SPECTRA OWNER GUIDE

Newport 1000C Connect parts & owner guide

Follow the 1000C water path, identify filters and three 40-inch membranes, choose your supply voltage and compare 20% Clark Pump components with the original exploded drawings.

24V / 48V DC · 110V / 220V AC · Spectra Connect

Match your system supply

Read the installed system and motor labels, especially after a retrofit.

Showing parts common to all four original configurations. Select the system supply to see electrical parts.

CHECK THE SYSTEM

Newport 1000C or 700C?

Four electrical supplies

24V and 48V DC systems use different motors and control paths. The AC models have 110V or 220V system input, but the manufacturer drawing identifies the same 240VAC three-phase feed motor downstream of speed controls. Read both labels before replacing electrical components.

24V module ↗ · 48V module ↗ · AC modules ↗

MATCH EACH FILTER

Seawater stages and freshwater flush

The seawater prefilters are nominal 10 × 2.5 inches: 20 micron upstream and 5 micron downstream. The carbon cartridge treats the separate freshwater flush; matching cartridge size does not make these stages interchangeable.

PathCartridgeHousing
Seawater, first20 micron FT-FTC-20
10 × 2.5 in nominal
Three-piece housing
Housing seal
Seawater, second5 micron FT-FTC-5
10 × 2.5 in nominal
Separate three-piece housing
Freshwater flushCarbon FT-FTC-CC
10 × 2.5 in nominal
Separate flush housing; Z-Ion bowl may differ

The sea strainer is ahead of the booster pump. The standard six-inch screen differs from the plastic strainer screen labeled FT-STN-6SP. Match the body and seal before ordering.

Filter sizes ↗ · Strainer drawing ↗ · Dual prefilter drawing ↗ · Flush drawing ↗

FOLLOW THE WATER

Explore the four modules

These are Spectra’s 700C/1000C parts drawings. The upper high-pressure drawing shows the 1000C three-vessel layout. Choose a module to compare the installed assembly.

Sea strainer & booster

The six-inch strainer and 8–24V booster pump are ahead of the feed module. The 48V system uses a separate voltage-conversion path; do not wire an 8–24V pump directly to 48V.

Original parts drawing ↗

Spectra Newport 1000C manufacturer parts drawing, page 94: Sea strainer & booster

THE 1000C DIFFERENCE

Three vessels, one 20% pump

INSIDE THE 20% PUMP

Explore the actual 1000C exploded drawings

The prior guide’s 3D pump reconstruction supports 7% and 10% hardware. It cannot accurately represent this 20% pump, so these manufacturer drawings are the identification view. Compare the installed pump ratio and revision before ordering internal components.

Outside

The 20% center block joins the two cylinder assemblies. The drawing labels A and B valve end blocks as different parts.

Center block · A end block · B end block

Full-size drawing, page 102 ↗

Newport 1000C 20 percent Clark Pump Outside exploded drawing, page 102
Full rebuild or individual seals?

20% distributor rebuild kit and 20% seal and O-ring kit have different scopes. Check the kit contents and installed pump before ordering overlapping parts. The manufacturer drawings are an identification aid, not a disassembly procedure.

SELECT THE INPUT SUPPLY

Motors, breakers and controllers

System inputDocumented componentsWhat to check
24V DC24V 1 HP motor · 30A breaker · PWM assemblyMotor label and exact PWM revision. Newport manual, page 97 ↗
48V DC48V 1 HP motor EL-MTR-1D48 · 48-to-24V converter EL-PS-720W48/24 · 15A breakerMotor and converter appear in the drawing but are not in this store catalog. Newport manual, page 98 ↗
110V AC240VAC three-phase feed motor · 15A breakerThe speed controller drives the motor; incoming 110V is not the motor nameplate. Newport manual, page 99 ↗
220V AC240VAC three-phase feed motor · 10A breakerMatch controller input and motor nameplate. Newport manual, page 99 ↗

The existing product URL for EL-BRK-30ADP still contains an old “10a” slug, but its SKU and 2025 24V drawing identify a 30A breaker. Confirm the actual breaker label before purchase. 30A drawing ↗

CARE & BUYING CHOICES

Choose only what the task needs

Filters and storage

Replace dirty seawater prefilters as the manual directs. Change the flush carbon filter at least every six months. SC-1 preserves a stored system; SC-2 and SC-3 address different diagnosed membrane fouling.

Maintenance ↗ · Cleaning ↗

ANSWERS FOR OWNERS

Frequently confused choices

Does the Newport 1000C use one or three membrane kits?

The original Newport 1000C has three 2.5 × 40-inch membrane elements. One KIT-MB-40F replaces one; three kits replace all three. Count installed vessels if the system has been modified.

Are the 1000C and 700C pressure modules identical?

Both have a documented 20% pump, but the 1000C has a third membrane vessel, different pressure-module layout and extra mounting hardware. Match the installed tubing and vessel arrangement before ordering.

Which filter goes first?

Seawater enters the 20-micron FT-FTC-20 prefilter, then the 5-micron FT-FTC-5. The carbon FT-FTC-CC is in the separate freshwater-flush circuit.

