Overview
Overview
EL-SSR-150 is the 150 PSI pressure transducer identified by the CP2-130 marking in Spectra’s parts manual. It provides feed-pressure information used by the controls and high-pressure alarm logic.
The manual shows red and green identification bands on the two Ventura sensor positions, and a red-band sensor in the Catalina and Newport 400 examples. Use the marking, range and installation position together.
The yellow-band absolute-pressure sensor and 250 PSI transducer have different numbers and functions. A pressure reading or alarm alone does not establish which component needs replacement.
Specifications & Contents
Specifications & Contents
| Part number | EL-SSR-150 |
|---|---|
| Manufacturer range designation | 150 PSI |
| Identification marking | CP2-130 |
| Documented function | Feed-pressure measurement |
Fits My System
Fits My System
The yellow-band absolute-pressure sensor and 250 PSI transducer have different numbers and functions. A pressure reading or alarm alone does not establish which component needs replacement.
Select your configuration to see its requirements, or open the complete reference below.
All documented configurations and requirements
Each group applies only to the listed configurations and installed hardware. Match the conditions and manufacturer references before ordering.
Documented configurations
- Bimini 300C · Connect · Match installed voltage and hardware
documented Connect sensor/diversion assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match the sensor range, connector and manifold position. Component voltage can differ from system input; use the documented control supply.
Documented configurations
- Catalina 300 Mk II-Z · MPC 5000 · Match installed voltage and hardware
legacy pressure-sensor assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match sensor range and installed legacy connector; no automatic modern control conversion.
Documented configurations
- Catalina 300 · MPC 5000 · Match installed voltage and hardware
item in the identified generation and enclosure. Match switch poles/terminals, boot or enclosure dimensions, and instrument range/connection as applicable. A similar label on another control generation is not a substitution.
Documented configurations
- Catalina 340 Z · MPC 5000 · Match installed voltage and hardware
legacy pressure-sensor assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match sensor range and installed legacy connector; no automatic modern control conversion.
Documented configurations
- Catalina 340C · Connect · 12 VDC · Compact / short membranes · CT-340C-12S
- Catalina 340C · Connect · 12 VDC · Standard / long membranes · CT-340C-12
- Catalina 340C · Connect · 24 VDC · Compact / short membranes · CT-340C-24S
- Catalina 340C · Connect · 24 VDC · Standard / long membranes · CT-340C-24
- Catalina 340C · Connect · 48 VDC · Compact / short membranes · CT-340C-48S
- Catalina 340C · Connect · 48 VDC · Standard / long membranes · CT-340C-48
documented Connect sensor/diversion assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match the sensor range, connector and manifold position. Component voltage can differ from system input; use the documented control supply.
Documented configurations
- Farallon 1800C · Connect · 220 VAC · Standard / long membranes · FL-1800C-220
- Farallon 2800C · Connect · 220 VAC · Standard / long membranes · FL-2800C-220
Farallon Connect flow and pressure sensors. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Farallon 4 GPM flow sensor is not the lower-flow marine IFM variant.
Documented configurations
- Newport 400 Mk II-Z · MPC 5000 · Match installed voltage and hardware
legacy pressure-sensor assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match sensor range and installed legacy connector; no automatic modern control conversion.
Documented configurations
- Newport 400 · MPC 5000 · Match installed voltage and hardware
item in the identified generation and enclosure. Match switch poles/terminals, boot or enclosure dimensions, and instrument range/connection as applicable. A similar label on another control generation is not a substitution.
Documented configurations
- Newport 400C · Connect · 12 VDC · Compact / short membranes · NP-400C-12S
- Newport 400C · Connect · 12 VDC · Standard / long membranes · NP-400C-12
- Newport 400C · Connect · 24 VDC · Compact / short membranes · NP-400C-24S
- Newport 400C · Connect · 24 VDC · Standard / long membranes · NP-400C-24
- Newport 400C · Connect · 48 VDC · Compact / short membranes · NP-400C-48S
- Newport 400C · Connect · 48 VDC · Standard / long membranes · NP-400C-48
documented Connect sensor/diversion assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match the sensor range, connector and manifold position. Component voltage can differ from system input; use the documented control supply.
Documented configurations
- Ventura 150 MPC · Match installed voltage and hardware
- Ventura 200T MPC · Match installed voltage and hardware
legacy pressure-sensor assembly. Match installed assembly, port/thread or tube dimensions, material and pressure duty; documented original arrangement only. Match sensor range and installed legacy connector; no automatic modern control conversion.