply, including the separate supply on AC versions. The AC motor label does not select the conversion kit.

12V DC controls: Review the 12V MPC conversion

Confirm the installed Newport motor/controller, wiring re-termination and system programming with Spectra. The kit includes A40 board, SP4, Rotoflo and fittings; the 24V kit also includes a 12V flush solenoid.

24V DC controls: Review the 24V MPC conversion

Confirm the installed Newport motor/controller, wiring re-termination and system programming with Spectra. The kit includes A40 board, SP4, Rotoflo and fittings; the 24V kit also includes a 12V flush solenoid.

No conversion kit is selected until the DC control supply is identified.

The existing MPC display is retained. A40’s lowered flush output may change the required solenoid. This is a controls conversion, not a feed-pump or motor upgrade.

MPC-5000 B-series / A31

Spectra lists A40 board plus SP4 probe. Confirm wiring and system programming. The standalone board is not the whole MPC-3000 conversion.

MPC-5000 A34 / A35

SP4 needs the EL-MPC-SPCBA daughter board, or the A40 board plus SP4 route. The daughter board has no exact listing in this catalog. Confirm its availability and the actual interface with Spectra; the probe alone is insufficient.

MPC-5000 A36 / A37 / A39 / A40

SP4 is listed as compatible. Match actual connector and 15-foot cable reach. A36 is listed with or without the daughter board. The shorter SP4N suffix remains a separate confirmation.

Installed controlsCurrent routeBefore ordering
MPC-3000Eligible MPC-5000 conversion firstConfirm DC controls supply, wiring, motor interface and kit contents with Spectra.
MPC-5000 B## / A31A40 board plus SP4Confirm system programming and wiring.
MPC-5000 A34 / A35SP4 with daughter board, or A40 plus SP4Daughter board is required for the retained-board path.
MPC-5000 A36 / A37 / A39 / A40SP4 compatibleCheck exact connector, cable reach and actual chip.
Unknown / unlisted chipNo automatic recommendationIdentify the installed board with Spectra.

After the complete installation, use the calibration procedure for the installed controller and compare with a calibrated independent salinity meter. The original MPC-3000 manual uses a jumper/trimmer procedure; do not assume it applies to a converted board.

Original MPC-3000 calibration ↗ · Current chip / probe table ↗ · Current conversion contents ↗ · Wiring conversion instructions ↗

MATCH THE FUNCTION AND ACTUAL VALVE BODY

Intake manifold, flush valve or product diversion?

The original intake drawing uses SUB-NP-MNFC. The current body selector uses fitting-hole count and solenoid opening, not just model year; it does not establish every historical code as an exact alias.

Actual intake bodyCurrent chart referenceCheck before ordering
5 fitting holes; about 1-inch solenoid openingSUB-NP-MK2-INTMatch actual valve, opening, mounting and required adapter with Spectra.
6 fitting holes; about 1-inch solenoid openingSUB-NP-MK2-INEZMatch actual valve, opening, mounting and required adapter with Spectra.
6 fitting holes; about 3/4-inch Spartan openingSUB-NP-MK2-INTZMatch actual valve, opening, mounting and required adapter with Spectra.
Spectra Current Newport intake manifold selection, PDF page 1

Current Newport intake manifold selection

Count actual fitting holes and identify the valve opening. Legacy one-inch bodies need the appropriate adapter for a later Spartan valve.

Open full-size source ↗
Current flush / diversion replacement chart ↗

THE 20% ARRANGEMENT IS A DIFFERENT PUMP FAMILY

Clark Pump outside and internal parts

LOCATE THE PART BEFORE BUYING

Original labeled drawings and current ratio checks

Choose a section, then open its full-size PDF for readable callouts. Shared older pump drawings include several ratios; current 20% notes remain beside each illustration.

Showing all original assembly drawings.

Spectra Original seawater and flush schematic, PDF page 8

Original seawater and flush schematic

Original no-booster layout. Trace the separate 50-micron intake stage, pump-module fine filters and carbon flush path; changed plumbing must be identified on the boat.

Open full-size source ↗
Spectra 50-micron intake and carbon flush module, PDF page 66

50-micron intake and carbon flush module

The clear bowls have separate sediment and carbon functions. The original 10L seal pairing is not established by the adjacent standard-housing column in the current matrix.

Open full-size source ↗
Spectra Mechanical-drive feed pump and motor/controller labels, PDF page 63

Mechanical-drive feed pump and motor/controller labels

The original PL-PMP-240250 and three-quarter-HP motor are distinct from the later MAG5 head and motor conversions.

Open full-size source ↗
Spectra 24V DC control and speed-controller assembly, PDF page 19

24V DC control and speed-controller assembly

Identify the original Winland controller and relay arrangement. The Newport 400 half-HP motor conversion is not applied to this assembly.

Open full-size source ↗
Spectra AC feed power and separate DC controls inlet, PDF page 20

AC feed power and separate DC controls inlet

The VFD produces three-phase motor output. Identify the separate DC controls inlet before choosing a controller conversion kit.

Open full-size source ↗
Spectra Product diversion, SP1 probe and Rotoflo, PDF page 65

Product diversion, SP1 probe and Rotoflo

These are separate devices after the membranes. Historical valve suffixes require actual body/output confirmation; SP1 is now obsolete.

Open full-size source ↗
Spectra Original membrane mounting and optional Z-Brane hardware, PDF page 64

Original membrane mounting and optional Z-Brane hardware

The shared photo shows three vessels, not a model-specific count table. Confirm actual element size/count and end-cap revision for the older Newport 700 or 1000.

Open full-size source ↗
Spectra Clark Pump exterior and shared ratio callouts, PDF page 67

Clark Pump exterior and shared ratio callouts

Use the identified 20% pump. The shared CB7/10/15/20 drawing does not make those center blocks interchangeable.

Open full-size source ↗
Spectra Original shared reversing-valve drawing, PDF page 68

Original shared reversing-valve drawing

Older mixed labels include a 10VSA callout. Follow the current 20% spool assembly and one-inch bore/piston/seal references instead of selecting every pictured ratio.

Open full-size source ↗
Spectra Current 20% spool piston and one-inch seal pair, PDF page 20

Current 20% spool piston and one-inch seal pair

20% uses HP-TB-VSP1 and SO-HPP-SP1. The 7% / 10% larger-bore pair is separate.

Open full-size source ↗
Spectra Original center-block pilot and check-valve drawing, PDF page 69

Original center-block pilot and check-valve drawing

Shared older drawing; current 20% arrangement uses two 7/8-inch rods and four PR10 seal locations, not the single rod pictured for smaller ratios.

Open full-size source ↗
Spectra Current twin-rod 20% callout, PDF page 16

Current twin-rod 20% callout

The manufacturer explicitly names HP-CYL-7/8R ×2 for the 20% pump. Catalog pack quantity is checked separately.

Open full-size source ↗
Spectra Original cylinder and end-cap assembly, PDF page 70

Original cylinder and end-cap assembly

Current 20% pistons are Delrin with replaceable seal/bushing pieces. The original generic PT label does not establish the one-piece 7% / 10% piston as a substitute.

Open full-size source ↗

PLAN MAINTENANCE BY INSTALLED EQUIPMENT

Service supplies and onboard spares

Keep sediment and carbon functions separate

Replace dirty sediment elements according to condition and the current cartridge instructions. Historic washing advice is not a blanket recommendation for current elements. Maintain the original 50 / 20 / 5 stages until a documented retrofit establishes another layout. Replace carbon at least every six months.

Original maintenance ↗

Optional Z-Brane is not Z-Ion

The original optional Z-Brane equipment is fitted in the pressure vessels and requires its own electrical supply. A later Z-Ion bowl/generator retrofit is different equipment; no complete Z-Ion conversion is inferred from this manual. Confirm changed preservation hardware with Spectra. Neither equipment replaces freeze protection.