Why does a 110V Newport list a 240VAC three-phase motor?

Spectra labels the installed motor EL-MTR-3/4AC220 in both AC module drawings. The motor-speed controller connects system input to the motor. Check the installed motor and controller labels.

Does the 48V system have a 48V booster pump?

The booster-pump drawing labels an 8–24V part. The 48V module also contains a 48-to-24V converter; do not connect the booster directly to the 48V supply.

Can the 400C 3D Clark Pump model identify 1000C internal parts?

No. That reconstruction supports 7% and 10% geometry. Use the original 20% Newport exploded drawings and installed part labels for this system.

CATALOG REFERENCE

Documented parts by voltage

Choose the system input above to narrow these parts. The list includes small fittings and service items; identification does not set the order quantity. Confirm installed revisions and package contents on the linked product page.

114 reviewed references across the four original supplies.

PL-SLN-1/4O12SP

1/4 2-Way Solenoid 12V Spar W/O Vbd

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 96 ↗

View part & current price
EL-MPC-SP4

Salinity Probe 4Th Generation 15'

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identify the installed controller and follow the Controller & Probe Replacement section on this page. Match cable reach and connections; this configuration listing alone is not an unconditional replacement recommendation.

Manufacturer reference ↗

View part & current price
KIT-SC-RMPNL

Spectra Connect Remote Control Disp.4.3" W/Cbl.

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Connect remote display supplied with 100 feet of CAT-5 cable; display-only SKU has different contents.

Newport manual, page 101 ↗

View part & current price
FT-FTH-10L3PCS

10" Low Press. Filter Housing 3 Pcs

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Three-piece low-pressure housing for the seawater cartridges; the freshwater-flush module also uses a housing, with Z-Ion bowl differences.

Newport manual, page 95 ↗

View part & current price
KIT-MB-40F

2.5" X 40" Membrane Kit

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

One 2.5 × 40-inch element per kit. Original Newport 1000C has three vessels, so replacing all elements requires three kits. Vessel end plugs and rings are separate.

Newport manual, page 92 ↗

View part & current price
PL-HBS-1/2X3/4

1/2" Npt X 3/4" Hose Barb St Nylon

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 96 ↗

View part & current price
PL-FRG-1/2MF1.5

1/2" Npt-Fpt Flow Reg 1.5G 20-80Psi

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 100 ↗

View part & current price
PL-SLN-1/4D12M

1/4" Diversion Valve 12 V (Mnf)

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Requires the matching Burkert manifold and 12V solenoid specification. Confirm the installed assembly and voltage.

Manufacturer reference ↗

View part & current price
PL-NLT-1/4LP

1/4" Low Pressure Tube (Product) (Per Foot)

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 101 ↗

View part & current price
PL-HBS-1/4X1/2

1/4" Npt X 1/2" Hose Barb St. Nylon

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 100 ↗

View part & current price
PL-MTS-1/4X1/4J

1/4"Npt X 1/4" Tube Fitting Jg

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 93 ↗

View part & current price
PL-MTE-1/4X1/4J

1/4"Npt X 1/4" Tube Fitting Nylon El. Jg.

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 93 ↗

View part & current price
PL-FTE-1/8X1/4P

1/8" Female NPT x 1/4" Tube Elbow Fitting

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 92 ↗

View part & current price
PL-HBE-3/4X3/4

3/4" Npt X 3/4" Hose Barb Ell Nylon

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 95 ↗

View part & current price
PL-HBS-3/4X3/4

3/4" Npt X 3/4" Hose Barb St. Nylon

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 94 ↗

View part & current price
PL-BSH-3/4X1/4N

3/4" X 1/4" Hex Bushing Reducer Nyl

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 100 ↗

View part & current price
PL-MFF-3/4X3/4

3/4"Mpt X 3/4" Fpt Elbow Fitt. Nylon

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 100 ↗

View part & current price
PL-NLT-3/8LP

3/8" Low Pressure Tube (Product) (Per Foot)

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 101 ↗

View part & current price
PL-HBA-3/8TX1/2

3/8" T Stem X 1/2" Hose Barb Adapter

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 101 ↗

View part & current price
PL-MTS-3/8X1/2SL

316L Stainless Straight Fitting, 3/8 in NPT x 1/2 in Tube

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 92 ↗

View part & current price
PL-HBE-7/8SX3/4

7/8"-14S X 3/4" Hose Barb El Ss.

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 96 ↗

View part & current price
HP‐CYL‐CCA

Cylinder Assembly (G‐10 BASE)

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Manufacturer reference ↗

View part & current price
PL-MTE-3/8X3/8J

John Guest Elbow, 3/8 in NPT x 3/8 in Tube

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 93 ↗

View part & current price
SUB-NP-MK2-ILHA

Np Mk-Ii 700/1K Inlet Hose Assembly

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Documented 10-foot Newport 700/1000 inlet hose assembly; preserve its end connections. The historical retrofit concerns Mk II units with rigid feed-to-Clark tubing, especially pre-October 2009 units; it does not establish a Mk I retrofit.

