Overview

FT-FTH-10L3PCS is the three-piece filter housing identified in Spectra’s chart as the MKII low-pressure design. Its separate blue retaining collar secures the clear bowl to the blue head.

The housing is the reusable container around the cartridge. Order its seal and opening wrench by this three-piece design; the older standard housing and the black high-pressure housing use different service parts.

Specifications & Contents

Specifications & Contents

Part numberFT-FTH-10L3PCS
IdentificationClear bowl, separate blue collar/ring nut, blue head
Application designationLow pressure; standard 10-inch filter class
Housing sealSO-FHS-3PCS10
Opening wrenchFT-FHW-3PCS
Mounting bracketNot included in the existing store listing
Fits My System

Fits My System

Match the three-piece body shown in Spectra’s chart and the circuit in the system drawing. For seawater prefilters, Spectra’s selection bulletin calls for a high-pressure housing when the feed pump is upstream; low-pressure housings apply when it is downstream. Flush-circuit housings must follow their own assembly drawing.

Select your configuration to see its requirements, or open the complete reference below.

All documented configurations and requirements

Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.

Documented configurations

  • Bimini 300C · Connect · Match installed voltage and hardware

Bimini feed/filter/strainer/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 82 · Parts diagram / guide, page 85

Documented configurations

  • Cape Horn Extreme 330 · Deluxe · 12 VDC · Compact / short membranes · CH-330-12S
  • Cape Horn Extreme 330 · Deluxe · 12 VDC · Standard / long membranes · CH-330-12
  • Cape Horn Extreme 330 · Deluxe · 24 VDC · Compact / short membranes · CH-330-24S
  • Cape Horn Extreme 330 · Deluxe · 24 VDC · Standard / long membranes · CH-330-24

Cape Horn analog feed A/manual sample module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 51

Documented configurations

  • Cape Horn Extreme 330R · Remote · 12 VDC · Compact / short membranes · CH-330R-12S
  • Cape Horn Extreme 330R · Remote · 12 VDC · Standard / long membranes · CH-330R-12
  • Cape Horn Extreme 330R · Remote · 24 VDC · Compact / short membranes · CH-330R-24S
  • Cape Horn Extreme 330R · Remote · 24 VDC · Standard / long membranes · CH-330R-24

Cape Horn Remote feed A/sample module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 54

Documented configurations

  • Catalina 300 Mk II-Z · MPC 5000 · Match installed voltage and hardware

Catalina 300 Mk II-Z feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 92

Documented configurations

  • Catalina 300 Mk II-Z · MPC 5000 · Match installed voltage and hardware

Catalina 300 Mk II-Z compact pressure-vessel/filter assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires compact membrane arrangement for the illustrated module. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 93

Documented configurations

  • Catalina 340 Z · MPC 5000 · Match installed voltage and hardware

Catalina 340Z feed/boost/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 82 · Parts diagram / guide, page 84

Documented configurations

  • Catalina 340C · Connect · 12 VDC · Compact / short membranes · CT-340C-12S
  • Catalina 340C · Connect · 12 VDC · Standard / long membranes · CT-340C-12
  • Catalina 340C · Connect · 24 VDC · Compact / short membranes · CT-340C-24S
  • Catalina 340C · Connect · 24 VDC · Standard / long membranes · CT-340C-24
  • Catalina 340C · Connect · 48 VDC · Compact / short membranes · CT-340C-48S
  • Catalina 340C · Connect · 48 VDC · Standard / long membranes · CT-340C-48

Catalina Connect filter/boost/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 76 · Parts diagram / guide, page 78

Documented configurations

  • Catalina 340R · Remote · 12 VDC · Compact / short membranes · CT-340RS-12
  • Catalina 340R · Remote · 12 VDC · Standard / long membranes · CT-340R-12
  • Catalina 340R · Remote · 24 VDC · Compact / short membranes · CT-340RS-24
  • Catalina 340R · Remote · 24 VDC · Standard / long membranes · CT-340R-24
  • Catalina 340R · Remote · 48 VDC · Compact / short membranes · CT-340RS-48
  • Catalina 340R · Remote · 48 VDC · Standard / long membranes · CT-340R-48

Catalina Remote feed/filter/boost/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 59 · Parts diagram / guide, page 62

Documented configurations

  • Newport 1000 Mk II · MPC 5000 · Match installed voltage and hardware
  • Newport 700 Mk II · MPC 5000 · Match installed voltage and hardware

Newport 700/1000 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 60 · Parts diagram / guide, page 63

Documented configurations

  • Newport 1000 Mk II-Z · MPC 5000 · Match installed voltage and hardware
  • Newport 700 Mk II-Z · MPC 5000 · Match installed voltage and hardware