Original Z-Brane installation ↗
Low output: should I buy or clean a membrane?

Check intake restrictions, fitted filters, actual motor supply, pump flow, pressure and leaks first. Current manufacturer flow tests distinguish feed-pump delivery from Clark Pump recovery. Compare suspect salinity readings with a calibrated independent meter; keep product-diversion protection active.

Manufacturer 20% flow-test reference ↗

ANSWERS THAT CHANGE THE PART YOU NEED

Filter, controller and rebuild questions

Why are there 50-, 20- and 5-micron filters?

The original no-booster layout uses a 50-micron element before the main feed pump and a 20-then-5 fine-filter pair after it. Carbon is on the separate freshwater-flush path. Later boosted modules have a different layout; trace what is actually installed.

What filter dimensions are verified?

The current FT-FTC-20, FT-FTC-5 and FT-FTC-CC references specify nominal 10-inch length × 2.5-inch diameter. The original FT-FTC-50 uses a 10-inch-format housing, but exact cartridge dimensions are not independently specified in the reviewed sources. Confirm its measured dimensions and end style with Spectra.

Can the current MAG5 head replace the original head by itself?

The original mechanical-drive head and later magnetic-drive head have different drive arrangements. Confirm the installed motor, coupling, ports and approved conversion with Spectra. A matching 700/1000 model name is not proof of a bare-head substitution.

How do I choose the upgrade kit on an AC watermaker?

Identify the separate DC control supply and the actual MPC generation. Do not choose a 12V or 24V controls kit from the 110V / 220V AC motor input. Confirm the Newport wiring, motor-speed interface and programming with Spectra.

Does the MPC-5000 kit also upgrade the main feed pump?

No. The listed contents are A40 board, SP4, Rotoflo and fittings, plus a 12V flush solenoid in the 24V kit. The original display is retained. Feed-pump head, motor and speed-controller conversions are separate scopes.

Can I use a Newport 400 pump rebuild kit here?

The identified 20% Clark Pump uses its own block, twin rods, one-inch top-end family and replaceable-seal pistons. The 7% / 10% kits and larger-bore top-end parts are excluded. Check installed ratio and current contents before ordering.

How many membrane kits should I order?

One KIT-MB-40F replaces one confirmed 2.5 × 40-inch element. Later Newport 1000 layouts use 3 long elements, but the original shared manual does not independently establish a model-specific size/count table. Confirm actual elements, dimensions and end caps with Spectra; no whole-system quantity is selected automatically.

MODEL-SCOPED REFERENCES WITH THEIR REQUIREMENTS

Search parts and researched replacement paths

Named model and current manufacturer references appear first. Changed-hardware candidates remain separate and conditional. A selection does not verify a retrofit, live stock or price.

112 references.

SC-1

Storage Compound

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the model service reference on page 36. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Storage / preservation chemical for Spectra systems. Use the model manual for the required dose, circulation and recommissioning procedure. This is a maintenance consumable, not an installed component or an automatic recommendation to clean. Manufacturer current kit name: KIT-CHEM-SC1; this catalog listing uses SC-1.

Manual, page 36 ↗

View part & current price
SC-2

Alkaline Cleaning Compound

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the model service reference on page 41. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Alkaline membrane cleaner for biological fouling, compatible with Spectra systems. Use only when cleaning is indicated and follow your model manual for dose, temperature, circulation and flushing. This is a service consumable; do not mix cleaners. Manufacturer current kit name: KIT-CHEM-SC2; this catalog listing uses SC-2.

Manual, page 41 ↗

View part & current price
SC-3

Acid Cleaning Chemical

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the model service reference on page 41. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Acid membrane cleaner for mineral scale, compatible with Spectra systems. Use only when cleaning is indicated and follow your model manual for dose, temperature, circulation and flushing. This is a service consumable; do not mix cleaners. Manufacturer current kit name: KIT-CHEM-SC3; this catalog listing uses SC-3.

Manual, page 41 ↗

View part & current price
EL-MPC-RMCD

MPC LCD control display

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Historical MPC LCD / fluorescent display reference, with the existing panel retained during the documented MPC-5000 conversion. Match actual generation, connector, approved cable and current product scope with Spectra. An ordinary LAN or phone cable is not suitable.

Identification requirements & source

Historical MPC LCD / fluorescent display reference, with the existing panel retained during the documented MPC-5000 conversion. Match actual generation, connector, approved cable and current product scope with Spectra. An ordinary LAN or phone cable is not suitable.

Existing fitment requirements

  • legacy MPC LCD display identified in this model manual. Retain MPC controls and matching display cable; not a Connect touchscreen, VFD display alias or three-button Remote panel. Historical fitment is supported; current factory supply is not established by this diagram.

Manual, page 65 ↗

View part & current price
EL-MPC-SP

Salinity Probe

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Original SP1 probe reference; Spectra marks it obsolete since July 2023. This legacy listing does not establish available stock. Use the installed controller/chip path for current SP4 equipment; SP4 alone does not work on MPC-3000.

Identification requirements & source

Original SP1 probe reference; Spectra marks it obsolete since July 2023. This legacy listing does not establish available stock. Use the installed controller/chip path for current SP4 equipment; SP4 alone does not work on MPC-3000.

Manual, page 65 ↗

View part & current price
EL-SSR-IFM

Legacy inline flow sensor — confirm range

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Original Rotoflo product-water sensor before the diversion manifold; it measures product flow for MPC control. The current listing gives a 0.5–5 range, without this source establishing identical units, connector or revision for the older sensor. Confirm range, harness and calibration with Spectra. The current MPC conversion kit already supplies a flow meter.

Identification requirements & source

Original Rotoflo product-water sensor before the diversion manifold; it measures product flow for MPC control. The current listing gives a 0.5–5 range, without this source establishing identical units, connector or revision for the older sensor. Confirm range, harness and calibration with Spectra. The current MPC conversion kit already supplies a flow meter.

Existing fitment requirements

  • Standard-range inline sensor in the documented Catalina/Newport product-water module. Match 0.5–5 L/min range and 3/8-inch NPT ports. Replacement EL-SSR-IFM is supplied with bare wires per the 2023 bulletin; Molex-terminated assembly is SUB-MPC-IFA. Match the installed connection before ordering. Standard sensor: 0.5–5 L/min, 3/8-inch NPT; Molex assembly SUB-MPC-IFA. The 2023 marine Connect production change uses a three-pin Deutsch connector; replacement bare-sensor SKU is supplied with bare wires. Do not assume an order arrives with a Deutsch plug.

Manual, page 65 ↗

View part & current price
EL-SWT-VC

Vacuum Switch

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the feed-pump module on page 63. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Original direct-drive Newport Mk I assembly. Motor is the three-phase AC motor used with its drive; retain this generation and vacuum-switch arrangement. System input: 110/220 V; retain the specified component supply and wiring.

Manual, page 63 ↗

View part & current price
EL-TM-1/4PPCP

1/4" Cable Cap Stud Insulator (Black)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the membrane vessel and mounting assembly on page 64. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Manual, page 64 ↗

View part & current price
FT-FTC-20

20 Micron Filter

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

Original first fine-sediment stage on the pump module, followed by FT-FTC-5. The original no-booster layout places the fine-filter pair after the main feed pump. Current manufacturer nominal size: 10 inches long × 2.5 inches diameter. Identify the actual black pressure housing and end style.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 40 ↗

View part & current price
FT-FTC-5

5 Micron Filter

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

Original second fine-sediment stage, downstream of FT-FTC-20 on the pump module. Current manufacturer nominal size: 10 inches long × 2.5 inches diameter. This is not the 50-micron intake stage or the carbon freshwater-flush filter.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 40 ↗

View part & current price
FT-FTC-50

50 Micron Filter Element

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Original 50-micron intake element in the low-pressure flush/intake module, upstream of the main feed pump. It is a separate coarse sediment stage, not the carbon flush element. The manual uses a 10-inch-format housing but does not specify this cartridge’s exact length or diameter. Confirm measured cartridge dimensions and end style with Spectra before substituting another brand.