Newport manual, page 101 ↗

View part & current price
PL-FHB-1/2X3/4E

Nylon Hose Barb Elbow, 1/2 in FPT x 3/4 in Barb

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 94 ↗

View part & current price
PL-CKV-1M3/4FWS

Spring Check Valve, 1 in MPT x 3/4 in FPT

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 94 ↗

View part & current price
EL-MTR-3/4AC220

3/4 Hp, 240 Vac, 3 Phase, 56C Motor

110V AC / 220V AC

Fitment and source

Three-phase 240VAC motor appears in both 110V and 220V input systems through their speed-control modules. Match motor label and controller.

Newport manual, page 99 ↗

View part & current price
EL-FP-BPLDC824

300-1K Boost Pump 12/24Vdc 1/2"Npt

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

8–24V booster pump in the sea-strainer module. Do not connect this part directly to the 48V input supply.

Newport manual, page 94 ↗

View part & current price
SUB-CT-Z-HPILHA

Clark Pump Brine Pigtail

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Complete Clark brine pigtail at the documented discharge connection. Match the pictured connector arrangement; this is not the feed-pump high-pressure inlet hose. The CT prefix does not restrict it to Catalina.

Newport manual, page 93 ↗

View part & current price
PL-TB-HPTPVUL1K

Hp Pump To Pv Ss Tube Long1K(Upper)

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 92 ↗

View part & current price
PL-TB-HPTPVLL

Hp Pump To Pv Ss. Tube Long (Lower)

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 92 ↗

View part & current price
EL-FP-BPLDC824IM

Laing Booster Pump Impeller

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Replacement impeller for an installed EL-FP-BPLDC824 Laing boost pump. Identify the actual pump; not a generic impeller for all boost pumps.

Newport manual, page 94 ↗

View part & current price
KIT-NP-M2Z-SBPH

Strainer-Dual Boost Pump Module

110V AC / 220V AC / 24V DC / 48V DC

Fitment and source

Identified in the reviewed Newport 1000C parts mapping. Compare SKU and installed hardware before replacement.

Newport manual, page 94 ↗

View part & current price

REVISION REVIEW

Conditional links

Parts that need an installed-hardware check

These listings are useful for identification, but revision, package or catalog naming still needs confirmation. Give Spectra the system label and component label before ordering.

HP-CYL-7/8R

Piston Rod (10%)

Confirm with Spectra before ordering.

The catalog labels this rod 10%, while the 20% Newport center-block page includes a photo bearing this SKU. Confirm the installed 20% rod dimensions and revision with Spectra before ordering.

Inspect listing
SO-HPP-PR10

Piston Rod Seal

Confirm with Spectra before ordering.

The catalog labels this a 10% rod seal, while the 20% Newport drawing refers to multiple rod-lip seal sizes. Confirm the installed seal size with Spectra before ordering.

Inspect listing
SUB-NP-MK2-INT

Newport Manifold Eci Pre Z-Ion

Confirm with Spectra before ordering.

Original ECI intake manifold. The manual drawing identifies this version; compare installed generation, valves and connectors before replacement.

Inspect listing
SUB-NP-MK2-INTZ

Newport Mk-Ii Intake Manifold Z-Ion

Confirm with Spectra before ordering.

Z-Ion intake manifold revision. Confirm the installed Z-Ion and manifold generation.

Inspect listing
SUB-NP-MK2-INEZ

Newport Intake Manifold Eci Z-Ion

Confirm with Spectra before ordering.

ECI Z-Ion intake variant; the current drawing uses a different intake identifier. Confirm revision and complete assembly.

Inspect listing
KIT-BCK-B

Cruise Kit B

Confirm with Spectra before ordering.

Cruise Kit B includes multiple consumables; compare the current kit contents and your onboard spares.

Inspect listing
ZION-AUTO

Z-Ion For Auto System

Confirm with Spectra before ordering.

Optional Z-Ion system; the catalog links only the 24V variant, while the system fact sheet lists Z-Ion compatibility. Confirm voltage-specific kit and installed control generation.

Inspect listing
KIT-HP-20U

20% Clark Pump Upgrade (Org. Cust. Pmp)

Confirm with Spectra before ordering.

Repair-and-return 20% pump service. Confirm core, revision, shipping and service terms.

Inspect listing
KIT-HP-20R

20% Clark Pump Reman. (Core $2,200)

Confirm with Spectra before ordering.

Remanufactured 20% pump exchange. Confirm core, revision and exchange terms.

Inspect listing
EL-SC-CTRBA

Spectra Connect Control Board Assm (Rlb+Cpu)

Confirm with Spectra before ordering.

Connect board assembly needs correct model firmware and installed generation. The source drawing spans four supplies; catalog fitment is limited to two. Confirm before replacing.

Inspect listing
SUB-NP-M2Z-SFHA

Np400 Mk2Z Strainer-Fpm Hose Assem.

Confirm with Spectra before ordering.

Newport 700/1000 inlet pigtail appears on manual page 101, but this catalog title says NP400. Check installed hose and fittings with Spectra.

Inspect listing

REFERENCE LIBRARY

Manuals and drawings

Use the manual revision that matches the installed hardware. This identification guide is not a disassembly procedure.