Overview
Overview
PL-VLV-3W3/4 is the 3/4-inch three-way valve shown at the front of the Newport 400 MkII service and boost module. Spectra also identifies this valve in the Ventura feed-module plumbing.
The valve routes the module’s plumbing through its selected connection. The complete service/boost module, adjoining elbows and hose fittings are separate listings; the valve part number alone does not describe that complete assembly.
Specifications & Contents
Specifications & Contents
| Part number | PL-VLV-3W3/4 |
|---|---|
| Nominal size | 3/4 inch |
| Form | Three-way valve |
| Documented locations | Newport 400 MkII service/boost module; Ventura feed module |
Fits My System
Fits My System
Match the connection sizes and the installation conditions in the cited drawing. A documented example does not establish universal fit or a pressure rating.
Select your configuration to see its requirements, or open the complete reference below.
All documented configurations and requirements
Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.
Documented configurations
- Cape Horn Extreme 330 · Deluxe · 12 VDC · Compact / short membranes · CH-330-12S
- Cape Horn Extreme 330 · Deluxe · 12 VDC · Standard / long membranes · CH-330-12
- Cape Horn Extreme 330 · Deluxe · 24 VDC · Compact / short membranes · CH-330-24S
- Cape Horn Extreme 330 · Deluxe · 24 VDC · Standard / long membranes · CH-330-24
Cape Horn analog feed A/manual sample module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Cape Horn Extreme 330R · Remote · 12 VDC · Compact / short membranes · CH-330R-12S
- Cape Horn Extreme 330R · Remote · 12 VDC · Standard / long membranes · CH-330R-12
- Cape Horn Extreme 330R · Remote · 24 VDC · Compact / short membranes · CH-330R-24S
- Cape Horn Extreme 330R · Remote · 24 VDC · Standard / long membranes · CH-330R-24
Cape Horn Remote feed A/sample module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Catalina 300 Mk II-Z · MPC 5000 · Match installed voltage and hardware
Catalina 300 Mk II-Z feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Catalina 300 · MPC 5000 · Match installed voltage and hardware
Catalina 300 MPC feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Farallon 1800C · Connect · 220 VAC · Standard / long membranes · FL-1800C-220
- Farallon 2800C · Connect · 220 VAC · Standard / long membranes · FL-2800C-220
Farallon Connect feed/filter/boost/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Monterey 1000 · MPC 3000 · Match installed voltage and hardware
Monterey historical plumbing chapter. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Historical pictured module only. Pump internals and electrical variants are not inherited.
Documented configurations
- Newport 1000 · MPC 3000 · Match installed voltage and hardware
- Newport 700 · MPC 3000 · Match installed voltage and hardware
Newport 700/1000 MPC 3000 feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Newport 400 Mk II · MPC 5000 · Match installed voltage and hardware
Newport 400 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Newport 400 · MPC 5000 · Match installed voltage and hardware
Newport 400 Mk I MAG feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Ventura 150 MPC · Match installed voltage and hardware
- Ventura 200T MPC · Match installed voltage and hardware
Ventura MPC feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Ventura 150C · Connect · 12 VDC · Standard · VT-150C-12V
- Ventura 150C · Connect · 24 VDC · Standard · VT-150C-24V
- Ventura 200C · Connect · 12 VDC · Standard · VT-200C-12V
- Ventura 200C · Connect · 24 VDC · Standard · VT-200C-24V
Ventura Connect filter/feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Ventura 150D · Deluxe · 12 VDC · Standard · VT-150-D-12V
- Ventura 150D · Deluxe · 24 VDC · Standard · VT-150-D-24V
- Ventura 200T · Deluxe · 12 VDC · Standard · VT-200-T-12
- Ventura 200T · Deluxe · 24 VDC · Standard · VT-200-T-24
Ventura Deluxe feed and manual flush modules. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Ventura 150R · Remote · 12 VDC · Standard · VT-150R-12
- Ventura 150R · Remote · 24 VDC · Standard · VT-150R-24
- Ventura 200R-T · Remote · 12 VDC · Standard · VT-200R-T-12
- Ventura 200R-T · Remote · 24 VDC · Standard · VT-200R-T-24
Ventura Remote feed and flush modules. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.