Identification requirements & source

Original 50-micron intake element in the low-pressure flush/intake module, upstream of the main feed pump. It is a separate coarse sediment stage, not the carbon flush element. The manual uses a 10-inch-format housing but does not specify this cartridge’s exact length or diameter. Confirm measured cartridge dimensions and end style with Spectra before substituting another brand.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 66 ↗

View part & current price
FT-FTC-CC

Carbon Filter

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

Carbon element in the separate freshwater-flush path, protecting the membrane from chlorine in domestic water. Current manufacturer nominal size: 10 inches long × 2.5 inches diameter. Replace at least every six months under the model manual; it does not replace a sediment filter.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 66 ↗

View part & current price
FT-FTC-OW

Oil Water Separator Filter

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. The original manual describes replacing the 20-micron cartridge with the oil/water element in its duplex filter set. Later boosted Newport manuals instead specify an added upstream housing. Confirm the installed generation and revised filtration procedure with Spectra before changing stages. Exact oil/water cartridge dimensions are not supplied by this source; verify the actual element and housing.

Identification requirements & source

The original manual describes replacing the 20-micron cartridge with the oil/water element in its duplex filter set. Later boosted Newport manuals instead specify an added upstream housing. Confirm the installed generation and revised filtration procedure with Spectra before changing stages. Exact oil/water cartridge dimensions are not supplied by this source; verify the actual element and housing.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 40 ↗

View part & current price
FT-FTH-10L

Low Pres. Filter Housing(Clr)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Original clear low-pressure housing named on the intake/flush module, separate from the black pressurized fine-filter bowls. The current matrix gives no separate seal/wrench pairing directly below this 10L column. Do not infer SO-FHS-LP10 from the adjacent discontinued standard housing column.

Identification requirements & source

Original clear low-pressure housing named on the intake/flush module, separate from the black pressurized fine-filter bowls. The current matrix gives no separate seal/wrench pairing directly below this 10L column. Do not infer SO-FHS-LP10 from the adjacent discontinued standard housing column.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Manual, page 66 ↗

View part & current price
FT-STN-6S

6" Strainer Screen (Large)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the model service reference on page 46. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 46 ↗

View part & current price
FT-PV-ER

Membrane Ring

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Vessel hardware is separate from the membrane element. The original drawing includes FT-PV-ZEP / FT-PV-ZEPB Z-Brane end-cap hardware; later diagrams name KIT-PV-25EP1. Confirm the actual end-cap, ring and electrode arrangement with Spectra before assuming the later kit replaces an original assembly. Do not disturb Z-Brane high-voltage wiring.

Identification requirements & source

Vessel hardware is separate from the membrane element. The original drawing includes FT-PV-ZEP / FT-PV-ZEPB Z-Brane end-cap hardware; later diagrams name KIT-PV-25EP1. Confirm the actual end-cap, ring and electrode arrangement with Spectra before assuming the later kit replaces an original assembly. Do not disturb Z-Brane high-voltage wiring.

Existing fitment requirements

  • ring/U-tube/nipple in the illustrated historical vessel assembly, including its Z-brane options. Do not generalize end-cap or rigid-tube replacements from these labels. Requires the illustrated standard long-vessel arrangement; compact and altered tube layouts are outside this mapping.

Manual, page 64 ↗

View part & current price
FT-PV-UTC

Pressure Vessel U-Tube Connector

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the membrane vessel and mounting assembly on page 64. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • ring/U-tube/nipple in the illustrated historical vessel assembly, including its Z-brane options. Do not generalize end-cap or rigid-tube replacements from these labels. Requires the illustrated standard long-vessel arrangement; compact and altered tube layouts are outside this mapping.

Manual, page 64 ↗

View part & current price
HP-CB-CV

Check Valve

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
HP-CB-CVR

Check Valve Retainer

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
HP-CB-CVS

Check Valve Seat

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
HP-CB-PPS

Pilot Valve Pin

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
HP-CB-PVCR

Pilot Valve Clip Ring

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
HP-CB-PVS

Pilot Valve Spool

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
HP‐CYL‐CCA

Cylinder Assembly (G‐10 BASE)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the Clark Pump outside on page 67. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 67 ↗

View part & current price
HP‐CYL‐EC

Cylinder End Cap

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the Clark Pump outside on page 67. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 67 ↗

View part & current price
HP‐CYL‐R

Cylinder End Ring

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the Clark Pump outside on page 67. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 67 ↗

View part & current price
HP-CYL-SST

Stainless Tube

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the Clark Pump outside on page 67. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 67 ↗

View part & current price
HP‐TB‐BV

Bleed Valve

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the Clark Pump outside on page 67. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 67 ↗

View part & current price
HP‐TB‐VB

Valve Body

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the Clark Pump outside on page 67. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 67 ↗

View part & current price
PL-CKV-1/4M-F

1/4" Plastic Ck Valve (M-F)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the product-water diversion / sensing assembly on page 65. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 65 ↗

View part & current price
PL-FTE-1/4X1/4P

1/4" Fpt X 1/4"Tube Fitting Ell

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the membrane vessel and mounting assembly on page 64. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Manual, page 64 ↗

View part & current price
PL-HBE-3/4X1/2

3/4" Npt X 1/2"Hose Barb Ell. Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the intake / freshwater-flush module on page 66. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 66 ↗

View part & current price
PL-HBE-3/4X3/4

3/4" Npt X 3/4" Hose Barb Ell Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the intake / freshwater-flush module on page 66. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 66 ↗

View part & current price
PL-HBS-3/4X3/4

3/4" Npt X 3/4" Hose Barb St. Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the intake / freshwater-flush module on page 66. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 66 ↗

View part & current price
PL-HS-3/4SH

3/4" Reinforce Suction Hose

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the feed-pump module on page 63. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Length is not established; measure the run and retain the specified hose/tube duty.

Manual, page 63 ↗

View part & current price
PL-MTS-1/4X1/4P

1/4" Male NPT x 1/4" Tube Straight

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the product-water diversion / sensing assembly on page 65. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 65 ↗

View part & current price
PL-MTS-3/8X1/2S

Pl-Mts-3/8X1/2S

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the cylinder assembly on page 70. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Manual, page 70 ↗

View part & current price
PL-NLT-1/2HP

1/2" High Pressure Tube (Dayco) (Per Foot)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the feed-pump module on page 63. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Length is not established; measure the run and retain the specified hose/tube duty.

Manual, page 63 ↗

View part & current price
PL-NLT-1/4LP

1/4" Low Pressure Tube (Product) (Per Foot)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the membrane vessel and mounting assembly on page 64. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Manual, page 64 ↗

View part & current price
PL-NLT-3/8LP

3/8" Low Pressure Tube (Product) (Per Foot)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the product-water diversion / sensing assembly on page 65. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Length is not established; measure the run and retain the specified hose/tube duty.

Manual, page 65 ↗

View part & current price
PL-NP-1/8N

1/8"Npt Close Nipple Nylon

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the membrane vessel and mounting assembly on page 64. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • ring/U-tube/nipple in the illustrated historical vessel assembly, including its Z-brane options. Do not generalize end-cap or rigid-tube replacements from these labels. Requires the illustrated standard long-vessel arrangement; compact and altered tube layouts are outside this mapping.

