Overview
Overview
SO-FHS-3PCS10 seals the bowl joint in Spectra’s three-piece low-pressure filter housing, FT-FTH-10L3PCS. It is the O-ring service part, not the housing assembly or a filter cartridge.
Use the separate blue collar and blue head to identify the housing in Spectra’s chart. The discontinued standard clear-bowl housing uses SO-FHS-LP10, while the black-head high/low-pressure group uses SO-FHS-10H.
Specifications & Contents
Specifications & Contents
| Part number | SO-FHS-3PCS10 |
|---|---|
| Documented housing | FT-FTH-10L3PCS |
| Component | Housing sealing O-ring |
Fits My System
Fits My System
Match the three-piece housing itself. A 10-inch cartridge length does not identify the O-ring groove or make the seals for other housing designs interchangeable.
Select your configuration to see its requirements, or open the complete reference below.
All documented configurations and requirements
Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.
Documented configurations
- Bimini 300C · Connect · Match installed voltage and hardware
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Cape Horn Extreme 330 · Deluxe · 12 VDC · Compact / short membranes · CH-330-12S
- Cape Horn Extreme 330 · Deluxe · 12 VDC · Standard / long membranes · CH-330-12
- Cape Horn Extreme 330 · Deluxe · 24 VDC · Compact / short membranes · CH-330-24S
- Cape Horn Extreme 330 · Deluxe · 24 VDC · Standard / long membranes · CH-330-24
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Cape Horn Extreme 330 · Deluxe · 12 VDC · Compact / short membranes · CH-330-12S
- Cape Horn Extreme 330 · Deluxe · 12 VDC · Standard / long membranes · CH-330-12
- Cape Horn Extreme 330 · Deluxe · 24 VDC · Compact / short membranes · CH-330-24S
- Cape Horn Extreme 330 · Deluxe · 24 VDC · Standard / long membranes · CH-330-24
Cape Horn analog feed A/manual sample module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Cape Horn Extreme 330R · Remote · 12 VDC · Compact / short membranes · CH-330R-12S
- Cape Horn Extreme 330R · Remote · 12 VDC · Standard / long membranes · CH-330R-12
- Cape Horn Extreme 330R · Remote · 24 VDC · Compact / short membranes · CH-330R-24S
- Cape Horn Extreme 330R · Remote · 24 VDC · Standard / long membranes · CH-330R-24
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Cape Horn Extreme 330R · Remote · 12 VDC · Compact / short membranes · CH-330R-12S
- Cape Horn Extreme 330R · Remote · 12 VDC · Standard / long membranes · CH-330R-12
- Cape Horn Extreme 330R · Remote · 24 VDC · Compact / short membranes · CH-330R-24S
- Cape Horn Extreme 330R · Remote · 24 VDC · Standard / long membranes · CH-330R-24
Cape Horn Remote feed A/sample module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Catalina 300 Mk II-Z · MPC 5000 · Match installed voltage and hardware
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Catalina 340 Z · MPC 5000 · Match installed voltage and hardware
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Catalina 340C · Connect · 12 VDC · Compact / short membranes · CT-340C-12S
- Catalina 340C · Connect · 12 VDC · Standard / long membranes · CT-340C-12
- Catalina 340C · Connect · 24 VDC · Compact / short membranes · CT-340C-24S
- Catalina 340C · Connect · 24 VDC · Standard / long membranes · CT-340C-24
- Catalina 340C · Connect · 48 VDC · Compact / short membranes · CT-340C-48S
- Catalina 340C · Connect · 48 VDC · Standard / long membranes · CT-340C-48
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Catalina 340R · Remote · 12 VDC · Compact / short membranes · CT-340RS-12
- Catalina 340R · Remote · 12 VDC · Standard / long membranes · CT-340R-12
- Catalina 340R · Remote · 24 VDC · Compact / short membranes · CT-340RS-24
- Catalina 340R · Remote · 24 VDC · Standard / long membranes · CT-340R-24
- Catalina 340R · Remote · 48 VDC · Compact / short membranes · CT-340RS-48
- Catalina 340R · Remote · 48 VDC · Standard / long membranes · CT-340R-48
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Newport 1000 Mk II · MPC 5000 · Match installed voltage and hardware
- Newport 700 Mk II · MPC 5000 · Match installed voltage and hardware
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Newport 1000 Mk II-Z · MPC 5000 · Match installed voltage and hardware
