Spectra Watermakers

Spectra Watermakers Newport 400 MKII-Z Motor 24V EL-MTR-1/2HP24

$0.00
Current stock: 0
Item #: EL-MTR-1/2HP24
Availability:
Manuals & support

Start with your model’s parts diagram and the number on the installed part. Match any model, controls, voltage, or serial-range notes shown in this listing.

Spectra / Katadyn manufacturer support ↗
Overview

Overview

EL-MTR-1/2HP24 is the earlier 24V, half-horsepower Leeson motor used in Newport 400 feed-pump modules. It drives the separately identified vane pump.

Spectra identifies this motor as permanently discontinued. The Newport 400C manual specifies EL-MTR-1/2HP12 as the replacement for affected older 24V systems, with adjustment of the PWM controller output for high, low and flush operation.

A 12V replacement in this application requires the manufacturer’s conversion procedure; matching the boat’s 24V supply alone does not identify the correct motor.

Specifications & Contents

Specifications & Contents

Part numberEL-MTR-1/2HP24
Original motor24V DC; 1/2 HP; 2,000 RPM
Frame / enclosure48YC / TEFC
Replacement pathEL-MTR-1/2HP12 with PWM adjustment
Fits My System

Fits My System

A 12V replacement in this application requires the manufacturer’s conversion procedure; matching the boat’s 24V supply alone does not identify the correct motor.

Select your configuration to see its requirements, or open the complete reference below.

All documented configurations and requirements

Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.

Documented configurations

  • Newport 400 Mk II · MPC 5000 · Match installed voltage and hardware

Original 24V half-horsepower, 2000 RPM, 48YC motor configuration. A later 24-to-12V retrofit requires conversion and controller setup; do not select by vessel input alone. System input: 24 V; retain the specified component supply and wiring.

Parts diagram / guide, page 61

Documented configurations

  • Newport 400 Mk II-Z · MPC 5000 · Match installed voltage and hardware

Original 24V half-horsepower, 2000 RPM, 48YC motor configuration. A later 24-to-12V retrofit requires conversion and controller setup; do not select by vessel input alone. System input: 24 V; retain the specified component supply and wiring.

Parts diagram / guide, page 80

Manuals & Resources
Reviews

Customer reviews

Be the first to review this product.