Manual, page 64 ↗

View part & current price
PL-QDC-BD3/8

3/8"Npt Quick Discnt. Coup. Body

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the intake / freshwater-flush module on page 66. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 66 ↗

View part & current price
PL-QDC-HB5/8

5/8" Quick Discnt. Fitt. Hose Barb

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the intake / freshwater-flush module on page 66. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 66 ↗

View part & current price
PL-VLV-3W3/4

3/4" 3-Way Valve

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the intake / freshwater-flush module on page 66. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Manual, page 66 ↗

View part & current price
SUB-NP-DVM

Diversion Valve Manifold

24V DC / 110V AC / 220V AC layout references · Named in model manual

Confirm with Spectra before ordering. Product-water diversion manifold named on original page 65, carrying salinity/flow/diversion equipment. Match retained valve-body design and ports with Spectra. This is separate from the intake manifold on the feed pump.

Identification requirements & source

Product-water diversion manifold named on original page 65, carrying salinity/flow/diversion equipment. Match retained valve-body design and ports with Spectra. This is separate from the intake manifold on the feed pump.

Manual, page 65 ↗

View part & current price
EL-MTR-3/4AC220

3/4 Hp, 240 Vac, 3 Phase, 56C Motor

110V / 220V AC feed-power layouts · Named in model manual

Confirm with Spectra before ordering. Original three-quarter-HP, 240VAC three-phase motor reference. On AC models the VFD accepts the selected boat supply and produces three-phase motor power. Identify VFD, motor plate, phase, frame and coupling with Spectra; a 110V system label does not call for a 110V motor directly connected to mains.

Identification requirements & source

Original three-quarter-HP, 240VAC three-phase motor reference. On AC models the VFD accepts the selected boat supply and produces three-phase motor power. Identify VFD, motor plate, phase, frame and coupling with Spectra; a 110V system label does not call for a 110V motor directly connected to mains.

Existing fitment requirements

  • Original direct-drive Newport Mk I assembly. Motor is the three-phase AC motor used with its drive; retain this generation and vacuum-switch arrangement. System input: 110/220 V; retain the specified component supply and wiring.

Manual, page 63 ↗

View part & current price
KIT-BCK-C

Cruise Kit C

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

Original Cruise Kit C reference includes the 50-, 20- and 5-micron filters and storage compound listed in this older manual. Check current product contents and quantities before adding loose elements. The later two-stage Cruise Kit B is not automatically equivalent for the original 50-micron layout.

Existing fitment requirements

  • Cruise consumables kit; confirm current kit contents and installed filter stages. Carry-on spares quantity is not system installation quantity.

Manual, page 46 ↗

View part & current price
HP-CB-PVPS

Pilot Valve Pin Seal

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
SO-HPP-CVS

Check Valve Seat Seal

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
SO-HPP-ECCB

End Cap Center Block Seal

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
SO-HPP-PLP

Pilot Ports Seal

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the reversing-valve assembly on page 68. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 68 ↗

View part & current price
SO-HPP-PS

Pin Seals

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
SO-HPP-PV

Pilot Valve Seal

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the center-block assembly on page 69. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 69 ↗

View part & current price
SO-HPP-RV

Relief Valve Seal

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the reversing-valve assembly on page 68. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 68 ↗

View part & current price
SO-HPP-VB

Valve Bore Seal

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the reversing-valve assembly on page 68. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 68 ↗

View part & current price
SO-HPP-VP

Valve Port Seal

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the reversing-valve assembly on page 68. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 68 ↗

View part & current price
SO-STN-6SS

6" Strainer Seal (Big)

24V DC / 110V AC / 220V AC layout references · Named in model manual

Identification requirements & source

The September 2005 manual names this part in the model service reference on page 46. Match the actual assembly location, connection and installed revision; retain the manufacturer callout when identifying an older part.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 46 ↗

View part & current price
HP-CB-CB20

Center Block 20% (W/O Inserts)

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current 20% pump arrangement: CB20 center block, two 7/8-inch piston rods and four PR10 rod-seal locations. The rods/seals share 10% part codes but the twin-rod block and arrangement differ. Match actual pump ratio, revision and supplied pack quantity; do not substitute CB10 or a one-inch rod.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 37 ↗

View part & current price
HP-CB-CVSW

Check Valve Spring Washer

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current Clark Pump rebuild reference for the identified 20% arrangement. Match the 20% callout and actual installed revision. Drawing quantities describe locations; the product page determines supplied pack quantity.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
HP-CB-INS

Center Block Insert

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current Clark Pump rebuild reference for the identified 20% arrangement. Match the 20% callout and actual installed revision. Drawing quantities describe locations; the product page determines supplied pack quantity.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
HP-CB-SPR

Check Valve Spring

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current Clark Pump rebuild reference for the identified 20% arrangement. Match the 20% callout and actual installed revision. Drawing quantities describe locations; the product page determines supplied pack quantity.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 15 ↗

View part & current price
HP‐CYL‐7/8R

Piston Rod (10%)

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current 20% pump arrangement: CB20 center block, two 7/8-inch piston rods and four PR10 rod-seal locations. The rods/seals share 10% part codes but the twin-rod block and arrangement differ. Match actual pump ratio, revision and supplied pack quantity; do not substitute CB10 or a one-inch rod.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 16 ↗

View part & current price
HP‐CYL‐PT20

Piston 20%

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

The 20% piston is Delrin with replaceable piston seal and bushing; it differs from the one-piece 7% / 10% piston. Compare the complete 20PTA assembly with the loose PT20 piston and current seal/bushing callouts before duplicating pieces. The May 2024 manual uses separately named seal/bushing parts; confirm the historical SO-HPP-PT20 O-ring scope with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 72 ↗

View part & current price
HP‐CYL‐PTB20

Piston Bushing (20%)

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current Clark Pump rebuild reference for the identified 20% arrangement. Match the 20% callout and actual installed revision. Drawing quantities describe locations; the product page determines supplied pack quantity.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 17 ↗

View part & current price
HP‐TB‐ARP

Annular Ring (Peek)

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current Clark Pump rebuild reference for the identified 20% arrangement. Match the 20% callout and actual installed revision. Drawing quantities describe locations; the product page determines supplied pack quantity.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 19 ↗

View part & current price
HP‐TB‐VEB‐A

Valve End Block A 1" BORE, 20% CP

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

20% top-end family: A / B end blocks have one-inch bores, with HP-TB-VSP1 spool pistons and SO-HPP-SP1 seals. A1 / B1 blocks and the larger 7% / 10% spool parts belong to a different family. Match the actual side, bore and part revision.

Manual, page 61 ↗

View part & current price
HP‐TB‐VEB‐B

Valve End Block B 1" BORE, 20% CP

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

20% top-end family: A / B end blocks have one-inch bores, with HP-TB-VSP1 spool pistons and SO-HPP-SP1 seals. A1 / B1 blocks and the larger 7% / 10% spool parts belong to a different family. Match the actual side, bore and part revision.

Manual, page 61 ↗

View part & current price
SO-HPP-CVP1

Check Valve Port (Viton)

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current Clark Pump rebuild reference for the identified 20% arrangement. Match the 20% callout and actual installed revision. Drawing quantities describe locations; the product page determines supplied pack quantity.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 16 ↗

View part & current price
HP‐CYL‐PTS20

Piston Seal (20%)

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current Clark Pump rebuild reference for the identified 20% arrangement. Match the 20% callout and actual installed revision. Drawing quantities describe locations; the product page determines supplied pack quantity.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 17 ↗

View part & current price
SO-HPP-AR1

Annular Ring O-Ring (Viton)

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current Clark Pump rebuild reference for the identified 20% arrangement. Match the 20% callout and actual installed revision. Drawing quantities describe locations; the product page determines supplied pack quantity.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 19 ↗

View part & current price
SO-HPP-PR10

Piston Rod Seal

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

Current 20% pump arrangement: CB20 center block, two 7/8-inch piston rods and four PR10 rod-seal locations. The rods/seals share 10% part codes but the twin-rod block and arrangement differ. Match actual pump ratio, revision and supplied pack quantity; do not substitute CB10 or a one-inch rod.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 40 ↗

View part & current price
SO-HPP-SP1

Spool Piston O-Ring 1"

24V DC / 110V AC / 220V AC layout references · Clark Pump rebuild reference

Identification requirements & source

20% top-end family: A / B end blocks have one-inch bores, with HP-TB-VSP1 spool pistons and SO-HPP-SP1 seals. A1 / B1 blocks and the larger 7% / 10% spool parts belong to a different family. Match the actual side, bore and part revision.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 20 ↗

View part & current price
EL-MPC-PCBDPA40

MPC-5000 circuit board, A40

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Replacement A40 MPC-5000 board for an actually identified MPC-5000 installation. It is not the complete MPC-3000 conversion kit. Match wiring, control supply, motor-speed interface and system programming with Spectra.