- Newport 700 Mk II-Z · MPC 5000 · Match installed voltage and hardware
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Newport 1000C · Connect · 110 VAC · Standard / long membranes · NP-1000C-110
- Newport 1000C · Connect · 220 VAC · Standard / long membranes · NP-1000C-220
- Newport 1000C · Connect · 24 VDC · Standard / long membranes · NP-1000C-24
- Newport 1000C · Connect · 48 VDC · Standard / long membranes · NP-1000C-48
- Newport 700C · Connect · 110 VAC · Standard / long membranes · NP-700C-110
- Newport 700C · Connect · 220 VAC · Standard / long membranes · NP-700C-220
- Newport 700C · Connect · 24 VDC · Standard / long membranes · NP-700C-24
- Newport 700C · Connect · 48 VDC · Standard / long membranes · NP-700C-48
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Newport 400 Mk II · MPC 5000 · Match installed voltage and hardware
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Newport 400 Mk II-Z · MPC 5000 · Match installed voltage and hardware
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Newport 400C · Connect · 12 VDC · Compact / short membranes · NP-400C-12S
- Newport 400C · Connect · 12 VDC · Standard / long membranes · NP-400C-12
- Newport 400C · Connect · 24 VDC · Compact / short membranes · NP-400C-24S
- Newport 400C · Connect · 24 VDC · Standard / long membranes · NP-400C-24
- Newport 400C · Connect · 48 VDC · Compact / short membranes · NP-400C-48S
- Newport 400C · Connect · 48 VDC · Standard / long membranes · NP-400C-48
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Ventura 150 MPC · Match installed voltage and hardware
- Ventura 200T MPC · Match installed voltage and hardware
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Ventura 150 MPC · Match installed voltage and hardware
- Ventura 200T MPC · Match installed voltage and hardware
Ventura MPC feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Ventura 150C · Connect · 12 VDC · Standard · VT-150C-12V
- Ventura 150C · Connect · 24 VDC · Standard · VT-150C-24V
- Ventura 200C · Connect · 12 VDC · Standard · VT-200C-12V
- Ventura 200C · Connect · 24 VDC · Standard · VT-200C-24V
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Ventura 150C · Connect · 12 VDC · Standard · VT-150C-12V
- Ventura 150C · Connect · 24 VDC · Standard · VT-150C-24V
- Ventura 200C · Connect · 12 VDC · Standard · VT-200C-12V
- Ventura 200C · Connect · 24 VDC · Standard · VT-200C-24V
Ventura Connect filter/feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.
Documented configurations
- Ventura 150D · Deluxe · 12 VDC · Standard · VT-150-D-12V
- Ventura 150D · Deluxe · 24 VDC · Standard · VT-150-D-24V
- Ventura 200T · Deluxe · 12 VDC · Standard · VT-200-T-12
- Ventura 200T · Deluxe · 24 VDC · Standard · VT-200-T-24
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Documented configurations
- Ventura 150R · Remote · 12 VDC · Standard · VT-150R-12
- Ventura 150R · Remote · 24 VDC · Standard · VT-150R-24
- Ventura 200R-T · Remote · 12 VDC · Standard · VT-200R-T-12
- Ventura 200R-T · Remote · 24 VDC · Standard · VT-200R-T-24
For the documented original configuration; match installed filter stages, housing and strainer dimensions if modified. Confirm the quantity needed for your repair.
Manuals & Resources
Manuals & Resources
Filter Housing Reference
Filter Housing Reference
Identify the housing by its part number before choosing its seal or wrench. This chart compares housing hardware; it does not establish that every cartridge fits every housing.
| Housing | O-ring | Wrench | Identification note |
|---|---|---|---|
| FT-FTH-10L3PCS | SO-FHS-3PCS10 | FT-FHW-3PCS | Three-piece low-pressure housing |
| FT-FTH-10 | SO-FHS-LP10 | FT-FHW-10 | Legacy standard housing and wrench marked discontinued in the chart |
| FT-FTH-10L, FT-FTH-10H, KIT-HPHASSEM | SO-FHS-10H | FT-FHW-10H, FT-FHW-10HSS | Low-pressure, high-pressure and dual high-pressure housings shown in chart |
| FT-FTH-10BC3PC1 | SO-FHS-3PS20BB | FT-FHW-20BB3PCS | Chart code differs from store FT-FTH-10BC3P1; housing identity unresolved |
Spectra filter, housing, seal and wrench chart. The chart’s 10-3/4-inch housing label is not a measured cartridge length. Match cartridge length, outside diameter, media and end seals separately.