Overview

Overview

PL-ACC-TK is the pressure accumulator used in the feed-water line. Its air bladder cushions the pressure spikes caused by Clark Pump cycling, and a Schrader valve provides the air-charge connection.

Spectra’s Ventura Deluxe bulletin locates it between the prefilters and Clark Pump. The Ventura bulletin gives approximately 65 PSI precharge guidance, while the Newport 400 Connect bulletin gives approximately 60 PSI. These are model-specific reference values, not a universal setting or a tank pressure rating. Use the manual for the installed system and revision.

Specifications & Contents

Specifications & Contents

Part numberPL-ACC-TK
FunctionDampens feed-line pressure pulsations
Air connectionSchrader valve
Ventura Deluxe referenceApproximately 65 PSI (4.5 bar) precharge
Newport 400 Connect referenceApproximately 60 PSI (4.1 bar) precharge
Tank capacity / maximum ratingNot verified
Fits My System

Fits My System

Select the installed model’s accumulator instructions. A shared part number does not make the precharge values identical between systems.

Select your configuration to see its requirements, or open the complete reference below.

All documented configurations and requirements

Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.

Documented configurations

  • Bimini 300C · Connect · Match installed voltage and hardware

Bimini standard pressure-vessel module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires long membrane arrangement for the illustrated module.

Parts diagram / guide, page 81

Documented configurations

  • Cape Horn Extreme 330 · Deluxe · 12 VDC · Standard / long membranes · CH-330-12
  • Cape Horn Extreme 330 · Deluxe · 24 VDC · Standard / long membranes · CH-330-24

Cape Horn standard long pressure-vessel/feed B module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires long membrane arrangement for the illustrated module.

Parts diagram / guide, page 53

Documented configurations

  • Cape Horn Extreme 330R · Remote · 12 VDC · Standard / long membranes · CH-330R-12
  • Cape Horn Extreme 330R · Remote · 24 VDC · Standard / long membranes · CH-330R-24

Cape Horn Remote standard long pressure-vessel/feed B module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires long membrane arrangement for the illustrated module.

Parts diagram / guide, page 57

Documented configurations

  • Catalina 300 Deluxe · Match installed voltage and hardware

Catalina 300 Deluxe historical module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Deluxe controls only; does not inherit automated MPC or Connect components.

Parts diagram / guide, page 69

Documented configurations

  • Catalina 300 Mk II-Z · MPC 5000 · Match installed voltage and hardware

Catalina 300 Mk II-Z feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Parts diagram / guide, page 91 · Parts diagram / guide, page 92

Documented configurations

  • Catalina 300 · MPC 5000 · Match installed voltage and hardware

Catalina 300 MPC feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Parts diagram / guide, page 56 · Parts diagram / guide, page 57

Documented configurations

  • Catalina 340 Z · MPC 5000 · Match installed voltage and hardware

Catalina 340Z long pressure-vessel module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires long membrane arrangement for the illustrated module.

Parts diagram / guide, page 81

Documented configurations

  • Catalina 340C · Connect · 12 VDC · Compact / short membranes · CT-340C-12S
  • Catalina 340C · Connect · 24 VDC · Compact / short membranes · CT-340C-24S
  • Catalina 340C · Connect · 48 VDC · Compact / short membranes · CT-340C-48S

Catalina Connect compact pressure-vessel module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires compact membrane arrangement for the illustrated module.

Parts diagram / guide, page 75

Documented configurations

  • Catalina 340C · Connect · 12 VDC · Standard / long membranes · CT-340C-12
  • Catalina 340C · Connect · 24 VDC · Standard / long membranes · CT-340C-24
  • Catalina 340C · Connect · 48 VDC · Standard / long membranes · CT-340C-48

Catalina Connect standard pressure-vessel module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires long membrane arrangement for the illustrated module.

Parts diagram / guide, page 74

Documented configurations

  • Catalina 340R · Remote · 12 VDC · Standard / long membranes · CT-340R-12
  • Catalina 340R · Remote · 24 VDC · Standard / long membranes · CT-340R-24
  • Catalina 340R · Remote · 48 VDC · Standard / long membranes · CT-340R-48

Catalina Remote standard pressure-vessel module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires long membrane arrangement for the illustrated module.

Parts diagram / guide, page 58

Documented configurations

  • Gulfstream 400 · Auto panel / MPC era predecessor · Match installed voltage and hardware

Gulfstream 400 historical plumbing chapter. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Historical pictured module only. Manual and automatic valves, pump ratio and controls remain separate.

Parts diagram / guide, page 89 · Parts diagram / guide, page 91

Documented configurations

  • Newport 400 Mk II · MPC 5000 · Match installed voltage and hardware

Newport 400 Mk II feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Parts diagram / guide, page 60

Documented configurations

  • Newport 400 Mk II-Z · MPC 5000 · Match installed voltage and hardware

Newport 400 Mk II-Z feed/boost/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Parts diagram / guide, page 81

Documented configurations

  • Newport 400 Mk II-Z · MPC 5000 · Match installed voltage and hardware

Newport 400 Mk II-Z pressure-vessel module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Layout-specific rigid tubes excluded until standard/compact shape is resolved.

Parts diagram / guide, page 79

Documented configurations

  • Newport 400 · MPC 5000 · Match installed voltage and hardware

Newport 400 Mk I MAG feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Parts diagram / guide, page 57

Documented configurations

  • Newport 400C · Connect · 12 VDC · Standard / long membranes · NP-400C-12
  • Newport 400C · Connect · 24 VDC · Standard / long membranes · NP-400C-24
  • Newport 400C · Connect · 48 VDC · Standard / long membranes · NP-400C-48

Newport 400 Connect standard pressure-vessel module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Requires long membrane arrangement for the illustrated module.

Parts diagram / guide, page 86 · Parts diagram / guide, page 87

Documented configurations

  • Santa Cruz · Manual panel · Match installed voltage and hardware

Santa Cruz historical plumbing chapter. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Historical pictured module only. Obsolete generic filter housing replacement remains unresolved.

Parts diagram / guide, page 84

Documented configurations

  • Ventura 150 MPC · Match installed voltage and hardware
  • Ventura 200T MPC · Match installed voltage and hardware

Ventura MPC feed/flush/diversion plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Parts diagram / guide, page 78

Documented configurations

  • Ventura 150C · Connect · 12 VDC · Standard · VT-150C-12V
  • Ventura 150C · Connect · 24 VDC · Standard · VT-150C-24V
  • Ventura 200C · Connect · 12 VDC · Standard · VT-200C-12V
  • Ventura 200C · Connect · 24 VDC · Standard · VT-200C-24V

Ventura Connect filter/feed/flush plumbing. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Parts diagram / guide, page 75

Documented configurations

  • Ventura 150D · Deluxe · 12 VDC · Standard · VT-150-D-12V
  • Ventura 150D · Deluxe · 24 VDC · Standard · VT-150-D-24V
  • Ventura 200T · Deluxe · 12 VDC · Standard · VT-200-T-12
  • Ventura 200T · Deluxe · 24 VDC · Standard · VT-200-T-24

Ventura sample/strainer/accumulator assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Parts diagram / guide, page 52

Documented configurations

  • Ventura 150R · Remote · 12 VDC · Standard · VT-150R-12
  • Ventura 150R · Remote · 24 VDC · Standard · VT-150R-24
  • Ventura 200R-T · Remote · 12 VDC · Standard · VT-200R-T-12
  • Ventura 200R-T · Remote · 24 VDC · Standard · VT-200R-T-24

Ventura Remote panel/strainer module. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only.

Parts diagram / guide, page 61

Manuals & Resources