Spectra Watermakers

Spectra Watermakers Cruise Kit B KIT-BCK-B

$184.00
Current stock: 0
Item #: KIT-BCK-B
Availability:
Manuals & support

Start with your model’s parts diagram and the number on the installed part. Match any model, controls, voltage, or serial-range notes shown in this listing.

Spectra / Katadyn manufacturer support ↗
Overview

Overview

KIT-BCK-B supplies both sediment-filter ratings used in a two-stage Spectra prefilter arrangement. The 20-micron stage catches coarser particles before the 5-micron stage; the separate carbon cartridge belongs in the freshwater-flush circuit.

Three cartridges of each sediment rating provide stock for three paired changes when the installed arrangement has one housing of each rating. Actual replacement frequency depends on the feed water and the system’s filter indication.

Specifications & Contents

Specifications & Contents

Part numberKIT-BCK-B
20-micron sediment cartridges3
5-micron sediment cartridges3
Carbon / charcoal cartridge1
SC-1 storage chemical2 bags
Fits My System

Fits My System

Identify both the installed cartridge size and the filter ratings. Kit B supplies standard-filter consumables; Farallon systems with commercial Big Blue elements use the differently sized contents of Kit D. The records below show the documented kit recommendations.

Select your configuration to see its requirements, or open the complete reference below.

All documented configurations and requirements

Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.

Documented configurations

  • Newport 1000 Mk II-Z · MPC 5000 · Match installed voltage and hardware
  • Newport 700 Mk II-Z · MPC 5000 · Match installed voltage and hardware

Cruise consumables kit; confirm current kit contents and installed filter stages. Carry-on spares quantity is not system installation quantity.

Parts diagram / guide, page 49

Documented configurations

  • Newport 1000C · Connect · 110 VAC · Standard / long membranes · NP-1000C-110
  • Newport 1000C · Connect · 220 VAC · Standard / long membranes · NP-1000C-220
  • Newport 1000C · Connect · 24 VDC · Standard / long membranes · NP-1000C-24
  • Newport 1000C · Connect · 48 VDC · Standard / long membranes · NP-1000C-48
  • Newport 700C · Connect · 110 VAC · Standard / long membranes · NP-700C-110
  • Newport 700C · Connect · 220 VAC · Standard / long membranes · NP-700C-220
  • Newport 700C · Connect · 24 VDC · Standard / long membranes · NP-700C-24
  • Newport 700C · Connect · 48 VDC · Standard / long membranes · NP-700C-48

Cruise consumables kit; confirm current kit contents and installed filter stages. Carry-on spares quantity is not system installation quantity.

Parts diagram / guide, page 58

Documented configurations

  • Newport 400 Mk II · MPC 5000 · Match installed voltage and hardware

Cruise consumables kit; confirm current kit contents and installed filter stages. Carry-on spares quantity is not system installation quantity.

Parts diagram / guide, page 38

Documented configurations

  • Newport 400 Mk II-Z · MPC 5000 · Match installed voltage and hardware

Cruise consumables kit; confirm current kit contents and installed filter stages. Carry-on spares quantity is not system installation quantity.

Parts diagram / guide, page 45

Documented configurations

  • Newport 400C · Connect · 12 VDC · Compact / short membranes · NP-400C-12S
  • Newport 400C · Connect · 12 VDC · Standard / long membranes · NP-400C-12
  • Newport 400C · Connect · 24 VDC · Compact / short membranes · NP-400C-24S
  • Newport 400C · Connect · 24 VDC · Standard / long membranes · NP-400C-24
  • Newport 400C · Connect · 48 VDC · Compact / short membranes · NP-400C-48S
  • Newport 400C · Connect · 48 VDC · Standard / long membranes · NP-400C-48

Cruise consumables kit; confirm current kit contents and installed filter stages. Carry-on spares quantity is not system installation quantity.

Parts diagram / guide, page 56

Documented configurations

  • Ventura 150 MPC · Match installed voltage and hardware
  • Ventura 200T MPC · Match installed voltage and hardware

Cruise consumables kit; confirm current kit contents and installed filter stages. Carry-on spares quantity is not system installation quantity.

Parts diagram / guide, page 41

Documented configurations

  • Ventura 150C · Connect · 12 VDC · Standard · VT-150C-12V
  • Ventura 150C · Connect · 24 VDC · Standard · VT-150C-24V
  • Ventura 200C · Connect · 12 VDC · Standard · VT-200C-12V
  • Ventura 200C · Connect · 24 VDC · Standard · VT-200C-24V

Cruise consumables kit; confirm current kit contents and installed filter stages. Carry-on spares quantity is not system installation quantity.

Parts diagram / guide, page 52

FAQs

FAQs

Do I install a 20-micron cartridge wherever a 5-micron one fits?

Keep each housing’s specified rating. The two cartridges can share a physical size while providing different filtration; substituting the coarser rating changes what reaches the next stage.

Manuals & Resources
Reviews

Customer reviews

Be the first to review this product.