Overview
Overview
Cartridge length × outside diameter: 10 × 4 inches. Manufacturer nominal length × outside diameter. Nominal size classes may differ from measured end-to-end dimensions.
FT-FTC-CCBB is the commercial solid carbon block cartridge in the freshwater-flush module. Its job is to remove chlorine from the flush supply before that water reaches the reverse-osmosis membranes.
The Farallon Connect drawing identifies this exact cartridge inside the FT-FTH-10BC3P1 flush housing. It has a different job from the 20- and 5-micron seawater prefilters, so replacing those sediment elements does not renew chlorine protection.
Specifications & Contents
Specifications & Contents
| Part number | FT-FTC-CCBB |
|---|---|
| Manufacturer nominal size | 4-inch diameter × 10-inch length |
| Media | Solid carbon block |
| Supplied | One cartridge |
| Circuit | Freshwater flush |
| Farallon service interval | At least every six months |
| Length × outside diameter | 10 × 4 inches; Manufacturer nominal length × outside diameter |
Fits My System
Fits My System
Use the commercial flush-filter housing shown in the installed arrangement. The Farallon manual’s flush assembly drawing uses FT-FTC-CCBB, although its spare-parts table prints FT-FTC-CCBB10. The current manufacturer product page uses FT-FTC-CCBB.
Select your configuration to see its requirements, or open the complete reference below.
All documented configurations and requirements
Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.
Documented configurations
- Aquifer 3000-MIL · Manual · Match installed voltage and hardware
Aquifer 3000-MIL configuration documented by the January 2026 manual; do not transfer to smaller Clark-pump Aquifers.
Documented configurations
- Farallon 1800C · Connect · 220 VAC · Standard / long membranes · FL-1800C-220
- Farallon 2800C · Connect · 220 VAC · Standard / long membranes · FL-2800C-220
Farallon Connect feed/filter/boost/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
FAQs
FAQs
Does clear water flowing through it mean the carbon is still effective?
Appearance and flow do not replace the carbon service interval. The Farallon manual requires replacement at least every six months to maintain flush-water chlorine protection.
Manuals & Resources
Filter Housing Reference
Filter Housing Reference
Identify the housing by its part number before choosing its seal or wrench. This chart compares housing hardware; it does not establish that every cartridge fits every housing.
| Housing | O-ring | Wrench | Identification note |
|---|---|---|---|
| FT-FTH-10L3PCS | SO-FHS-3PCS10 | FT-FHW-3PCS | Three-piece low-pressure housing |
| FT-FTH-10 | SO-FHS-LP10 | FT-FHW-10 | Legacy standard housing and wrench marked discontinued in the chart |
| FT-FTH-10L, FT-FTH-10H, KIT-HPHASSEM | SO-FHS-10H | FT-FHW-10H, FT-FHW-10HSS | Low-pressure, high-pressure and dual high-pressure housings shown in chart |
| FT-FTH-10BC3PC1 | SO-FHS-3PS20BB | FT-FHW-20BB3PCS | Chart code differs from store FT-FTH-10BC3P1; housing identity unresolved |
Spectra filter, housing, seal and wrench chart. The chart’s 10-3/4-inch housing label is not a measured cartridge length. Match cartridge length, outside diameter, media and end seals separately.