Identification requirements & source

Replacement A40 MPC-5000 board for an actually identified MPC-5000 installation. It is not the complete MPC-3000 conversion kit. Match wiring, control supply, motor-speed interface and system programming with Spectra.

Manufacturer / research reference ↗

View part & current price
EL-MPC-SP4

SP4 salinity probe, 15-foot cable

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. SP4 with 15-foot cable. MPC-3000 must first be converted to eligible MPC-5000 controls. On an installed MPC-5000 board, B-series/A31 require A40 board plus SP4; A34/A35 require a daughter board or A40 route; A36/A37/A39/A40 list SP4. Match actual chip, connector and reach. The conversion kit already includes a probe.

Identification requirements & source

SP4 with 15-foot cable. MPC-3000 must first be converted to eligible MPC-5000 controls. On an installed MPC-5000 board, B-series/A31 require A40 board plus SP4; A34/A35 require a daughter board or A40 route; A36/A37/A39/A40 list SP4. Match actual chip, connector and reach. The conversion kit already includes a probe.

Manufacturer / research reference ↗

View part & current price
FT-FHW-10H

H. P. Filter Housing Wrench

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Black high-pressure 10H housing family for the pressurized fine-filter stage: FT-FTH-10H uses SO-FHS-10H and FT-FHW-10H, with the 10HSS stainless wrench option. The model spares list names SO-FHS-10H. Match the actual black bowl and lid; a clear three-piece seal is a different family.

Identification requirements & source

Black high-pressure 10H housing family for the pressurized fine-filter stage: FT-FTH-10H uses SO-FHS-10H and FT-FHW-10H, with the 10HSS stainless wrench option. The model spares list names SO-FHS-10H. Match the actual black bowl and lid; a clear three-piece seal is a different family.

Manual, page 1 ↗

View part & current price
FT-FHW-10HSS

High Pressure Filter Housomg Wrench Ss.

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Black high-pressure 10H housing family for the pressurized fine-filter stage: FT-FTH-10H uses SO-FHS-10H and FT-FHW-10H, with the 10HSS stainless wrench option. The model spares list names SO-FHS-10H. Match the actual black bowl and lid; a clear three-piece seal is a different family.

Identification requirements & source

Black high-pressure 10H housing family for the pressurized fine-filter stage: FT-FTH-10H uses SO-FHS-10H and FT-FHW-10H, with the 10HSS stainless wrench option. The model spares list names SO-FHS-10H. Match the actual black bowl and lid; a clear three-piece seal is a different family.

Manual, page 1 ↗

View part & current price
FT-FTH-10H

High Pressure Filter Housing (Blk)

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Black high-pressure 10H housing family for the pressurized fine-filter stage: FT-FTH-10H uses SO-FHS-10H and FT-FHW-10H, with the 10HSS stainless wrench option. The model spares list names SO-FHS-10H. Match the actual black bowl and lid; a clear three-piece seal is a different family.

Identification requirements & source

Black high-pressure 10H housing family for the pressurized fine-filter stage: FT-FTH-10H uses SO-FHS-10H and FT-FHW-10H, with the 10HSS stainless wrench option. The model spares list names SO-FHS-10H. Match the actual black bowl and lid; a clear three-piece seal is a different family.

Manual, page 1 ↗

View part & current price
KIT-HP-20PTA

20% Piston Assembly

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Identification requirements & source

The 20% piston is Delrin with replaceable piston seal and bushing; it differs from the one-piece 7% / 10% piston. Compare the complete 20PTA assembly with the loose PT20 piston and current seal/bushing callouts before duplicating pieces. The May 2024 manual uses separately named seal/bushing parts; confirm the historical SO-HPP-PT20 O-ring scope with Spectra.

Manual, page 96 ↗

View part & current price
KIT-HP-20VSA

Rev. Valve Spool Assembly (20%)

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Identification requirements & source

20% reversing-valve spool assembly reference. The older shared drawing labels KIT-HP-10VSA, while the later parts reference explicitly distinguishes the 20VSA route. Match actual annular-ring and spool revision; a larger shared drawing does not authorize the 10% assembly.

Manual, page 94 ↗

View part & current price
SUB-NP-MK2-INEZ

Newport Intake Manifold Eci Z-Ion

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Current intake-manifold selection: six fitting holes and about a 1-inch legacy valve opening. The original manual uses SUB-NP-MNFC, which is not established as an exact alias for all three modern bodies. Count the actual holes and identify valve port, mounting, adapter and fittings with Spectra. This intake manifold is separate from the product-water diversion manifold.

Identification requirements & source

Current intake-manifold selection: six fitting holes and about a 1-inch legacy valve opening. The original manual uses SUB-NP-MNFC, which is not established as an exact alias for all three modern bodies. Count the actual holes and identify valve port, mounting, adapter and fittings with Spectra. This intake manifold is separate from the product-water diversion manifold.

Existing fitment requirements

  • Six-hole manifold with legacy 1-inch ECI/Alcon solenoid opening; different from INTZ. Spartan conversion requires an adapter. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid.

Manufacturer / research reference ↗

View part & current price
SUB-NP-MK2-INT

Newport Manifold Eci Pre Z-Ion

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Current intake-manifold selection: five fitting holes and about a 1-inch legacy valve opening. The original manual uses SUB-NP-MNFC, which is not established as an exact alias for all three modern bodies. Count the actual holes and identify valve port, mounting, adapter and fittings with Spectra. This intake manifold is separate from the product-water diversion manifold.

Identification requirements & source

Current intake-manifold selection: five fitting holes and about a 1-inch legacy valve opening. The original manual uses SUB-NP-MNFC, which is not established as an exact alias for all three modern bodies. Count the actual holes and identify valve port, mounting, adapter and fittings with Spectra. This intake manifold is separate from the product-water diversion manifold.

Existing fitment requirements

  • Five-hole manifold and legacy 1-inch ECI/Alcon solenoid opening. Current Spartan solenoid requires the appropriate adapter. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid.

Manufacturer / research reference ↗

View part & current price
SUB-NP-MK2-INTZ

Newport Mk-Ii Intake Manifold Z-Ion

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Current intake-manifold selection: six fitting holes and about a 3/4-inch Spartan opening. The original manual uses SUB-NP-MNFC, which is not established as an exact alias for all three modern bodies. Count the actual holes and identify valve port, mounting, adapter and fittings with Spectra. This intake manifold is separate from the product-water diversion manifold.

Identification requirements & source

Current intake-manifold selection: six fitting holes and about a 3/4-inch Spartan opening. The original manual uses SUB-NP-MNFC, which is not established as an exact alias for all three modern bodies. Count the actual holes and identify valve port, mounting, adapter and fittings with Spectra. This intake manifold is separate from the product-water diversion manifold.

Existing fitment requirements

  • Six external fitting holes and approximately 3/4-inch top threaded solenoid port. Identify installed manifold, not model year alone. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid. Match hole count AND solenoid-port diameter to the installed manifold. An adapter may be required for a changed solenoid.

