Overview
Overview
FT-FTH-10H is the black-bowl, black-head high-pressure filter housing in Spectra’s standard filter range. The bowl has male threads at its top, distinguishing it from the blue-collar three-piece design.
“High pressure” describes this filter-housing application. Spectra’s selection bulletin specifies the high-pressure housing for seawater prefilters located after the feed pump. It is not a membrane pressure vessel.
Specifications & Contents
Specifications & Contents
| Part number | FT-FTH-10H |
|---|---|
| Identification | Black bowl with male threads; black head |
| Filter class | Standard 10-inch housing |
| Matching seal | SO-FHS-10H |
| Matching wrench | FT-FHW-10H |
| Mounting bracket | FT-FHB-10HS, not included in the existing store listing |
Fits My System
Fits My System
Use the installed prefilter assembly’s housing specification. A clear bowl can identify another design even when its cartridge is the same length; compare the housing part number and pressure application in the manufacturer chart.
Select your configuration to see its requirements, or open the complete reference below.
All documented configurations and requirements
Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.
Documented configurations
- Cape Horn Extreme 330 · Deluxe · 12 VDC · Standard / long membranes · CH-330-12
- Cape Horn Extreme 330 · Deluxe · 24 VDC · Standard / long membranes · CH-330-24
Cape Horn standard long pressure-vessel/feed B module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires long membrane arrangement for the illustrated module. Housing is specific to this position; do not move a low-pressure housing to the pressure side.
Documented configurations
- Cape Horn Extreme 330R · Remote · 12 VDC · Standard / long membranes · CH-330R-12
- Cape Horn Extreme 330R · Remote · 24 VDC · Standard / long membranes · CH-330R-24
Cape Horn Remote standard long pressure-vessel/feed B module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires long membrane arrangement for the illustrated module. Housing is specific to this position; do not move a low-pressure housing to the pressure side.
Documented configurations
- Catalina 300 · MPC 5000 · Match installed voltage and hardware
Catalina 300 MPC feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.
Documented configurations
- Monterey 1000 · MPC 3000 · Match installed voltage and hardware
Monterey historical plumbing chapter. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side. Historical pictured module only. Pump internals and electrical variants are not inherited.
Documented configurations
- Newport 400 · MPC 5000 · Match installed voltage and hardware
Newport 400 Mk I MAG feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.
Documented configurations
- Ventura 150 MPC · Match installed voltage and hardware
- Ventura 200T MPC · Match installed voltage and hardware
Ventura MPC feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.
Documented configurations
- Ventura 150C · Connect · 12 VDC · Standard · VT-150C-12V
- Ventura 150C · Connect · 24 VDC · Standard · VT-150C-24V
- Ventura 200C · Connect · 12 VDC · Standard · VT-200C-12V
- Ventura 200C · Connect · 24 VDC · Standard · VT-200C-24V
Ventura Connect filter/feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.
Documented configurations
- Ventura 150D · Deluxe · 12 VDC · Standard · VT-150-D-12V
- Ventura 150D · Deluxe · 24 VDC · Standard · VT-150-D-24V
- Ventura 200T · Deluxe · 12 VDC · Standard · VT-200-T-12
- Ventura 200T · Deluxe · 24 VDC · Standard · VT-200-T-24
Ventura Deluxe feed and manual flush modules. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.
Documented configurations
- Ventura 150R · Remote · 12 VDC · Standard · VT-150R-12
- Ventura 150R · Remote · 24 VDC · Standard · VT-150R-24
- Ventura 200R-T · Remote · 12 VDC · Standard · VT-200R-T-12
- Ventura 200R-T · Remote · 24 VDC · Standard · VT-200R-T-24
Ventura Remote panel/strainer module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Housing is specific to this position; do not move a low-pressure housing to the pressure side.
Manuals & Resources
Filter Housing Reference
Filter Housing Reference
Identify the housing by its part number before choosing its seal or wrench. This chart compares housing hardware; it does not establish that every cartridge fits every housing.
| Housing | O-ring | Wrench | Identification note |
|---|---|---|---|
| FT-FTH-10L3PCS | SO-FHS-3PCS10 | FT-FHW-3PCS | Three-piece low-pressure housing |
| FT-FTH-10 | SO-FHS-LP10 | FT-FHW-10 | Legacy standard housing and wrench marked discontinued in the chart |
| FT-FTH-10L, FT-FTH-10H, KIT-HPHASSEM | SO-FHS-10H | FT-FHW-10H, FT-FHW-10HSS | Low-pressure, high-pressure and dual high-pressure housings shown in chart |
| FT-FTH-10BC3PC1 | SO-FHS-3PS20BB | FT-FHW-20BB3PCS | Chart code differs from store FT-FTH-10BC3P1; housing identity unresolved |
Spectra filter, housing, seal and wrench chart. The chart’s 10-3/4-inch housing label is not a measured cartridge length. Match cartridge length, outside diameter, media and end seals separately.