Newport 700/1000 Mk II-Z feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 85 · Parts diagram / guide, page 89

Documented configurations

  • Newport 1000C · Connect · 110 VAC · Standard / long membranes · NP-1000C-110
  • Newport 1000C · Connect · 220 VAC · Standard / long membranes · NP-1000C-220
  • Newport 1000C · Connect · 24 VDC · Standard / long membranes · NP-1000C-24
  • Newport 1000C · Connect · 48 VDC · Standard / long membranes · NP-1000C-48
  • Newport 700C · Connect · 110 VAC · Standard / long membranes · NP-700C-110
  • Newport 700C · Connect · 220 VAC · Standard / long membranes · NP-700C-220
  • Newport 700C · Connect · 24 VDC · Standard / long membranes · NP-700C-24
  • Newport 700C · Connect · 48 VDC · Standard / long membranes · NP-700C-48

Newport 700/1000 Connect feed/filter/boost/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 95 · Parts diagram / guide, page 100

Documented configurations

  • Newport 400 Mk II · MPC 5000 · Match installed voltage and hardware

Newport 400 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 59

Documented configurations

  • Newport 400 Mk II-Z · MPC 5000 · Match installed voltage and hardware

Newport 400 Mk II-Z feed/boost/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 80 · Parts diagram / guide, page 81

Documented configurations

  • Newport 400C · Connect · 12 VDC · Compact / short membranes · NP-400C-12S
  • Newport 400C · Connect · 12 VDC · Standard / long membranes · NP-400C-12
  • Newport 400C · Connect · 24 VDC · Compact / short membranes · NP-400C-24S
  • Newport 400C · Connect · 24 VDC · Standard / long membranes · NP-400C-24
  • Newport 400C · Connect · 48 VDC · Compact / short membranes · NP-400C-48S
  • Newport 400C · Connect · 48 VDC · Standard / long membranes · NP-400C-48

Newport 400 Connect feed/filter/boost/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 88 · Parts diagram / guide, page 89 · Parts diagram / guide, page 91

Documented configurations

  • Ventura 150 MPC · Match installed voltage and hardware
  • Ventura 200T MPC · Match installed voltage and hardware

Ventura MPC feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 81

Documented configurations

  • Ventura 150C · Connect · 12 VDC · Standard · VT-150C-12V
  • Ventura 150C · Connect · 24 VDC · Standard · VT-150C-24V
  • Ventura 200C · Connect · 12 VDC · Standard · VT-200C-12V
  • Ventura 200C · Connect · 24 VDC · Standard · VT-200C-24V

Ventura Connect filter/feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 78

Documented configurations

  • Ventura 150D · Deluxe · 12 VDC · Standard · VT-150-D-12V
  • Ventura 150D · Deluxe · 24 VDC · Standard · VT-150-D-24V
  • Ventura 200T · Deluxe · 12 VDC · Standard · VT-200-T-12
  • Ventura 200T · Deluxe · 24 VDC · Standard · VT-200-T-24

Ventura Deluxe feed and manual flush modules. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 51

Documented configurations

  • Ventura 150R · Remote · 12 VDC · Standard · VT-150R-12
  • Ventura 150R · Remote · 24 VDC · Standard · VT-150R-24
  • Ventura 200R-T · Remote · 12 VDC · Standard · VT-200R-T-12
  • Ventura 200R-T · Remote · 24 VDC · Standard · VT-200R-T-24

Ventura Remote feed and flush modules. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.

Parts diagram / guide, page 59

Manuals & Resources
Filter Housing Reference

Filter Housing Reference

Identify the housing by its part number before choosing its seal or wrench. This chart compares housing hardware; it does not establish that every cartridge fits every housing.

HousingO-ringWrenchIdentification note
FT-FTH-10L3PCSSO-FHS-3PCS10FT-FHW-3PCSThree-piece low-pressure housing
FT-FTH-10SO-FHS-LP10FT-FHW-10Legacy standard housing and wrench marked discontinued in the chart
FT-FTH-10L, FT-FTH-10H, KIT-HPHASSEMSO-FHS-10HFT-FHW-10H, FT-FHW-10HSSLow-pressure, high-pressure and dual high-pressure housings shown in chart
FT-FTH-10BC3PC1SO-FHS-3PS20BBFT-FHW-20BB3PCSChart code differs from store FT-FTH-10BC3P1; housing identity unresolved

Spectra filter, housing, seal and wrench chart. The chart’s 10-3/4-inch housing label is not a measured cartridge length. Match cartridge length, outside diameter, media and end seals separately.