Manufacturer / research reference ↗

View part & current price
PL-PMP-240MAG5

240MAG5 magnetic-drive feed-pump head — confirm conversion

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Current manufacturer feed-pump head reference for Newport 700/1000, separate from motor and speed controller. The original drawing names PL-PMP-240250, a mechanically coupled head. This MAG5 magnetic-drive head requires confirmation of the installed motor/coupling, drive arrangement, ports and approved conversion with Spectra; it is not proven to be a bare-head drop-in for the 2005 assembly.

Identification requirements & source

Current manufacturer feed-pump head reference for Newport 700/1000, separate from motor and speed controller. The original drawing names PL-PMP-240250, a mechanically coupled head. This MAG5 magnetic-drive head requires confirmation of the installed motor/coupling, drive arrangement, ports and approved conversion with Spectra; it is not proven to be a bare-head drop-in for the 2005 assembly.

Existing fitment requirements

  • MAG5 magnetic-drive feed pump configuration only. Excludes older direct-drive pumps.

Manufacturer / research reference ↗

View part & current price
SO-FHS-10H

High Pressure Filter Housing O-ring

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Identification requirements & source

Black high-pressure 10H housing family for the pressurized fine-filter stage: FT-FTH-10H uses SO-FHS-10H and FT-FHW-10H, with the 10HSS stainless wrench option. The model spares list names SO-FHS-10H. Match the actual black bowl and lid; a clear three-piece seal is a different family.

Existing fitment requirements

  • For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.

Manual, page 1 ↗

View part & current price
SO-HPP-PT20

20% Piston O-Ring

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. The 20% piston is Delrin with replaceable piston seal and bushing; it differs from the one-piece 7% / 10% piston. Compare the complete 20PTA assembly with the loose PT20 piston and current seal/bushing callouts before duplicating pieces. The May 2024 manual uses separately named seal/bushing parts; confirm the historical SO-HPP-PT20 O-ring scope with Spectra.

Identification requirements & source

The 20% piston is Delrin with replaceable piston seal and bushing; it differs from the one-piece 7% / 10% piston. Compare the complete 20PTA assembly with the loose PT20 piston and current seal/bushing callouts before duplicating pieces. The May 2024 manual uses separately named seal/bushing parts; confirm the historical SO-HPP-PT20 O-ring scope with Spectra.

Existing fitment requirements

  • Installed 20% Clark pump matching the May 2024 rebuild-manual design. component in the cited pump assembly; identify actual ratio and revision after any retrofit. Excludes rare 15% pumps and unverified older revisions.

Manual, page 96 ↗

View part & current price
KIT-HP-20UD

20% Clark Pump Upgrade Kit Dist.

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Identification requirements & source

Distributor rebuild kit for an identified 20% Newport 700/1000 Clark Pump. Current manufacturer contents exclude spacer rings and top-end spool pistons; tools and instructions are not supplied. Compare kit map and present contents before adding individual pieces.

Existing fitment requirements

  • Installed 20% Clark Pump; select full rebuild or offshore kit according to the service required. Requires the installed 20% Clark Pump and matching revision. Verify the pump identification after any retrofit; system name alone is insufficient. Requires the installed 20% Clark Pump and matching revision. Verify the pump identification after any retrofit; system name alone is insufficient.

Manufacturer / research reference ↗

View part & current price
KIT-MNF-BURDV12

Burkert diversion-valve conversion kit

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. Current Burkert product-water diversion conversion for the charted eligible legacy 12V / 24V route. Confirm installed body, manifold, wiring, output and required fittings with Spectra. It does not replace the freshwater-flush valve or main intake manifold.

Identification requirements & source

Current Burkert product-water diversion conversion for the charted eligible legacy 12V / 24V route. Confirm installed body, manifold, wiring, output and required fittings with Spectra. It does not replace the freshwater-flush valve or main intake manifold.

Existing fitment requirements

  • Replace the complete legacy ECI/Alcon diversion valve with the manufacturer conversion assembly; compatible with 12V and 24V systems. Conversion kit retains the existing flow sensor and salinity probe; these are not included. Preserve the required Ventura reducer and use the kit wiring instructions; the solenoid rating is a component rating, not the vessel supply voltage. Match installed valve function, voltage and body/interface. A model connection does not make all valve revisions interchangeable. Match installed valve function, voltage and body/interface. A model connection does not make all valve revisions interchangeable.

Manual, page 1 ↗

View part & current price
KIT-MPC-5KUPG12

Mpc-5000 Upgrade Kit 12V

24V DC / 110V AC / 220V AC layout references · 12V DC controls — identify separately · Current manufacturer reference

Confirm with Spectra before ordering. MPC-3000 to MPC-5000 conversion for confirmed 12V DC controller supply. On AC watermakers, identify the separate DC controls supply; never choose this kit using the 110/220V motor input alone. The original 24V DC arrangement uses the 24V route. Retains the existing MPC display and requires wiring re-termination, programming and actual Newport motor/controller verification with Spectra. Includes A40 board, SP4, Rotoflo and fittings; the 24V kit also includes a 12V flush solenoid. Do not duplicate included parts.

Identification requirements & source

MPC-3000 to MPC-5000 conversion for confirmed 12V DC controller supply. On AC watermakers, identify the separate DC controls supply; never choose this kit using the 110/220V motor input alone. The original 24V DC arrangement uses the 24V route. Retains the existing MPC display and requires wiring re-termination, programming and actual Newport motor/controller verification with Spectra. Includes A40 board, SP4, Rotoflo and fittings; the 24V kit also includes a 12V flush solenoid. Do not duplicate included parts.

Existing fitment requirements

  • Upgrade eligibility only: installed MPC-3000 controls and 12V system required. Confirm controller generation and voltage before ordering; model name or purchase date alone is insufficient. Requires wiring re-termination and system-specific programming. Catalina installations also require the relay changes in the upgrade manual. Not a conversion for analog Deluxe, Connect, Santa Cruz, Gulfstream or 380C systems.

Manufacturer / research reference ↗

View part & current price
KIT-MPC-5KUPG24

Mpc-5000 Upgrade Kit 24V

24V DC / 110V AC / 220V AC layout references · 24V DC controls — identify separately · Current manufacturer reference

Confirm with Spectra before ordering. MPC-3000 to MPC-5000 conversion for confirmed 24V DC controller supply. On AC watermakers, identify the separate DC controls supply; never choose this kit using the 110/220V motor input alone. The original 24V DC arrangement uses the 24V route. Retains the existing MPC display and requires wiring re-termination, programming and actual Newport motor/controller verification with Spectra. Includes A40 board, SP4, Rotoflo and fittings; the 24V kit also includes a 12V flush solenoid. Do not duplicate included parts.

Identification requirements & source

MPC-3000 to MPC-5000 conversion for confirmed 24V DC controller supply. On AC watermakers, identify the separate DC controls supply; never choose this kit using the 110/220V motor input alone. The original 24V DC arrangement uses the 24V route. Retains the existing MPC display and requires wiring re-termination, programming and actual Newport motor/controller verification with Spectra. Includes A40 board, SP4, Rotoflo and fittings; the 24V kit also includes a 12V flush solenoid. Do not duplicate included parts.

Existing fitment requirements

  • Upgrade eligibility only: installed MPC-3000 controls and 24V system required. Confirm controller generation and voltage before ordering; model name or purchase date alone is insufficient. Requires wiring re-termination and system-specific programming. Catalina installations also require the relay changes in the upgrade manual. Not a conversion for analog Deluxe, Connect, Santa Cruz, Gulfstream or 380C systems.

Manufacturer / research reference ↗

View part & current price
KIT-SLN-ECISPO1

Eci To Sparton 1-W Valve Kit 12V

24V DC / 110V AC / 220V AC layout references · Current manufacturer reference

Confirm with Spectra before ordering. 12V ECI/Alcon freshwater-flush coil conversion retaining the old valve body. Confirm actual coil output, retained body and MPC revision with Spectra. Original 24V system supply does not prove the installed flush output remains 24V after an A40 conversion.

Identification requirements & source

12V ECI/Alcon freshwater-flush coil conversion retaining the old valve body. Confirm actual coil output, retained body and MPC revision with Spectra. Original 24V system supply does not prove the installed flush output remains 24V after an A40 conversion.

Existing fitment requirements

  • Legacy ECI/Alcon 12V freshwater-flush solenoid; retain its existing valve body. If replacing the body too, manufacturer specifies PL-SLN-1/4O12SV. Match installed valve function, voltage and body/interface. A model connection does not make all valve revisions interchangeable. Match installed valve function, voltage and body/interface. A model connection does not make all valve revisions interchangeable.

Manual, page 1 ↗

View part & current price
Additional candidates requiring confirmation

Confirm these specific links with Spectra before ordering. The source does not prove direct interchangeability, exact current revision or complete conversion contents.

EL-MPC-SP4N

SP4N probe, 3-foot cable — confirm connection

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Shorter three-foot SP4N candidate. The manufacturer compatibility table names SP4 without establishing this suffix and connector. Confirm chip interface, connector and actual reach with Spectra before using this link.

Identification requirements & source

Shorter three-foot SP4N candidate. The manufacturer compatibility table names SP4 without establishing this suffix and connector. Confirm chip interface, connector and actual reach with Spectra before using this link.

Manufacturer / research reference ↗

View part & current price
PL-SLN-1/4O12SP

1/4 2-Way Solenoid 12V Spar W/O Vbd

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Newport Spartan 12V freshwater-flush solenoid without valve body, charted for later production since 2016. It is not an established direct substitution for every original intake/flush module. Confirm installed valve body, output, port and connector with Spectra.

Identification requirements & source

Newport Spartan 12V freshwater-flush solenoid without valve body, charted for later production since 2016. It is not an established direct substitution for every original intake/flush module. Confirm installed valve body, output, port and connector with Spectra.

Manual, page 1 ↗

View part & current price
PL-SLN-1/4O12SV

12V freshwater-flush solenoid with valve body

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Spartan 12V freshwater-flush assembly including valve body. Confirm the original Newport module, mounting, ports, control output and any adaptation with Spectra. It is separate from the product diversion valve.

Identification requirements & source

Spartan 12V freshwater-flush assembly including valve body. Confirm the original Newport module, mounting, ports, control output and any adaptation with Spectra. It is separate from the product diversion valve.

Manual, page 1 ↗

View part & current price
FT-FHW-3PCS

3-Pcs Std 10" Filter Housing Wrench

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Later clear three-piece housing family: FT-FTH-10L3PCS uses SO-FHS-3PCS10 and FT-FHW-3PCS. It is a changed-hardware reference, not an established direct substitution for every original 10L intake/flush bowl. Confirm the actual housing and pressure rating with Spectra.

Identification requirements & source

Later clear three-piece housing family: FT-FTH-10L3PCS uses SO-FHS-3PCS10 and FT-FHW-3PCS. It is a changed-hardware reference, not an established direct substitution for every original 10L intake/flush bowl. Confirm the actual housing and pressure rating with Spectra.

Manual, page 1 ↗

View part & current price
FT-FTH-10L3PCS

10" Low Press. Filter Housing 3 Pcs

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Later clear three-piece housing family: FT-FTH-10L3PCS uses SO-FHS-3PCS10 and FT-FHW-3PCS. It is a changed-hardware reference, not an established direct substitution for every original 10L intake/flush bowl. Confirm the actual housing and pressure rating with Spectra.

Identification requirements & source

Later clear three-piece housing family: FT-FTH-10L3PCS uses SO-FHS-3PCS10 and FT-FHW-3PCS. It is a changed-hardware reference, not an established direct substitution for every original 10L intake/flush bowl. Confirm the actual housing and pressure rating with Spectra.

Manual, page 1 ↗

View part & current price
SO-FHS-3PCS10

3-Piece Filter Housing 0-Ring

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Later clear three-piece housing family: FT-FTH-10L3PCS uses SO-FHS-3PCS10 and FT-FHW-3PCS. It is a changed-hardware reference, not an established direct substitution for every original 10L intake/flush bowl. Confirm the actual housing and pressure rating with Spectra.

Identification requirements & source

Later clear three-piece housing family: FT-FTH-10L3PCS uses SO-FHS-3PCS10 and FT-FHW-3PCS. It is a changed-hardware reference, not an established direct substitution for every original 10L intake/flush bowl. Confirm the actual housing and pressure rating with Spectra.

Manual, page 1 ↗

View part & current price
KIT-MB-40F

Long membrane kit, 2.5 × 40 inches

24V DC / 110V AC / 220V AC layout references · confirmed 2.5 × 40-inch element; system count requires confirmation · Installed-hardware review

Confirm with Spectra before ordering. One kit supplies one 2.5 × 40-inch seawater element and replacement seals. The original shared manual pictures three vessels without an explicit model-specific element-size/count table. Later Newport 1000 arrangements use 3 long elements, but that is not proof of this older installation. Confirm actual size, count and end-cap/Z-Brane revision with Spectra. No whole-system order quantity is chosen automatically.

Identification requirements & source

One kit supplies one 2.5 × 40-inch seawater element and replacement seals. The original shared manual pictures three vessels without an explicit model-specific element-size/count table. Later Newport 1000 arrangements use 3 long elements, but that is not proof of this older installation. Confirm actual size, count and end-cap/Z-Brane revision with Spectra. No whole-system order quantity is chosen automatically.

Manufacturer / research reference ↗

View part & current price
KIT-OFFSH1

Offshore Kit For 20%

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Current catalog offshore service kit specifically labeled for 20% pumps. The original spares list says KIT-OFFSH generically, but the present KIT-OFFSH listing is for 7% / 10%. Confirm current 20% offshore contents with Spectra before using this route or duplicating loose seals and cleaners.

Identification requirements & source

Current catalog offshore service kit specifically labeled for 20% pumps. The original spares list says KIT-OFFSH generically, but the present KIT-OFFSH listing is for 7% / 10%. Confirm current 20% offshore contents with Spectra before using this route or duplicating loose seals and cleaners.

Existing fitment requirements

  • Installed 20% Clark Pump; select full rebuild or offshore kit according to the service required.
  • Corrected against the newer Clark guide: installed 20% Newport 700/1000 pump requires KIT-OFFSH1.

Manual, page 46 ↗

View part & current price
KIT-PV-25EP1

2.5" Pressure Vessel End Plug Replacement Kit

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Vessel hardware is separate from the membrane element. The original drawing includes FT-PV-ZEP / FT-PV-ZEPB Z-Brane end-cap hardware; later diagrams name KIT-PV-25EP1. Confirm the actual end-cap, ring and electrode arrangement with Spectra before assuming the later kit replaces an original assembly. Do not disturb Z-Brane high-voltage wiring.

Identification requirements & source

Vessel hardware is separate from the membrane element. The original drawing includes FT-PV-ZEP / FT-PV-ZEPB Z-Brane end-cap hardware; later diagrams name KIT-PV-25EP1. Confirm the actual end-cap, ring and electrode arrangement with Spectra before assuming the later kit replaces an original assembly. Do not disturb Z-Brane high-voltage wiring.

Manual, page 30 ↗

View part & current price
PL-SLN-1/4D12SP

1/4 Diversion Valve 12V Spartan

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 12V Spartan product-water diversion candidate. Confirm actual body, coil output, manifold and connector with Spectra. Original page 65 lists an older D12VB suffix, not this later SP suffix.

Identification requirements & source

12V Spartan product-water diversion candidate. Confirm actual body, coil output, manifold and connector with Spectra. Original page 65 lists an older D12VB suffix, not this later SP suffix.

Manual, page 1 ↗

View part & current price
PL-SLN-1/4D24SP

1/4 Diversion Valve 24V Spart

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 24V Spartan product-water diversion candidate. Confirm actual body, coil output, manifold and connector with Spectra; a 24V boat supply does not settle control outputs after a retrofit.

Identification requirements & source

24V Spartan product-water diversion candidate. Confirm actual body, coil output, manifold and connector with Spectra; a 24V boat supply does not settle control outputs after a retrofit.

Manual, page 1 ↗

View part & current price
PL-SLN-1/4O24

1/4" 1-Way Solinoid Valve 24V

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 24V freshwater-flush candidate. Match the actual controller output and valve body with Spectra. The modern 24V MPC conversion includes a 12V flush solenoid because A40 steps down flush control, so a boat supply label is not sufficient.

Identification requirements & source

24V freshwater-flush candidate. Match the actual controller output and valve body with Spectra. The modern 24V MPC conversion includes a 12V flush solenoid because A40 steps down flush control, so a boat supply label is not sufficient.

Manual, page 1 ↗

View part & current price
SUB-NP-DVMSP

Diversion Valve Manifold Sparton

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Later Spartan product diversion manifold candidate. Confirm actual valve body, port arrangement and required fittings with Spectra; it is not an established automatic replacement for the original DVM.

Identification requirements & source

Later Spartan product diversion manifold candidate. Confirm actual valve body, port arrangement and required fittings with Spectra; it is not an established automatic replacement for the original DVM.

Manual, page 1 ↗

View part & current price
EL-MTR-1D24

Later one-HP 24V motor — confirm conversion

24V DC feed-power candidate · Installed-hardware review

Confirm with Spectra before ordering. Later one-HP 24V motor candidate, not the original EL-MTR-3/4D24 identified in the September 2005 manual. The original three-quarter-HP DC motor has no exact listing in this catalog. Confirm an approved motor/coupling/controller conversion with Spectra; higher horsepower alone does not establish interchangeability. The Newport 400 half-HP conversion bulletin does not establish this route.

Identification requirements & source

Later one-HP 24V motor candidate, not the original EL-MTR-3/4D24 identified in the September 2005 manual. The original three-quarter-HP DC motor has no exact listing in this catalog. Confirm an approved motor/coupling/controller conversion with Spectra; higher horsepower alone does not establish interchangeability. The Newport 400 half-HP conversion bulletin does not establish this route.

Manual, page 63 ↗

View part & current price
KIT-HP-20R

20% Clark Pump Reman. (Core $2,200)

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 20% remanufactured-pump route, separate from a loose-parts rebuild kit. Confirm installed pump revision, exchange/core conditions and included fittings with Spectra. Historical catalog core wording is not a live checkout price or deposit claim.

Identification requirements & source

20% remanufactured-pump route, separate from a loose-parts rebuild kit. Confirm installed pump revision, exchange/core conditions and included fittings with Spectra. Historical catalog core wording is not a live checkout price or deposit claim.

Existing fitment requirements

  • Factory service for an installed 20% Clark Pump; confirm current RMA, freight and exchange deposit/return terms.

Manual, page 46 ↗

View part & current price
KIT-HP-20U

20% Clark Pump Upgrade (Org. Cust. Pmp)

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Factory upgrade of the original customer-owned 20% pump, separate from an exchange pump or distributor rebuild kit. Confirm service scope, actual pump eligibility and handling with Spectra before using this link.

Identification requirements & source

Factory upgrade of the original customer-owned 20% pump, separate from an exchange pump or distributor rebuild kit. Confirm service scope, actual pump eligibility and handling with Spectra before using this link.

Existing fitment requirements

  • Factory service for an installed 20% Clark Pump; confirm current RMA, freight and repair arrangements.

Manual, page 46 ↗

View part & current price
KIT-HP20

High Press. Pump 20% For N.P. Assem

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 20% high-pressure pump assembly for Newport, named in the later Parts ID diagram. Confirm actual module mounting, fittings and current assembly contents with Spectra before replacing an original 2005 unit.

Identification requirements & source

20% high-pressure pump assembly for Newport, named in the later Parts ID diagram. Confirm actual module mounting, fittings and current assembly contents with Spectra before replacing an original 2005 unit.

Manual, page 30 ↗

View part & current price
KIT-PMP-240MRF

240 Mag Pump- Remanufactured (C250)

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Remanufactured 240 MAG package candidate. Confirm head revision, supplied components, core terms and compatible motor/coupling with Spectra. A package listing is neither the original mechanical-drive head nor an automatically complete motor/controller conversion.

Identification requirements & source

Remanufactured 240 MAG package candidate. Confirm head revision, supplied components, core terms and compatible motor/coupling with Spectra. A package listing is neither the original mechanical-drive head nor an automatically complete motor/controller conversion.

Manual, page 63 ↗

View part & current price
PL-PMP-240250E

Mechanical-drive 240/250 head — confirm E suffix

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Current catalog mechanical-drive 240/250 stainless head candidate. The original manual names PL-PMP-240250 without the E suffix. Confirm suffix equivalence, pressure rating, shaft, coupling and connections with Spectra before ordering. It is distinct from the current MAG5 magnetic-drive head.

Identification requirements & source

Current catalog mechanical-drive 240/250 stainless head candidate. The original manual names PL-PMP-240250 without the E suffix. Confirm suffix equivalence, pressure rating, shaft, coupling and connections with Spectra before ordering. It is distinct from the current MAG5 magnetic-drive head.

Existing fitment requirements

  • Older direct-drive Newport 700/1000 pump configuration; not MAG5. Match shaft and drive hardware.

Manual, page 63 ↗

View part & current price
KIT-HP-S&OH

Seals & O-Rings Kit 20%

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. 20% seal-and-O-ring service kit. It differs from the 7% / 10% S&O kit and the broader distributor rebuild kit. Match the actual pump ratio and current contents; it does not imply supply of every hard internal part.

Identification requirements & source

20% seal-and-O-ring service kit. It differs from the 7% / 10% S&O kit and the broader distributor rebuild kit. Match the actual pump ratio and current contents; it does not imply supply of every hard internal part.

Existing fitment requirements

  • Select the installed 20% Clark Pump. The factory bulletin documents 20%; it does not establish 15% compatibility.

Manual, page 46 ↗

View part & current price
SO-FHS-LP10

Filter Housing Seal

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. The current matrix puts SO-FHS-LP10 under the discontinued standard FT-FTH-10 housing, not under the separate FT-FTH-10L column. Do not order it for an original clear 10L bowl solely from this model selection; confirm actual seal groove and housing identification with Spectra.

Identification requirements & source

The current matrix puts SO-FHS-LP10 under the discontinued standard FT-FTH-10 housing, not under the separate FT-FTH-10L column. Do not order it for an original clear 10L bowl solely from this model selection; confirm actual seal groove and housing identification with Spectra.

Manual, page 1 ↗

View part & current price
ZION-AUTO

Z-Ion For Auto System

24V DC / 110V AC / 220V AC layout references · Installed-hardware review

Confirm with Spectra before ordering. Retained identification candidate for the original MPC model. The present documentation does not establish exact current revision, package contents or direct replacement equivalence. Give Spectra the original part code, assembly location and installed label before selecting this link.

Identification requirements & source

Retained identification candidate for the original MPC model. The present documentation does not establish exact current revision, package contents or direct replacement equivalence. Give Spectra the original part code, assembly location and installed label before selecting this link.

Existing fitment requirements

  • Optional Z-Ion control type for MPC, Connect and Remote Manual. Confirm installed generation, suitable accessory power and plumbing before installation.

Manufacturer / research reference ↗

View part & current price

KEEP THE ORIGINAL AND CURRENT REFERENCES TOGETHER

Manuals and manufacturer resources